60 research outputs found

    Imaging in percutaneous ablation for atrial fibrillation

    Get PDF
    Percutaneous ablation for electrical disconnection of the arrhythmogenic foci using various forms of energy has become a well-established technique for treating atrial fibrillation (AF). Success rate in preventing recurrence of AF episodes is high although associated with a significant incidence of pulmonary vein (PV) stenosis and other rare complications. Clinical workup of AF patients includes imaging before and after ablative treatment using different noninvasive and invasive techniques such as conventional angiography, transoesophageal and intracardiac echocardiography, computed tomography (CT) and magnetic resonance imaging (MRI), which offer different information with variable diagnostic accuracy. Evaluation before percutaneous ablation involves assessment of PVs (PV pattern, branching pattern, orientation and ostial size) to facilitate position and size of catheters and reduce procedure time as well as examining the left atrium (presence of thrombi, dimensions and volumes). Imaging after the percutaneous ablation is important for assessment of overall success of the procedure and revealing potential complications. Therefore, imaging methods enable depiction of PVs and the anatomy of surrounding structures essential for preprocedural management and early detection of PV stenosis and other ablation-related procedures, as well as long-term follow-up of these patients

    KNIME: the Konstanz Information Miner

    Get PDF
    The Konstanz Information Miner is a modular environment which enables easy visual assembly and interactive execution of a data pipeline. It is designed as a teaching, research and collaboration platform, which enables easy integration of new algorithms, data manipulation or visualization methods as new modules or nodes. In this paper we describe some of the design aspects of the underlying architecture and briefly sketch how new nodes can be incorporated

    MR-IMPACT: comparison of perfusion-cardiac magnetic resonance with single-photon emission computed tomography for the detection of coronary artery disease in a multicentre, multivendor, randomized trial

    Get PDF
    Aims To determine in a multicentre, multivendor trial the diagnostic performance for perfusion-cardiac magnetic resonance (perfusion-CMR) in comparison with coronary X-ray angiography (CXA) and single-photon emission computed tomography (SPECT). Methods and results Of 241 eligible patients from 18 centres, 234 were randomly dosed with 0.01, 0.025, 0.05, 0.075, or 0.1 mmol/kg Gd-DTPA-BMA (Omniscan™, GE-Healthcare) per stress (0.42 mg/kg adenosine) and rest perfusion study. Coronary artery disease (CAD) was defined as diameter stenosis ≥50% on quantitative CXA. Five CMR and eight SPECT studies (of 225 complete studies) were excluded from analyses due to inadequate quality (three blinded readers scored per modality). The comparison of CMR vs. SPECT was based on receiver operating characteristic (ROC) analysis. Perfusion-CMR at the optimal CM dose (0.1 mmol/kg) had similar performance as SPECT, if only the SPECT studies of the 42 patients with this dose were considered [area under ROC curve (AUC): 0.86 ± 0.06 vs. 0.75 ± 0.09 for SPECT, P = 0.12]; however, diagnostic performance of perfusion-CMR was better vs. the entire SPECT population (AUC: 0.67 ± 0.05, n = 212, P = 0.013). Conclusions In this multicentre, multivendor trial, ROC analyses suggest perfusion-CMR as a valuable alternative to SPECT for CAD detection showing equal performance in the head-to-head comparison. Comparing perfusion-CMR with the entire SPECT population suggests CMR superiority over SPECT, which warrants further evaluation in larger trial

    MR-IMPACT II: Magnetic Resonance Imaging for Myocardial Perfusion Assessment in Coronary artery disease Trial: perfusion-cardiac magnetic resonance vs. single-photon emission computed tomography for the detection of coronary artery disease: a comparative multicentre, multivendor trial

    Get PDF
    Aims Perfusion-cardiac magnetic resonance (CMR) has emerged as a potential alternative to single-photon emission computed tomography (SPECT) to assess myocardial ischaemia non-invasively. The goal was to compare the diagnostic performance of perfusion-CMR and SPECT for the detection of coronary artery disease (CAD) using conventional X-ray coronary angiography (CXA) as the reference standard. Methods and results In this multivendor trial, 533 patients, eligible for CXA or SPECT, were enrolled in 33 centres (USA and Europe) with 515 patients receiving MR contrast medium. Single-photon emission computed tomography and CXA were performed within 4 weeks before or after CMR in all patients. The prevalence of CAD in the sample was 49%. Drop-out rates for CMR and SPECT were 5.6 and 3.7%, respectively (P = 0.21). The primary endpoint was non-inferiority of CMR vs. SPECT for both sensitivity and specificity for the detection of CAD. Readers were blinded vs. clinical data, CXA, and imaging results. As a secondary endpoint, the safety profile of the CMR examination was evaluated. For CMR and SPECT, the sensitivity scores were 0.67 and 0.59, respectively, with the lower confidence level for the difference of +0.02, indicating superiority of CMR over SPECT. The specificity scores for CMR and SPECT were 0.61 and 0.72, respectively (lower confidence level for the difference: −0.17), indicating inferiority of CMR vs. SPECT. No severe adverse events occurred in the 515 patients. Conclusion In this large multicentre, multivendor study, the sensitivity of perfusion-CMR to detect CAD was superior to SPECT, while its specificity was inferior to SPECT. Cardiac magnetic resonance is a safe alternative to SPECT to detect perfusion deficits in CA

