968 research outputs found

    Higgs domain walls in the thermal background

    Full text link
    Most cosmological models predict that the universe was hot and dense at the early stages of it's evolution. In this paper we analyse the influence of the thermal bath of Standard Model particles on the dynamics of cosmological Higgs domain walls. This manuscript poses an~extension of our earlier work in which we investigated the evolution of networks of Higgs domain walls neglecting the impact of temperature variation. Using the thermally corrected effective potential of Standard Model we have found that both the position of the local maximum hmaxh_{max} separating minima and the width of domain walls strongly depend on temperature TT. For temperatures higher than 1010  GeV10^{10}\; \textrm{GeV} they respectively increase proportionally and decrease inverse proportionally to the increasing temperature. Thus, the energy scale of the problem follows the value of temperature. Our numerical lattice simulations based on the PRS algorithm reveal that Higgs domain walls in the presence of the background thermal bath are highly unstable and decay shortly after formation. Moreover we have found that the fraction of horizons produced by inflation in which Higgs field expectation value is higher then hmaxh_{max} needs to be very low in order for the evolution of the~network of the domain walls to end in the electroweak vacuum. This means that Higgs domain walls necessarily were very rare objects and their average energy density was very small. As a result, the domain walls can not significantly effect cosmological observables

    METODY POMIARU MAŁYCH POJEMNOŚCI W ELEKTRYCZNEJ TOMOGRAFII POJEMNOŚCIOWEJ

    Get PDF
    The paper presents the main methods of small capacitance measurement used in electrical capacitance tomography: the AC method with a sine wave excitation and the charge-discharge method with square wave excitation. Construction of synchronous detector for both circuits was discussed. A modified "charge-discharge" method was presented.W artykule przedstawiono główne metody pomiaru małych pojemności stosowane w elektrycznej tomografii pojemnościowej: metodę częstotliwościową z pobudzeniem za pomocą fali sinusoidalnej oraz metodę „ładuj-rozładuj” z pobudzeniem za pomocą fali prostokątnej. Przedstawiono budowę detektora synchronicznego dla obu układów. Zaprezentowano również modyfikację metody „ładuj-rozładuj”

    ROZWÓJ KONSTRUKCJI ELEKTRYCZNEGO TOMOGRAFU POJEMNOŚCIOWEGO W ZAKŁADZIE ELEKTRONIKI JĄDROWEJ I MEDYCZNEJ

    Get PDF
    Electrical Capacitance Tomography is a technique which allows to visualize a  spatial distribution of electric permittivity in an examined volume. ECT allows to achieve hundreds of frames per second which is suitable for the industrial application, e.g. monitoring of multiphase flows or material mixing. Construction of such ECT system which enables precise data acquisition with sufficient speed  is a challenge. In the Division of Nuclear and Medical Electronics ECT systems which have found applications in many research facilities in Poland and all over the world have been constructed for over 15 years. In this article a multichannel ET3 tomograph and its successor,EVT4, are presented. EVT4 will allow to obtain more than 10 thousand frames per second. This will allow to make progress in studies of dynamic processes and 3D visualization.Elektryczna tomografia pojemnościowa pozwala na obrazowanie przestrzennego rozkładu przenikalności elektrycznej w badanej objętości. Technika ta pozwala na uzyskanie setek obrazów na sekundę, dzięki czemu istnieje możliwość wykorzystania jej w przemyśle, na przykład do monitorowania procesów dynamicznych, takich jak przepływy wielofazowe lub mieszanie materiałów. Skonstruowanie systemu tomograficznego pozwalającego na bardzo szybką akwizycję obrazów o dobrej jakości jest jednak dużym wyzwaniem. W Zakładzie Elektroniki Jądrowej i Medycznej Politechniki Warszawskiej od lat powstają konstrukcje tomografów pojemnościowych, które znajdowały zastosowanie w placówkach naukowych w Polsce i na świecie. W tym artykule prezentowany jest wielokanałowy tomograf ET3 oraz jego następca, EVT4, który pozwoli na uzyskiwanie 10 tysięcy obrazów na sekundę. Pozwoli to na dokładniejsze badanie procesów dynamicznych oraz wizualizację trójwymiarową

