    Rationale and design of a randomized trial to assess the safety and efficacy of MultiPoint Pacing (MPP) in cardiac resynchronization therapy: The MPP Trial

    No full text
    BACKGROUND: Although the majority of Class III congestive heart failure (HF) patients treated with cardiac resynchronization therapy (CRT) show a clinical benefit, up to 40% of patients do not respond to CRT. This paper reports the design of the MultiPoint Pacing (MPP) trial, a prospective, randomized, double-blind, controlled study to evaluate the safety and efficacy of CRT using MPP compared to standard biventricular (Bi-V) pacing. METHODS: A maximum of 506 patients with a standard CRT-D indication will be enrolled at up to 50 US centers. All patients will be implanted with a CRT-D system (Quartet LV lead Model 1458Q with a Quadra CRT-D, Abbott) that can deliver both MPP and Bi-V pacing. Standard Bi-V pacing will be activated at implant. At 3 months postimplant, patients in whom the echocardiographic parameters during MPP are equal or better than during Bi-V pacing are randomized (1:1) to either an MPP or Bi-V arm. RESULTS: The primary safety endpoint is freedom from system-related complications at 9 months. Each patient\u27s response to CRT will be evaluated using a heart-failure clinical composite score, consisting of a change in NYHA functional class, patient global assessment score, HF events, and cardiovascular death. The primary efficacy endpoint is the proportion of responders in the MPP arm compared with the Bi-V arm between 3 and 9 months. CONCLUSION: This trial seeks to evaluate whether MPP via a single quadripolar LV lead improves hemodynamic and clinical responses to CRT, both in clinical responders and nonresponders

    102-03: Safety and efficacy of multipoint pacing in cardiac resynchronization therapy: the multipoint pacing (MPP) IDE study

    No full text
    Purpose: The MultiPoint™ (MPP) Pacing IDE Study assessed the safety and efficacy of the MPP feature in heart failure (HF) patients indicated for a cardiac resynchronization therapy defibrillator (CRT-D). Methods: This multicenter study enrolled and followed 506 patients with a standard CRT-D indication who were implanted with a CRT-D system (Quartet™ LV lead Model 1458Q with a Quadra CRT-D, St. Jude Medical) capable of delivering either Quadripolar Bi-Ventricular (Bi-V) pacing or MPP. Quadripolar Bi-V pacing was activated at implant. At 3 months post-implant, patients\u27 responder status was assessed, both responders and non-responders were randomized, and 1:1 randomization (Bi-V or MPP) was stratified by the patient\u27s responder status (Defined by the Clinical Composite Score). The primary safety end point was freedom from system-related complications through 9 months. The primary efficacy end point was non-inferiority of the proportion of non-responders in the MPP arm compared with the Bi-V arm between 3 and 9 months. Results: The CRT-D system was successfully implanted in 455 of the 469 attempts (97%). 381 patients were randomized to either Bi-V (n = 180) or MPP (n = 201) at 3 months. Baseline characteristics for both arms were comparable. The primary safety end point (93.2%, 97.5% lower confidence bound 90.4%) was greater than the objective performance criterion of 75% and therefore met. The primary efficacy end point was met for both intention-to-treat (ITT) and As-treated populations in 381 randomized patients (ITT, p = 0.013 and As-treated, p = 0.008, respectively). For patients (n = 52) in the MPP arm programmed with wide cathode spacing (≥ 30 mm) and the shortest intraventricular timing delay (5 ms), MPP provided significantly higher clinical responder rate up to 87% (Fig A, p = 0.003 vs. \u3c 30 mm) and converted 100% of non-responders to responders (Fig B, p = 0.006 vs. \u3c 30 mm). Conclusion: MPP was shown to be safe and effective and the study met the pre-specified hypothesis that the response to MPP is non-inferior to Quadripolar Bi-V pacing. When MPP was programmed with cathode spacing \u3e 30 mm and 5 ms LV delay, the CRT response was greatest (87%) and all non-responders were converted to responders. View largeDownload slid

    Left ventricular enlargement, cardiac resynchronization therapy efficacy, and impact of MultiPoint pacing

