312 research outputs found

    Crystallographic order and decomposition of [MnIII6CrIII]3+ single-molecule magnets deposited in submonolayers and monolayers on HOPG studied by means of molecular resolved Atomic Force Microscopy (AFM) and Kelvin Probe Force Microscopy in UHV

    Get PDF
    Gryzia A, Volkmann T, Brechling A, et al. Crystallographic order and decomposition of [MnIII6CrIII]3+ single-molecule magnets deposited in submonolayers and monolayers on HOPG studied by means of molecular resolved Atomic Force Microscopy (AFM) and Kelvin Probe Force Microscopy in UHV. Nanoscale Research Letters. 2014;9(1): 60.Monolayers and submonolayers of [MnIII6CrIII]3+ single-molecule magnets (SMMs) adsorbed on highly oriented pyrolytic graphite (HOPG) using the droplet technique characterized by non-contact atomic force microscopy (nc-AFM) as well as by Kelvin probe force microscopy (KPFM) show island-like structures with heights resembling the height of the molecule. Furthermore, islands were found which revealed ordered 1D as well as 2D structures with periods close to the width of the SMMs. Along this, islands which show half the heights of intact SMMs were observed which are evidences for a decomposing process of the molecules during the preparation. Finally, models for the structure of the ordered SMM adsorbates are proposed to explain the observations

    Lung Cancer Screening with Submillisievert Chest CT: Potential Pitfalls of Pulmonary Findings in Different Readers with Various Experience Levels

    Full text link
    Purpose To assess the interreader variability of submillisievert CT for lung cancer screening in radiologists with various experience levels. Method Six radiologists with different degrees of clinical experience in radiology (range, 1-15 years), rated 100 submillisievert CT chest studies as either negative screening finding (no nodules, benign nodules, nodules 10 mm). Each radiologist interpreted scans randomly ordered and reading time was recorded. Interobserver agreement was assessed with ak statistic. Reasons for differences in nodule classification were analysed on a case-by-case basis. Reading time was correlated with reader experience using Pearson correlation (r). Results The overall interobserver agreement between all readers was moderate (k = 0.454; p < 0.001). In 57 patients, all radiologists agreed on the differentiation of negative and indeterminate/positive finding. In 64 cases disagreement between readers led to different nodule classification. In 8 cases some readers rated the nodule as benign, whereas others scored the case as positive. Overall, disagreement in nodule classification was mostly due to failure in identification of target lesion (n = 40), different lesion measurement (n = 44) or different classification (n = 26). Mean overall reading time per scan was of 2 min 2 s (range: 7s-7 min 45 s) and correlated with reader-experience (r =-0.824). Conclusions Our study showed substantial interobserver variability for the detection and classification of pulmonary nodules in submillisievert CT. This highlights the importance for careful standardisation of screening programs with the objective of harmonizing efforts of involved radiologists across different institutions by defining and assuring quality standards

    Heptanuclear [FeIII6CrIII]3+ Complexes Experimentally Studied by Means of Magnetometry, X-ray Diffraction, XAS, XMCD and Spin-Polarized Electron Spectroscopy in Cross-Comparison with [MnIII6CrIII]3+ Single-Molecule Magnets

    Get PDF
    Dohmeier N, Helmstedt A, Müller N, et al. Heptanuclear [FeIII6CrIII]3+ Complexes Experimentally Studied by Means of Magnetometry, X-ray Diffraction, XAS, XMCD and Spin-Polarized Electron Spectroscopy in Cross-Comparison with [MnIII6CrIII]3+ Single-Molecule Magnets. Magnochemistry. 2016;2(1): 5

    Hemodynamic impact of isobaric levobupivacaine versus hyperbaric bupivacaine for subarachnoid anesthesia in patients aged 65 and older undergoing hip surgery

    Get PDF
    BackgroundThe altered hemodynamics, and therefore the arterial hypotension is the most prevalent adverse effect after subarachnoid anesthesia. The objective of the study was to determine the exact role of local anesthetic selection underlying spinal anesthesia-induced hypotension in the elderly patient. We conducted a descriptive, observational pilot study to assess the hemodynamic impact of subarachnoid anesthesia with isobaric levobupivacaine versus hyperbaric bupivacaine for hip fracture surgery.DescriptionHundred twenty ASA status I-IV patients aged 65 and older undergoing hip fracture surgery were enrolled. The primary objective of our study was to compare hemodynamic effects based on systolic blood pressure (SBP) and dyastolic blood pressure (DBP) values, heart rate (HR) and hemoglobin (Hb) and respiratory effects based on partial oxygen saturation (SpO2%) values. The secondary objective was to assess potential adverse events with the use of levobupivacaine versus bupivacaine. Assessments were performed preoperatively, at 30 minutes into surgery, at the end of anesthesia and at 48 hours and 6 months after surgery.Among intraoperative events, the incidence of hypotension was statistically significantly higher (p <0.05) in group BUPI (38.3%) compared to group LEVO (13.3%). There was a decrease (p <0.05) in systolic blood pressure (SBP) and diastolic blood pressure (DBP) at 30 minutes intraoperatively (19% in group BUPI versus 17% in group LEVO). SpO2% increased at 30 minutes after anesthesia onset (1% in group BUPI versus 1.5% in group LEVO). Heart rate (HR) decreased at 30 minutes after anesthesia onset (5% in group BUPI versus 9% in group L). Hemoglobin (Hb) decreased from time of operating room (OR) admission to the end of anesthesia (9.3% in group BUPI versus 12.5% in group LEVO). The incidence of red blood cell (RBC) transfusion was 13.3% in group BUPI versus 31.7% in group LEVO, this difference was statistically significant. Among postoperative events, the incidence of congestive heart failure (CHF) was significantly higher in group BUPI (8,3%). At 6 months after anesthesia, no differences were found.ConclusionsGiven the hemodynamic stability and lower incidence of intraoperative hypotension observed, levobupivacaine could be the agent of choice for subarachnoid anesthesia in elderly patients