    Role i stanowiska pracy w otwartej nauce i komunikacji naukowej. Analiza zakresów obowiązków i próba prognozy przyszłych tendencji zmian w zawodzie

    Get PDF
    During the past two-decades academic libraries updated current staff job responsibilities or created brand new roles. This allowed them to adapt to scholarly communication developments and consequently enabled them to offer efficient servicesto their users. The global calls for openly accessible research results has shifted the institutional, national and international focus and their constant evolvement has required the creation of new research positions in academic libraries. This study reports on the findings of an analysis of job descriptions in the open research services as advertised by UK academic libraries.Technologiczny postęp ostatnich 20 lat zmusił biblioteki akademickie do uaktualnienia bieżących zakresów obowiązków i odpowiedzialności swoich pracowników oraz do wyznaczenia bibliotekarzom całkowicie nowych ról. Pozwoliło im to jednak zaadaptować się do dynamicznego rozwoju i postępu w komunikacji naukowej, a w konsekwencji umożliwiło przedstawienie swoim użytkownikom oferty kompetentnie i sprawnie wykonywanych usług. Globalne wezwania do otwartego dostępu do wyników badań naukowych, zainteresowanie udostępnianiem instytucjonalnym, ogólnokrajowym czy międzynarodowym, nieustająca ewolucja i rozwój związanych z tym usług wymusiły potrzebę stworzenia w bibliotekach akademickich nowych stanowisk badawczych. Artykuł przedstawia wyniki badań zakresów obowiązków nowych stanowisk bibliotecznych w usługach otwartej nauki na podstawie ofert pracy zamieszczanych przez biblioteki akademickie w Zjednoczonym Królestwie

    Neocytoliza - nowy, niedoceniany mechanizm niedokrwistości i wahań stężenia hemoglobiny u chorych z przewlekłą chorobą nerek?

    Get PDF
    Tradycyjne pojmowanie roli erytropoetyny (EPO) w procesie regulacji liczby erytrocytów opiera się na działaniu tego hormonu na etapie tworzenia erytrocytów - późniejsze losy elementów układu czerwonokrwinkowego od czasu, gdy tracą one receptory dla tego hormonu, są od niego niezależne. Opisanie zjawiska redukcji liczby erytrocytów u osób, które znalazły się w stanie nieważkości podczas lotów kosmicznych oraz w trakcie szybkiej adaptacji po zejściu z wysokich gór, umożliwiło zidentyfikowanie zjawiska hemolizy młodych, dojrzewających i nieposiadających receptorów dla EPO form linii erytroblastycznej (neocytolizy). Okazało się, że proces ten jest także zależny od EPO - jej spadające stężenie powoduje uruchomienie hemolizy "neocytów" przez układ siateczkowo-śródbłonkowy na etapie ich ostatecznego dojrzewania, pozostając bez wpływu na hemolizę fizjologiczną (erytrocytów liczących ok. 120 dni). Niewykluczone, że gwałtowny spadek stężenia EPO podczas leczenia krótkodziałającymi preparatami ESA u chorych na przewlekłą chorobę nerek może wyzwalać powtarzalne epizody neocytolizy, co może być jedną z przyczyn suboptymalnych wyników osiąganych przy leczeniu niedokrwistości nerkowopochodnej. Forum Nefrologiczne 2010, tom 3, nr 4, 305-31

    Beyond Grids: Exploring Elastic Input Sampling for Vision Transformers

    Full text link
    Vision transformers have excelled in various computer vision tasks but mostly rely on rigid input sampling using a fixed-size grid of patches. This limits their applicability in real-world problems, such as in the field of robotics and UAVs, where one can utilize higher input elasticity to boost model performance and efficiency. Our paper addresses this limitation by formalizing the concept of input elasticity for vision transformers and introducing an evaluation protocol, including dedicated metrics for measuring input elasticity. Moreover, we propose modifications to the transformer architecture and training regime, which increase its elasticity. Through extensive experimentation, we spotlight opportunities and challenges associated with input sampling strategies
    corecore