    No full text
    BACKGROUND: Left ventricular (LV) epicardial pacing results in slowly propagating paced wavefronts. We postulated that this effect might limit cardiac resynchronization therapy efficacy in patients with LV enlargement using conventional biventricular pacing with single-site LV pacing, but be mitigated by LV stimulation from 2 widely spaced sites using MultiPoint pacing with wide anatomic separation (MPP-AS: ≥30 mm). We tested this hypothesis in the multicenter randomized MPP investigational device exemption trial. METHODS: Following implant, quadripolar biventricular single-site pacing was activated in all patients (n=506). From 3 to 9 months postimplant, among patients with available baseline LV end-diastolic volume (LVEDV) measures, 188 received biventricular single-site pacing and 43 received MPP-AS. Patients were dichotomized by median baseline LVEDV indexed to height (LVEDVIMedian). Outcomes were measured by the clinical composite score (primary efficacy end point), quality of life, LV structural remodeling (↑EF \u3e5% and ↓ESV 10%) and heart failure event/cardiovascular death. RESULTS: LVEDVIMedian was 1.1 mL/cm. Baseline characteristics differed in patients with LVEDVI\u3eMedian versus LVEDVI≤Median. Among patients with LVEDVI\u3eMedian, biventricular single-site pacing was less efficacious compared to patients with LVEDVI≤Median (clinical composite score, 65% versus 79%). In contrast, MPP-AS programming generated greater clinical composite score response (92% versus 65%, P=0.023) and improved quality of life (-31.0±29.7 versus -15.7±22.1, P=0.038) versus biventricular single-site pacing in patients with LVEDVI\u3eMedian. Reverse remodeling trended better with MPP-AS programming. In patients with LVEDVI\u3eMedian, heart failure event rate increased following the 3-month randomization point with biventricular single-site pacing (0.0150±0.1725 in LVEDVI\u3eMedian versus -0.0190±0.0808 in LVEDVI ≤Median, P=0.012), but no heart failure event occurred in patients with MPP-AS programming between 3 and 9 months in LVEDVI\u3eMedian. All measured outcomes did not differ in patients receiving MPP-AS and biventricular single-site pacing with LVEDVI≤Median. CONCLUSIONS: Conventional biventricular single-site pacing, even with a quadripolar lead, has reduced efficacy in patients with LV enlargement. However, the greatest response rate in patients with larger hearts was observed when programmed to MPP-AS pacing

    Ventricular tachycardias arising from the aortic sinus of valsalva: an under-recognized variant of left outflow tract ventricular tachycardia

    Get PDF
    AbstractOBJECTIVESTo describe a normal heart left bundle branch block, inferior axis ventricular tachycardia (VT), that could not be ablated from the right or left ventricular outflow tracts.BACKGROUNDWhether these VTs are epicardial and can be identified by a specific electrocardiographic pattern is unclear.METHODSTwelve patients with normal heart left bundle branch block, inferior axis VT and previously failed ablation were included in this study. Together with mapping in the right and left ventricular outflow tracts, we obtained percutaneous epicardial mapping in the first five patients and performed aortic sinus of Valsalva mapping in all patients.RESULTSNo adequate pace mapping was observed in the right and left ventricular outflow tracts. Earliest ventricular activation was noted in the epicardium and the aortic cusps. All patients were successfully ablated from the aortic sinuses of Valsalva (95% CI 0% to 18%). The electrocardiographic pattern associated with this VT was left bundle branch block, inferior axis and early precordial transition with Rs or R in V2or V3. Ventricular tachycardia from the left sinus had rS pattern in lead I, and VT from the noncoronary sinus had a notched R wave in lead I. None of the patients had complications and all remained arrhythmia-free at a mean follow-up of 8 ± 2.6 months.CONCLUSIONSNormal heart VT with left bundle branch block, inferior axis and early precordial transition can be ablated in the majority of patients from either the left or the noncoronary aortic sinus of Valsalva

    The rationale and design of the SMART CRT trial

    Full text link
    AIMS The SMART CRT study will assess the efficacy of an atrioventricular optimization algorithm to improve reverse remodeling among patients undergoing cardiac resynchronization therapy (CRT) in the presence of interventricular electrical delay. METHODS AND RESULTS The SMART CRT study is a global, multicenter, prospective, randomized study of patients undergoing CRT implantation. The primary endpoint of this trial is response rate to CRT, defined as decrease in left ventricular end-systolic volume (LVESV) ≥15% at 6 months compared to preimplant baseline. Additional prespecified analyses are: (1) clinical composite endpoint combining all-cause mortality, heart failure events, New York Heart Association class, and Quality of Life (using a patient global assessment instrument); (2) the individual components of the clinical composite endpoint; (3) 6-minute walk distance; (4) Kansas City Cardiomyopathy Questionnaire; (5) LVESV as a continuous variable; and (6) absolute left-ventricular ejection fraction. Subjects with intraventricular delay ≥ 70 ms measured between the right ventricular and left ventricular pacing leads will be randomized in a 1:1 ratio to have either an AV Delay and pacing chamber determined by SmartDelay™ or a Fixed AV Delay of 120 ms with biventricular pacing. Enrollment of an estimated 726 of subjects from up to 100 centers worldwide is planned to achieve 436 randomized subjects and 370 complete data sets required to power the primary endpoint. CONCLUSIONS This trial will provide important data regarding the importance of AV Delay programming in patients with prolonged interventricular delay at the pacing sites

    Additional electrodes on the Quartet™ LV lead provide more programmable pacing options than bipolar and tripolar equivalents

