236 research outputs found

    Optimal Selection of Rotor Bar Number in Multiphase Cage Induction Motors

    Get PDF
    Rules for the selection of rotor bar numbers which minimize current and torque ripples are derived in this paper for a general symmetrical multiphase cage induction machine with prime phase number and integral slot winding. Analytically obtained expressions for optimal rotor bar number selection are validated by means of totally independent simulations, one based on a parameterized winding function (PWF) model of the induction machine and the other employing time-stepping finite element analysis (TSFEA). As a case study, five-phase four-pole cage induction motors with forty stator slots and different number of rotor bars are comparatively analyzed. Results obtained from the PWF model are in excellent accordance with those independently obtained by TSFEA and both confirm the correctness of the proposed selection criteria. The practical motivation of the study is that an incorrect selection of rotor bar number can lead to parasitic torques of significant amplitude and, presently, there are no general rules available in the literature which may guide designers towards an optimal design choice for a general number of phases

    An Algebraic Algorithm for Motor Voltage Waveform Prediction in Dual-LCI Drives With Interconnected DC-Links

    Get PDF
    Load-commutated inverters (LCI's) are often used to supply dual-three-phase synchronous motors in high-power variable-speed applications. A pair of LCIs is used in this arrangement to feed the two motor three-phase winding sets. In order to cope with inter-harmonic issues, a drive configuration with an interconnection of the two LCI dc-links has been proposed. In this paper, such a drive design is shown to produce an increased voltage stress on motor windings compared with traditional configurations. The problem is investigated in the paper by proposing an algebraic algorithm capable of predicting the steady-state voltage waveform applied to the motor terminals and arising between the star points of the two winding sets. Unlike conventional dynamic simulations, the proposed approach gives practically instantaneous results, making it possible to quickly investigate a wide number of possible operating conditions. Furthermore, it requires a limited knowledge of system parameters, which are often hardly available. Its reliability and accuracy are assessed by comparison with measurements on a test drive system and examples are given of the method application to the sizing of motor insulation system

    HRV in active-duty special forces and public order military personnel

    Get PDF
    Heart rate variability (HRV) is a simple, non-invasive, real-time analyzable, and highly reproducible measurement that captures incidences for assessing a person’s health and physical condition. Public security jobs are characterized by major exposure to risk factors known to influence the cardiovascular response to stimuli, e.g., night shifts, highly physically demanding activity, and acute stress activity. This study aimed to evaluate the HRV parameters in a population of 112 male personnel of the special forces and public order of the Carabinieri, aged 25-59, when engaged in several duty tasks, such as paratroopers, night shift police station officers, night shift patrol, dynamic precision shooting evaluative team, dynamic precision shooting non-evaluative team, and office clerks (used as control group). During the specific task of each participant, the HRV parameters were collected with wearable devices and processed. The HRV parameters in the time and frequency domains collected were average heart rate, standard deviation of all normal RR intervals, root mean square of successive differences in adjacent normal-to-normal (NN) intervals, very-low-frequency power, low-frequency power, high-frequency power, stress index, parasympathetic nervous system activity index, and sympathetic nervous system activity index. Parametric tests for independent series to compare the HRV parameters by subgroups within the study subjects were used. A multivariate linear regression analysis was conducted to evaluate the association between the HRV parameters and some personal and organizational factors. The comparison between different subgroups showed that activities with a high demand for concentration and precision, as is the case with paratroopers and dynamic precision shooters, differ significantly from activities that can be defined as routine, such as office work. Other activities, such as patrolling or remote management from operations centers, although including critical elements, did not deviate significantly from the control group. The study of HRV parameters is therefore a useful tool for occupational physicians, both for addressing work suitability assessments and for better targeting health promotion campaigns, to be considered as being aimed at monitoring the subject’s physiological parameters, and not at the diagnosis of any pathological condition, which should always be carried out by the medical specialist

    Dental implants with anti-biofilm properties: A pilot study for developing a new sericin-based coating