    In-situ estimation of ice crystal properties at the South Pole using LED calibration data from the IceCube Neutrino Observatory

    Get PDF
    The IceCube Neutrino Observatory instruments about 1 km3 of deep, glacial ice at the geographic South Pole using 5160 photomultipliers to detect Cherenkov light emitted by charged relativistic particles. A unexpected light propagation effect observed by the experiment is an anisotropic attenuation, which is aligned with the local flow direction of the ice. Birefringent light propagation has been examined as a possible explanation for this effect. The predictions of a first-principles birefringence model developed for this purpose, in particular curved light trajectories resulting from asymmetric diffusion, provide a qualitatively good match to the main features of the data. This in turn allows us to deduce ice crystal properties. Since the wavelength of the detected light is short compared to the crystal size, these crystal properties do not only include the crystal orientation fabric, but also the average crystal size and shape, as a function of depth. By adding small empirical corrections to this first-principles model, a quantitatively accurate description of the optical properties of the IceCube glacial ice is obtained. In this paper, we present the experimental signature of ice optical anisotropy observed in IceCube LED calibration data, the theory and parametrization of the birefringence effect, the fitting procedures of these parameterizations to experimental data as well as the inferred crystal properties.</p

    Conditional normalizing flows for IceCube event reconstruction

    Get PDF

    Galactic Core-Collapse Supernovae at IceCube: “Fire Drill” Data Challenges and follow-up

    Get PDF
    The next Galactic core-collapse supernova (CCSN) presents a once-in-a-lifetime opportunity to make astrophysical measurements using neutrinos, gravitational waves, and electromagnetic radiation. CCSNe local to the Milky Way are extremely rare, so it is paramount that detectors are prepared to observe the signal when it arrives. The IceCube Neutrino Observatory, a gigaton water Cherenkov detector below the South Pole, is sensitive to the burst of neutrinos released by a Galactic CCSN at a level >10σ. This burst of neutrinos precedes optical emission by hours to days, enabling neutrinos to serve as an early warning for follow-up observation. IceCube\u27s detection capabilities make it a cornerstone of the global network of neutrino detectors monitoring for Galactic CCSNe, the SuperNova Early Warning System (SNEWS 2.0). In this contribution, we describe IceCube\u27s sensitivity to Galactic CCSNe and strategies for operational readiness, including "fire drill" data challenges. We also discuss coordination with SNEWS 2.0

    All-Energy Search for Solar Atmospheric Neutrinos with IceCube

    Get PDF
    The interaction of cosmic rays with the solar atmosphere generates a secondary flux of mesons that decay into photons and neutrinos – the so-called solar atmospheric flux. Although the gamma-ray component of this flux has been observed in Fermi-LAT and HAWC Observatory data, the neutrino component remains undetected. The energy distribution of those neutrinos follows a soft spectrum that extends from the GeV to the multi-TeV range, making large Cherenkov neutrino telescopes a suitable for probing this flux. In this contribution, we will discuss current progress of a search for the solar neutrino flux by the IceCube Neutrino Observatory using all available data since 2011. Compared to the previous analysis which considered only high-energy muon neutrino tracks, we will additionally consider events produced by all flavors of neutrinos down to GeV-scale energies. These new events should improve our analysis sensitivity since the flux falls quickly with energy. Determining the magnitude of the neutrino flux is essential, since it is an irreducible background to indirect solar dark matter searches

    TXS 0506+056 with Updated IceCube Data

    Get PDF
    Past results from the IceCube Collaboration have suggested that the blazar TXS 0506+056 is a potential source of astrophysical neutrinos. However, in the years since there have been numerous updates to event processing and reconstruction, as well as improvements to the statistical methods used to search for astrophysical neutrino sources. These improvements in combination with additional years of data have resulted in the identification of NGC 1068 as a second neutrino source candidate. This talk will re-examine time-dependent neutrino emission from TXS 0506+056 using the most recent northern-sky data sample that was used in the analysis of NGC 1068. The results of using this updated data sample to obtain a significance and flux fit for the 2014 TXS 0506+056 "untriggered" neutrino flare are reported
    corecore