    Get PDF
    International audienceAIMS: The aim of this study was to evaluate any benefits to the number of viable pacing vectors and maximal spatial coverage with quadripolar left ventricular (LV) leads when compared with tripolar and bipolar equivalents in patients receiving cardiac resynchronization therapy (CRT). METHODS AND RESULTS: A meta-analysis of five previously published clinical trials involving the Quartet™ LV lead (St Jude Medical, St Paul, MN, USA) was performed to evaluate the number of viable pacing vectors defined as capture thresholds ≤2.5 V and no phrenic nerve stimulation and maximal spatial coverage of viable vectors in CRT patients at pre-discharge (n = 370) and first follow-up (n = 355). Bipolar and tripolar lead configurations were modelled by systematic elimination of two and one electrode(s), respectively, from the Quartet lead. The Quartet lead with its four pacing electrodes exhibited the greatest number of pacing vectors per patient when compared with the best bipolar and the best tripolar modelled equivalents. Similarly, the Quartet lead provided the highest spatial coverage in terms of the distance between two furthest viable pacing cathodes when compared with the best bipolar and the best tripolar configurations (P \textless 0.05). Among the three modelled bipolar configurations, the lead configuration with the two most distal electrodes resulted in the highest number of viable pacing vectors. Among the four modelled tripolar configurations, elimination of the second proximal electrode (M3) resulted in the highest number of viable pacing options per patient. There were no significant differences observed between pre-discharge and first follow-up analyses. CONCLUSION: The Quartet lead with its four electrodes and the capability to pace from four anatomical locations provided the highest number of viable pacing vectors at pre-discharge and first follow-up visits, providing more flexibility in device programming and enabling continuation of CRT in more patients when compared with bipolar and tripolar equivalent

    Multicentre safety of adding Focal Impulse and Rotor Modulation (FIRM) to conventional ablation for atrial fibrillation

    No full text
    Aims Focal Impulse and Rotor Modulation (FIRM) uses 64-electrode basket catheters to identify atrial fibrillation (AF)-sustaining sites for ablation, with promising results in many studies. Accordingly, new basket designs are being tested by several groups. We set out to determine the procedural safety of adding basket mapping and map-guided ablation to conventional pulmonary vein isolation (PVI). Methods and results We collected 30 day procedural safety data in five US centres for consecutive patients undergoing FIRM plus PVI (FIRM-PVI) compared with contemporaneous controls undergoing PVI without FIRM. A total of 625 cases were included in this analysis: 325 FIRM-PVI and 300 PVI-controls. FIRM-PVI patients were more likely than PVI-controls to be male (83% vs. 66%, P < 0.001) and have long-standing persistent AF (26% vs. 13%, P < 0.001) reflecting patients referred for FIRM. Total ablation time was greater for FIRM-PVI (62 ± 22 min) vs. PVI-controls (52 ± 18 min, P = 0.03). The complication rate for FIRM-PVI procedures (4.3%) was similar to controls (4.0%, P = 1) for both major and minor complications; no deaths were reported. The rate of complications potentially attributable to the basket catheter was small and did not differ between basket types (Constellation 2.8% vs. FIRMap 1.8%, P = 0.7) or between cases in which basket catheters were and were not used (P = 0.5). Complication rates did not differ between centres (P = 0.6). Conclusions Procedural complications from the use of the basket catheters for AF mapping are low, and thus procedural safety appears similar between FIRM-PVI and PVI-controls in a large multicentre cohort. Future studies are required to determine the optimal approach to maximize the efficacy of FIRM-guided ablation

    Comparative study of acute and mid-term complications with leadless and transvenous cardiac pacemakers

    No full text
    BACKGROUND: Leadless cardiac pacemakers (LCPs) aim to mitigate lead- and pocket-related complications seen with transvenous pacemakers (TVPs). OBJECTIVE: The purpose of this study was to compare complications between the LCP cohort from the LEADLESS Pacemaker IDE Study (Leadless II) trial and a propensity score-matched real-world TVP cohort. METHODS: The multicenter LEADLESS II trial evaluated the safety and efficacy of the Nanostim LCP (Abbott, Abbott Park, IL) using structured follow-up, with serious adverse device effects independently adjudicated. TVP data were obtained from Truven Health MarketScan claims databases for patients implanted with single-chamber TVPs between April 1, 2010 and March 31, 2014 and more than 1 year of preimplant enrollment data. Comorbidities and complications were identified via International Classification of Diseases, Ninth Revision and Current Procedural Terminology codes. Short-term (≤1 months) and mid-term (\u3e1-18 months) complications were compared between the LCP cohort and a propensity score-matched subset of the TVP cohort. RESULTS: Among 718 patients with LCPs (mean age 75.6 ± 11.9 years; 62% men) and 1436 patients with TVPs (mean age 76.1 ± 12.3 years; 63% men), patients with LCPs experienced fewer complications (hazard ratio 0.44; 95% confidence interval 0.32-0.60; P \u3c .001), including short-term (5.8% vs 9.4%; P = .01) and mid-term (0.56% vs 4.9%; P \u3c .001) events. In the short-term time frame, patients with LCPs had more pericardial effusions (1.53% vs 0.35%; P = .005); similar rates of vascular events (1.11% vs 0.42%; P = .085), dislodgments (0.97% vs 1.39%; P = .54), and generator complications (0.70% vs 0.28%; P = .17); and no thoracic trauma compared to patients with TVPs (rate of thoracic trauma 3.27%). In short- and mid-term time frames, TVP events absent from the LCP group included lead-related, pocket-related, and infectious complications. CONCLUSION: Patients with LCPs experienced fewer overall short- and mid-term complications, including infectious and lead- and pocket-related events, but more pericardial effusions, which were uncommon but serious