    Get PDF
    Aim: several strategies have been tested in recent years to prevent bacterial colonization of dental implants. Sericin, one of the two main silk proteins, possesses relevant biological activities and also literature reports about its potential antibacterial properties, but results are discordant and not yet definitive. The aim of this study was to evaluate the effectiveness of different experimental protocols in order to obtain a sericin-based coating on medical grade titanium (Ti) able to reduce microbial adhesion to the dental implant surface. Materials and Methods: different strategies for covalent bonding of sericin to Ti were pursued throughout a multi-step procedure on Ti-6Al-4V disks. The surface of grade 5 Ti was initially immersed in NaOH solution to obtain the exposure of functional -OH groups. Two different silanization strategies were then tested using aminopropyltriethoxysilane (APTES). Eventually, the bonding between silanized Ti-6Al-4V and sericin was obtained with two different crosslinking processes: glutaraldehyde (GLU) or carbodiimide/N-Hydroxy-succinimide (EDC/NHS). Micro-morphological and compositional analyses were performed on the samples at each intermediate step to assess the most effective coating strategy able to optimize the silanization and bioconjugation processes. Microbiological tests on the coated Ti-6Al-4V disks were conducted in vitro using a standard biofilm producer strain of Staphylococcus aureus (ATCC 6538) to quantify the inhibition of microbial biofilm formation (anti-biofilm efficacy) at 24 hours. Results: both silanization techniques resulted in a significant increase of silicon (Si) on the Ti-6Al-4V surfaces etched with NaOH. Differences were found between GLU and EDC/NHS bioconjugation strategies in terms of composition, surface micro-morphology and anti-biofilm efficacy. Ti-6Al-4V samples coated with GLU-bound sericin after silanization obtained via vapor phase deposition proved that this technique is the most convenient and effective coating strategy, resulting in a bacterial inhibition of about 53% in respect to the uncoated Ti-6Al-4V disks. Conclusions: The coating with glutaraldehyde-bound sericin after silanization in the vapor phase showed promising bacterial inhibition values with a significant reduction of S. aureus biofilm. Further studies including higher number of replicates and more peri-implant-relevant microorganisms are needed to evaluate the applicability of this experimental protocol to dental implants. View Full-Tex

    Hybrid Metal-Dielectric Plasmonic Zero Mode Waveguide for Enhanced Single Molecule Detection

    Full text link
    We fabricated hybrid metal-dielectric nanoantennas and measured their optical response at three different wavelengths. The nanostructure is fabricated on a bilayer film formed by the sequential deposition of silicon and gold on a transparent substrate. The optical characterization is done via fluorescence measurements. We characterized the fluorescence enhancement, as well as the lifetime and detection volume reduction for each wavelength. We observe that the hybrid metal-dielectric nanoantennas behave as enhanced Zero Mode Waveguides in the near-infrared spectral region. Their detection volume is such that they can perform enhanced single-molecule detection at tens of microM. However, a wavelength blue-shift of 40 nm dramatically decreases the performance of the nanoantennas. We compared their behavior with that of a golden ZMW, and we verified that the dielectric silicon layer improves the design. We interpreted the experimental observations with the help of numerical simulations. In addition, the simulations showed that the field enhancement of the structure highly depends on the incoming beam: tightly focused beams yield lower field enhancements than plane-waves

    Optimal Selection of Rotor Bar Number for Minimizing Torque and Current Pulsations due to Rotor Slot Harmonics in Three-Phase Cage Induction Motors

    Get PDF
    The paper develops a method to choose the number of rotor bars in order to eliminate rotor slot harmonics in stator current spectrum and pulsation torques that are their consequence. Mains-fed, three-phase cage induction motors with the most common number of pole pairs and number of stator slots, that result in integer slot winding, are analyzed. The analysis is based on the recently derived general rule for optimal selection of rotor bars, valid for symmetrical multiphase machine with prime number of phases and integer slot stator winding. As a tool for validation of analytically predicted results, parameterized winding function (PWF) model is used. Electromagnetic torque ripple factor is used as a measure of goodness of the number of rotor bar selection. The practical motivation of the study is an attempt to supersede the many existing rules for rotor bar number selection that, depending on the source, may be different, and provide a unified general approach to the problem. One of the main findings derived in the paper is ascertainment that increasing the number of pole pairs increases the degree of freedom in choosing the proper number of rotor bars. The same applies when the number of motor phases increases

    Medical-grade silicone coated with rhamnolipid R89 is effective against Staphylococcus spp. Biofilms

