1,654 research outputs found

    Daily changes in global cloud cover and Earth transits of the heliospheric current sheet

    Get PDF
    Changes in cloud cover are found to occur for periods of a few days following Earth transits of the heliospheric current sheet (HCS), provided also that the transits occur in years of high stratospheric aerosol loading. Using global cloud products from the International Satellite Cloud Climatology Project (ISCCP) D1 data series, epoch superposition analyses were made for various samples of HCS events. For the period August 1991 to June 1994 for the stratospheric aerosol loading due to the Pinatubo eruption, the analysis of the data in 30° geomagnetic latitude intervals revealed that cloud anomalies that were significant and negative were located in the Southern Hemisphere high and middle latitudes, and anomalies that were significant and positive were found in both hemispheres at low latitudes. When the key days in the superposed epoch analysis were determined by minima in the relativistic electron flux, rather than by the HCS crossings, the location of the significant negative anomalies was in the northern high latitudes, and the location of the significant positive anomalies was in middle latitudes in the Northern Hemisphere. The spatial and temporal patterns of these cloud cover variations are in broad agreement with the expected opposite variations at high and low latitudes of the current density Jz in the global electric circuit caused by the relativistic electron flux variations, during periods when the aerosol loading has made a large increase in stratospheric resistivity

    Fluoridated elastomers: in vivo versus in vitro fluoride release

    Get PDF
    OBJECTIVES: To compare (i) the in vivo release of fluoride from fluoridated elastomers to the in vitro release, and (ii) the residual fluoride content of the elastomers after 1 week in the mouth with and without fluoride toothpaste and mouthrinse. DESIGN: A prospective, longitudinal, cross-over study. Subjects and method: Six subjects were recruited by poster to take part in the study. Each subject had one premolar in each quadrant to which a bracket could be fixed and exemplary oral hygiene. Elastomers were then placed on these brackets. Intervention: The study was divided into two parts: (i) subjects used oral hygiene products with fluoride and (ii) oral hygiene products with fluoride were excluded. Both groups of elastomers were left in the mouth for 1 week. After collection the elastomers were stored in distilled water. MAIN OUTCOME MEASURES: The amount of residual fluoride in the ligatures after they have been placed in the mouth for 1 week was compared with the cumulative fluoride release in vitro over 1 week and 6 months. RESULTS: Only 13 per cent of the total amount of fluoride in fluoridated elastomers was released during the first week in vitro, compared with 90 per cent in vivo. There was a significantly greater amount (P = 0.001) of residual fluoride when the elastomers were in the mouth for 1 week in the presence of fluoride toothpaste and mouthrinse, than when fluoride supplements were excluded. CONCLUSIONS: (1) Higher levels of fluoride are lost from the fluoride elastomers in vivo than in vitro during the first week. (2) A significantly greater amount of residual fluoride was released from the elastomers placed in the mouth when fluoride toothpaste and mouthrinse were used

    An evaluation of combined geophysical and geotechnical methods to characterize beach thickness

    Get PDF
    Beaches provide sediment stores and have an important role in the development of the coastline in response to climate change. Quantification of beach thickness and volume is required to assess coastal sediment transport budgets. Therefore, portable, rapid, non-invasive techniques are required to evaluate thickness where environmental sensitivities exclude invasive methods. Site methods and data are described for a toolbox of electrical, electromagnetic, seismic and mechanical based techniques that were evaluated at a coastal site at Easington, Yorkshire. Geophysical and geotechnical properties are shown to be dependent upon moisture content, porosity and lithology of the beach and the morphology of the beach–platform interface. Thickness interpretation, using an inexpensive geographic information system to integrate data, allowed these controls and relationships to be understood. Guidelines for efficient site practices, based upon this case history including procedures and techniques, are presented using a systematic approach. Field results indicated that a mixed sand and gravel beach is highly variable and cannot be represented in models as a homogeneous layer of variable thickness overlying a bedrock half-space

    Orthodontic palatal implants: clinical technique

    Get PDF
    The aim of this paper is to familiarize the readers with some of the clinical considerations necessary to ensure successful use of mid-palatal implants. Both surgical and technical aspects will be discussed along with a description of impression techniques used

    Does the bracket-ligature combination affect the amount of orthodontic space closure over three months? A randomized controlled trial

    No full text
    OBJECTIVE: To investigate the effect of bracket-ligature combination on the amount of orthodontic space closure over three months. DESIGN: Randomized clinical trial with three parallel groups. SETTING: A hospital orthodontic department (Chesterfield Royal Hospital, UK). PARTICIPANTS: Forty-five patients requiring upper first premolar extractions. METHODS: Informed consent was obtained and participants were randomly allocated into one of three groups: (1) conventional pre-adjusted edgewise brackets and elastomeric ligatures; (2) conventional pre-adjusted edgewise brackets and Super Slick((R)) low friction elastomeric ligatures; (3) Damon 3MX((R)) passive self-ligating brackets. Space closure was undertaken on 0.019x0.025-inch stainless steel archwires with nickel-titanium coil springs. Participants were recalled at four weekly intervals. Upper alginate impressions were taken at each visit (maximum three). The primary outcome measure was the mean amount of space closure in a 3-month period. RESULTS: A one-way ANOVA was undertaken [dependent variable: mean space closure (mm); independent variable: group allocation]. The amount of space closure was very similar between the three groups (1 mm per 28 days); however, there was a wide variation in the rate of space closure between individuals. The differences in the amount of space closure over three months between the three groups was very small and non-significant (P = 0.718). CONCLUSION: The hypothesis that reducing friction by modifying the bracket/ligature interface increases the rate of space closure was not supported. The major determinant of orthodontic tooth movement is probably the individual patient response

