25 research outputs found

    Low‐voltage shock impedance measurements: A false sense of security

    Get PDF
    Background: Implantable cardioverter defibrillators use low-voltage shock impedance measurements to monitor the lead integrity. However, previous case reports suggest that low-voltage shock impedance measurements may fail to detect insulation breaches that can cause life-threatening electrical short circuits. Methods and results: We report six cases of insulation breaches in transvenous defibrillation leads that were not obvious during standard interrogations and testing of the lead beforehand. In two cases, an electrical short circuit during commanded shock delivery for internal electrical cardioversion resulted in a total damage of the ICD generator. In one of these cases, commanded shock delivery induced ventricular fibrillation, which required external defibrillation. In two cases, a shock due to ventricular tachycardia was aborted as the shock impedance was less than 20 Ω. However, in both cases the tiny residual shock energy terminated the ventricular tachycardia. In contrast, in one case the residual energy of the aborted shock did not end ventricular fibrillation induced at defibrillator threshold testing. In one case, the ICD indicated an error code for a short circuit condition detected during an adequate shock delivery. Conclusions: This case series illustrates that low-voltage shock impedance measurements can fail to detect insulation breaches. These data suggest that in patients without a contraindication, traditional defibrillator threshold testing or high voltage synchronized shock at the time of device replacement should be considered

    A worldwide survey on incidence, management, and prognosis of oesophageal fistula formation following atrial fibrillation catheter ablation: the POTTER-AF study

    Get PDF
    AIMS Oesophageal fistula represents a rare but dreadful complication of atrial fibrillation catheter ablation. Data on its incidence, management, and outcome are sparse. METHODS AND RESULTS This international multicentre registry investigates the characteristics of oesophageal fistulae after treatment of atrial fibrillation by catheter ablation. A total of 553 729 catheter ablation procedures (radiofrequency: 62.9%, cryoballoon: 36.2%, other modalities: 0.9%) were performed, at 214 centres in 35 countries. In 78 centres 138 patients [0.025%, radiofrequency: 0.038%, cryoballoon: 0.0015% (P < 0.0001)] were diagnosed with an oesophageal fistula. Peri-procedural data were available for 118 patients (85.5%). Following catheter ablation, the median time to symptoms and the median time to diagnosis were 18 (7.75, 25; range: 0-60) days and 21 (15, 29.5; range: 2-63) days, respectively. The median time from symptom onset to oesophageal fistula diagnosis was 3 (1, 9; range: 0-42) days. The most common initial symptom was fever (59.3%). The diagnosis was established by chest computed tomography in 80.2% of patients. Oesophageal surgery was performed in 47.4% and direct endoscopic treatment in 19.8% and conservative treatment in 32.8% of patients. The overall mortality was 65.8%. Mortality following surgical (51.9%) or endoscopic treatment (56.5%) was significantly lower as compared to conservative management (89.5%) [odds ratio 7.463 (2.414, 23.072) P < 0.001]. CONCLUSION Oesophageal fistula after catheter ablation of atrial fibrillation is rare and occurs mostly with the use of radiofrequency energy rather than cryoenergy. Mortality without surgical or endoscopic intervention is exceedingly high

    Heart failure after pressure overload in autosomal-dominant desminopathies: Lessons from heterozygous DES-p.R349P knock-in mice

    Get PDF
    Background Mutations in the human desmin gene (DES) cause autosomal-dominant and -recessive cardiomyopathies, leading to heart failure, arrhythmias, and AV blocks. We analyzed the effects of vascular pressure overload in a patient-mimicking p.R349P desmin knock-in mouse model that harbors the orthologue of the frequent human DES missense mutation p. R350P. Methods and results Transverse aortic constriction (TAC) was performed on heterozygous (HET) DES-p.R349P mice and wild-type (WT) littermates. Echocardiography demonstrated reduced left ventricular ejection fraction in HET-TAC (WT-sham: 69.5 ± 2.9%, HET-sham: 64.5 ± 4.7%, WTTAC: 63.5 ± 4.9%, HET-TAC: 55.7 ± 5.4%; p<0.01). Cardiac output was significantly reduced in HET-TAC (WT sham: 13088 ± 2385 μl/min, HET sham: 10391 ± 1349μl/min, WT-TAC: 8097 ± 1903μl/min, HET-TAC: 5793 ± 2517μl/min; p<0.01). Incidence and duration of AV blocks as well as the probability to induce ventricular tachycardias was highest in HET-TAC. We observed reduced mtDNA copy numbers in HET-TAC (WT-sham: 12546 ± 406, HET-sham: 13526 ± 781, WT-TAC: 11155 ± 3315, HET-TAC: 8649 ± 1582; p = 0.025), but no mtDNA deletions. The activity of respiratory chain complexes I and IV showed the greatest reductions in HET-TAC. Conclusion Pressure overload in HET mice aggravated the clinical phenotype of cardiomyopathy and resulted in mitochondrial dysfunction. Preventive avoidance of pressure overload/arterial hypertension in desminopathy patients might represent a crucial therapeutic measure

    A worldwide survey on incidence, management and prognosis of oesophageal fistula formation following atrial fibrillation catheter ablation: The POTTER-AF study.

    Get PDF
    AIMS Oesophageal fistula represents a rare but dreadful complication of atrial fibrillation catheter ablation. Data on its incidence, management and outcome are sparse. METHODS AND RESULTS This international multicenter registry investigates the characteristics of oesophageal fistulae after treatment of atrial fibrillation by catheter ablation. A total of 553,729 catheter ablation procedures (radiofrequency: 62.9%, cryoballoon: 36.2%, other modalities: 0.9%) were performed at 214 centers in 35 countries. In 78 centers 138 patients (0.025%, radiofrequency: 0.038%, cryoballoon: 0.0015% (p<0.0001)) were diagnosed with an oesophageal fistula. Periprocedural data were available for 118 patients (85.5%). Following catheter ablation, the median time to symptoms and the median time to diagnosis were 18 (7.75, 25; range: 0-60) days and 21 (15, 29.5; range: 2-63) days, respectively. The median time from symptom onset to oesophageal fistula diagnosis was 3 (1, 9; range: 0-42) days. The most common initial symptom was fever (59.3%). The diagnosis was established by chest computed tomography in 80.2% of patients. Oesophageal surgery was performed in 47.4% and direct endoscopic treatment in 19.8%, and conservative treatment in 32.8% of patients. The overall mortality was 65.8%. Mortality following surgical (51.9%) or endoscopic treatment (56.5%) was significantly lower as compared to conservative management (89.5%) (odds ratio 7.463 (2.414, 23.072) p<0.001). CONCLUSIONS Oesophageal fistula after catheter ablation of atrial fibrillation is rare and occurs mostly with the use of radiofrequency energy rather than cryoenergy. Mortality without surgical or endoscopic intervention is exceedingly high

    Cannabinoid receptor 1 signalling modulates stress susceptibility and microglial responses to chronic social defeat stress

    No full text
    Psychosocial stress is one of the main environmental factors contributing to the development of psychiatric disorders. In humans and rodents, chronic stress is associated with elevated inflammatory responses, indicated by increased numbers of circulating myeloid cells and activation of microglia, the brain-resident immune cells. The endocannabinoid system (ECS) regulates neuronal and endocrine stress responses via the cannabinoid receptor 1 (CB1). CB1-deficient mice (Cnr