    Get PDF
    Staphylococcus aureus and Staphylococcus epidermidis are considered two of the most important pathogens, and their biofilms frequently cause device-associated infections. Microbial biosurfactants recently emerged as a new generation of anti-adhesive and anti-biofilm agents for coating implantable devices to preserve biocompatibility. In this study, R89 biosurfactant (R89BS) was evaluated as an anti-biofilm coating on medical-grade silicone. R89BS is composed of homologues of the mono- (75%) and di-rhamnolipid (25%) families, as evidenced by mass spectrometry analysis. The antimicrobial activity against Staphylococcus spp. planktonic and sessile cells was evaluated by microdilution and metabolic activity assays. R89BS inhibited S. aureus and S. epidermidis growth with minimal inhibitory concentrations (MIC99) of 0.06 and 0.12 mg/mL, respectively and dispersed their pre-formed biofilms up to 93%. Silicone elastomeric discs (SEDs) coated by R89BS simple adsorption significantly counteracted Staphylococcus spp. biofilm formation, in terms of both built-up biomass (up to 60% inhibition at 72 h) and cell metabolic activity (up to 68% inhibition at 72 h). SEM analysis revealed significant inhibition of the amount of biofilm-covered surface. No cytotoxic effect on eukaryotic cells was detected at concentrations up to 0.2 mg/mL. R89BS-coated SEDs satisfy biocompatibility requirements for leaching products. Results indicate that rhamnolipid coatings are effective anti-biofilm treatments and represent a promising strategy for the prevention of infection associated with implantable devices

    Assessing the efficacy and cost of detergents used in a primary care automated washer disinfector

    Get PDF
    Background: Cleaning of re-usable medical devices is a critical control point in the decontamination cycle, although defined end-points of the process are controversial. Objective: Investigate cleaning efficacy and cost of different detergent classes in an automated washer disinfector (AWD) designed for dental practice. Methods: Loads comprised test soiled dental hand instruments in cassettes and extraction forceps. Residual protein assayed using the International standard method (ISO 15883-5:2005) 1% SDS elution with ortho-phthalaldehyde (OPA) or GBox technology (on instrument OPA analysis). Short (60 minutes) and long (97 minutes) AWD cycles were used with four different classes of detergents, tap water and reverse osmosis water. Results: SDS elution analysis (N = 612 instruments) demonstrated four detergents with both wash cycles achieved equivalent cleanliness levels and below a threshold of 200 μg protein/instrument. GBox methodology (N = 575) using UK Department of Health threshold of 5 μg/instrument side demonstrated that tap water performed with the greatest efficacy for all types of instruments and cycle types. Conclusions: Using International standard methodology, different detergent classes had equivalence in cleaning efficacy. Cheaper detergents used in this study performed with similar efficacy to more expensive solutions. Findings emphasise the importance of validating the detergent (type and concentration) for each AWD

    Fast and real-time electrical transistor assay for quantifying SARS-CoV-2 neutralizing antibodies

    Get PDF
    Due to the SARS-CoV-2 pandemic renewed attention has been directed towards viral neutralization assays and neutralizing antibodies quantification, for vaccine pre-clinical trials and determining vaccine efficacy over time. The gold standard to assess antibody titer is the plaque reduction neutralization test, an end-point assay which evaluates the highest serum antibody dilution that neutralizes viral replication, by inspecting the cytopathic effect induced on cell cultures. Here, we use planar, PEDOT:PSS-based organic electrochemical transistors for real-time, remote-controlled, reliable and fast electrical monitoring of the cytopathic effect induced by SARS29 CoV-2 on Vero E6 cell lines, allowing the quantification of serum neutralizing titer. Our low-cost and scalable device has the potential to speed-up large-scale viral neutralization screening without the need for cancerous staining or highly specialized operators. Finally, the technology could be easily transferred to assess neutralizing antibody response towards different viruses in their permissive cell substrates

    Effects of mushroom and chicory extracts on the shape, physiology and proteome of the cariogenic bacterium Streptococcus mutans

    Get PDF
    open16siDental caries is an infectious disease which results from the acidic demineralisation of the tooth enamel and dentine as a consequence of the dental plaque (a microbial biofilm) accumulation. Research showed that several foods contain some components with antibacterial and antiplaque activity. Previous studies indicated antimicrobial and antiplaque activities in a low-molecular-mass (LMM) fraction of extracts from either an edible mushroom (Lentinus edodes) or from Italian red chicory (Cichorium intybus).Signoretto, Caterina; Marchi, Anna; Bertoncelli, Anna; Burlacchini, Gloria; Milli, Alberto; Tessarolo, Francesco; Caola, Iole; Papetti, Adele; Pruzzo, Carla; Zaura, Egija; Lingström, Peter; Ofek, Itzhak; Spratt, David A; Pratten, Jonathan; Wilson, Michael; Canepari, PietroSignoretto, Caterina; Marchi, Anna; Bertoncelli, Anna; Burlacchini, Gloria; Milli, Alberto; Tessarolo, Francesco; Caola, Iole; Papetti, Adele; Pruzzo, Carla; Zaura, Egija; Lingström, Peter; Ofek, Itzhak; Spratt, David A; Pratten, Jonathan; Wilson, Michael; Canepari, Pietr
    • …
    corecore