    Midpalatal implants vs headgear for orthodontic anchorage - a randomized clinical trial: Cephalometric results

    Get PDF
    OBJECTIVE: To compare the clinical effectiveness of the mid-palatal implant as a method of reinforcing anchorage during orthodontic treatment with that of conventional extra-oral anchorage. DESIGN: A prospective, randomized, clinical trial Setting: Chesterfield and North Derbyshire Royal Hospital NHS Trust and the Charles Clifford Dental Hospital, Sheffield. SUBJECTS AND METHODS: 51 orthodontic patients between the ages of 12 and 39, with a class II division 1 malocclusion and ‘absolute anchorage’ requirements were randomly allocated to either receive a mid-palatal implant or headgear to reinforce orthodontic anchorage. The main outcome of the trial was to compare the mesial movement of the molars and incisors of the two treatment groups between T1 (start) and T2 (end of anchorage reinforcement) as measured from cephalometric radiographs. RESULTS: The reproducibility of the measuring technique was acceptable. There were significant differences between the T1 and T2 measurements within the implant group for the position of the maxillary central incisor (p<0.001), position of the maxillary molar (p=0.009) and position of the mandibular molar (p<0.001). There were significant differences within the headgear group for the position of the mandibular central incisor (p<0.045), position of the maxillary molar (p=<0.001) and position of the mandibular molar (p<0.001). All the skeletal and dental points moved mesially more in the headgear group during treatment than in the implant group. These ranged from an average of 0.5mm more mesial for the mandibular permanent molar to 1.5mm more mesial for the maxillary molar and mandibular base. None of the treatment changes between the implant and headgear groups were statistically significant. CONCLUSIONS: Mid-palatal implants are an acceptable technique for reinforcing anchorage in the orthodontic patient

    Midpalatal implants vs headgear for orthodontic anchorage - a randomized clinical trial: Cephalometric results

    Get PDF
    OBJECTIVE: To compare the clinical effectiveness of the mid-palatal implant as a method of reinforcing anchorage during orthodontic treatment with that of conventional extra-oral anchorage. DESIGN: A prospective, randomized, clinical trial Setting: Chesterfield and North Derbyshire Royal Hospital NHS Trust and the Charles Clifford Dental Hospital, Sheffield. SUBJECTS AND METHODS: 51 orthodontic patients between the ages of 12 and 39, with a class II division 1 malocclusion and ‘absolute anchorage’ requirements were randomly allocated to either receive a mid-palatal implant or headgear to reinforce orthodontic anchorage. The main outcome of the trial was to compare the mesial movement of the molars and incisors of the two treatment groups between T1 (start) and T2 (end of anchorage reinforcement) as measured from cephalometric radiographs. RESULTS: The reproducibility of the measuring technique was acceptable. There were significant differences between the T1 and T2 measurements within the implant group for the position of the maxillary central incisor (p<0.001), position of the maxillary molar (p=0.009) and position of the mandibular molar (p<0.001). There were significant differences within the headgear group for the position of the mandibular central incisor (p<0.045), position of the maxillary molar (p=<0.001) and position of the mandibular molar (p<0.001). All the skeletal and dental points moved mesially more in the headgear group during treatment than in the implant group. These ranged from an average of 0.5mm more mesial for the mandibular permanent molar to 1.5mm more mesial for the maxillary molar and mandibular base. None of the treatment changes between the implant and headgear groups were statistically significant. CONCLUSIONS: Mid-palatal implants are an acceptable technique for reinforcing anchorage in the orthodontic patient

    Chemical Abundance Constraints on White Dwarfs as Halo Dark Matter

    Get PDF
    We examine the chemical abundance constraints on a population of white dwarfs in the Halo of our Galaxy. We are motivated by microlensing evidence for massive compact halo objects (Machos) in the Galactic Halo, but our work constrains white dwarfs in the Halo regardless of what the Machos are. We focus on the composition of the material that would be ejected as the white dwarfs are formed; abundance patterns in the ejecta strongly constrain white dwarf production scenarios. Using both analytical and numerical chemical evolution models, we confirm that very strong constraints come from Galactic Pop II and extragalactic carbon abundances. We also point out that depending on the stellar model, significant nitrogen is produced rather than carbon. The combined constraints from C and N give ΩWDh<2×10−4\Omega_{WD} h < 2 \times 10^{-4} from comparison with the low C and N abundances in the Lyα\alpha forest. We note, however, that these results are subject to uncertainties regarding the nucleosynthesis of low-metallicity stars. We thus investigate additional constraints from D and 4^4He, finding that these light elements can be kept within observational limits only for \Omega_{WD} \la 0.003 and for a white dwarf progenitor initial mass function sharply peaked at low mass (2M⊙M_\odot). Finally, we consider a Galactic wind, which is required to remove the ejecta accompanying white dwarf production from the galaxy. We show that such a wind can be driven by Type Ia supernovae arising from the white dwarfs themselves, but these supernovae also lead to unacceptably large abundances of iron. We conclude that abundance constraints exclude white dwarfs as Machos. (abridged)Comment: Written in AASTeX, 26 pages plus 4 ps figure

    Muon decay in a linearly polarized laser field

    Full text link
    In a previous paper, we showed that the decay rate of a muon is only slightly affected by the presence of a circularly polarized laser and we gave an analytic expression for the correction. In this paper, we present the analytical result for the case of a linearly polarized laser. Again the effect of the laser is small.Comment: 6 pages, no figure
    • …
    corecore