    Guideline adherence in the use of coronary angiography in patients presenting at the emergency department without myocardial infarction – results from the German ENLIGHT-KHK project

    Get PDF
    Background For patients with acute myocardial infarction (AMI), direct coronary angiography (CA) is recommended, while for non-AMI patients, the diagnostic work-up depends on clinical criteria. This analysis provides initial prospective German data for the degree of guideline-adherence (GL) in the use of CA on non-AMI patients presenting at the emergency department (ED) with suspected acute coronary syndrome (ACS) according to the 2015 ESC-ACS-GL. Furthermore the implications of the application of the 2020 ESC-ACS-GL recommendations were evaluated. Methods Patient symptoms were identified using a standardized questionnaire; medical history and diagnostic work-up were acquired from health records. In accordance with the 2015 ESC-ACS-GL, CA was considered GL-adherent if intermediate risk criteria (IRC) were present or non-invasive, image-guided testing (NIGT) was pathological. Results Between January 2019 and August 2021, 229 patients were recruited across seven centers. Patients presented with chest pain, dyspnea, and other symptoms in 66.7%, 16.2% and 17.1%, respectively, were in mean 66.3 ± 10.5 years old, and 36.3% were female. In accordance with the 2015 ESC-ACS-GL, the use of CA was GL-adherent for 64.0% of the patients. GL-adherent compared to non-adherent use of CA resulted in revascularization more often (44.5% vs. 17.1%, p < 0.001). Applying the 2020 ESC-ACS-GL, 20.4% of CA would remain GL-adherent. Conclusions In the majority of cases, the use of CA was adherent to the 2015 ESC-ACS-GL. With regard to the 2020 and 2023 ESC-ACS-GL, efforts to expand the utilization of NIGT are crucial, especially as GL-adherent use of CA is more likely to result in revascularization

    Left Ventricular Hypertrabeculation Is Not Associated With Cardiovascular Morbity or Mortality: Insights From the Eurocmr Registry

    Get PDF
    Aim: Left ventricular non-compaction (LVNC) is perceived as a rare high-risk cardiomyopathy characterized by excess left ventricular (LV) trabeculation. However, there is increasing evidence contesting the clinical significance of LV hyper-trabeculation and the existence of LVNC as a distinct cardiomyopathy. The aim of this study is to assess the association of LV trabeculation extent with cardiovascular morbidity and all-cause mortality in patients undergoing clinical cardiac magnetic resonance (CMR) scans across 57 European centers from the EuroCMR registry. Methods and Results: We studied 822 randomly selected cases from the EuroCMR registry. Image acquisition was according to international guidelines. We manually segmented images for LV chamber quantification and measurement of LV trabeculation (as per Petersen criteria). We report the association between LV trabeculation extent and important cardiovascular morbidities (stroke, atrial fibrillation, heart failure) and all-cause mortality prospectively recorded over 404 ± 82 days of follow-up. Maximal non-compaction to compaction ratio (NC/C) was mean (standard deviation) 1.81 ± 0.67, from these, 17% were above the threshold for hyper-trabeculation (NC/C &gt; 2.3). LV trabeculation extent was not associated with increased risk of the defined outcomes (morbidities, mortality, LV CMR indices) in the whole cohort, or in sub-analyses of individuals without ischaemic heart disease, or those with NC/C &gt; 2.3. Conclusion: Among 882 patients undergoing clinical CMR, excess LV trabeculation was not associated with a range of important cardiovascular morbidities or all-cause mortality over ~12 months of prospective follow-up. These findings suggest that LV hyper-trabeculation alone is not an indicator for worse cardiovascular prognosis

    Current variables, definitions and endpoints of the European Cardiovascular Magnetic Resonance Registry

    Get PDF
    BACKGROUND: Cardiovascular magnetic resonance (CMR) is increasingly used in daily clinical practice. However, little is known about its clinical utility such as image quality, safety and impact on patient management. In addition, there is limited information about the potential of CMR to acquire prognostic information. METHODS: The European Cardiovascular Magnetic Resonance Registry (EuroCMR Registry) will consist of two parts: 1) Multicenter registry with consecutive enrolment of patients scanned in all participating European CMR centres using web based online case record forms. 2) Prospective clinical follow up of patients with suspected coronary artery disease (CAD) and hypertrophic cardiomyopathy (HCM) every 12 months after enrolment to assess prognostic data. CONCLUSION: The EuroCMR Registry offers an opportunity to provide information about the clinical utility of routine CMR in a large number of cases and a diverse population. Furthermore it has the potential to gather information about the prognostic value of CMR in specific patient populations
    corecore