602 research outputs found

    SYSTEM AND METHODS FOR VENTILATION THROUGH A BODY CAVITY

    Get PDF
    A system and methods for the delivery of oxygen through a body cavity of a subject using oxygen microbubbles . Through circulation of oxygen microbubbles through the body cavity , oxygen and carbon dioxide exchange may occur . Overall improvement in extending survival rate time during emergency situations caused by pulmonary or similar oxygen - intake restricting injury and / or failure may be achieved through use of the invented system and methods

    A Method for Measuring the Attachment Strength of the Cestode \u3ci\u3eHymenolepis diminuta\u3c/i\u3e to the Rat Intestine

    Get PDF
    A unique adaptation of many internal parasites of mammals is their ability to stay in the intestine for extended periods of time and resist the normal peristaltic movements and forces that push and expel material. To better understand parasite adhesion behavior and replicate their attachment method in medical devices, an experiment was designed and performed using the rat tapeworm, Hymenolepis diminuta. The experiment employed a tensile test machine and a digital scale and was designed to calculate the attachment strength of the scolex to the mucosa through the change of the value of the digital scale during the tensile test. The attachment force of H. diminuta is 0.021 ± 0.011 g. This method could be applied in studies of parasite biomechanics and the results may help medical device researchers to better mimic the unique functional morphology of this species of parasite

    Evaluation of Peritoneal Microbubble Oxygenation Therapy in a Rabbit Model of Hypoxemia

    Get PDF
    Alternative extrapulmonary oxygenation technologies are needed to treat patients suffering from severe hypoxemia refractory to mechanical ventilation. We previously demonstrated that peritoneal microbubble oxygenation (PMO), in which phospholipid-coated oxygen microbubbles (OMBs) are delivered into the peritoneal cavity, can successfully oxygenate rats suffering from a right pneumothorax. This study addressed the need to scale up the procedure to a larger animal with a splanchnic cardiac output similar to humans. Our results show that PMO therapy can double the survival time of rabbits experiencing complete tracheal occlusion from6.6 ± 0.6 min for the saline controls to 12.2 ± 3.0 min for the bolus PMO-treated cohort. Additionally, we designed and tested a new peritoneal delivery system to circulate OMBs through the peritoneal cavity. Circulation achieved a similar survival benefit to bolus delivery under these conditions. Overall, these results support the feasibility of the PMO technology to provide extrapulmonary ventilation for rescue of severely hypoxic patients

    Wide-temperature integrated operational amplifier

    Get PDF
    The present invention relates to a reference current circuit. The reference circuit comprises a low-level current bias circuit, a voltage proportional-to-absolute temperature generator for creating a proportional-to-absolute temperature voltage (VPTAT), and a MOSFET-based constant-IC regulator circuit. The MOSFET-based constant-IC regulator circuit includes a constant-IC input and constant-IC output. The constant-IC input is electrically connected with the VPTAT generator such that the voltage proportional-to-absolute temperature is the input into the constant-IC regulator circuit. Thus the constant-IC output maintains the constant-IC ratio across any temperature range

    A survey of small bowel modelling and its applications for capsule endoscopy

    Get PDF
    This is the final version. Available on open access from Elsevier via the DOI in this recordThe small intestine, an anatomical site previously considered inaccessible to clinicians due to its small diameter and length, is the part of the gastrointestinal tract between the stomach and the colon. Since its introduction into clinical practice two decades ago, capsule endoscopy has become established as the primary modality for examining the surface lining of the small intestine. Today, researchers continue to develop ground-breaking technologies for novel miniature devices aiming for tissue biopsy, drug delivery and therapy. The purpose of this paper is to provide researchers and engineers in this area a comprehensive review of the progress in understanding the anatomy and physiology of the small intestine and how this understanding was translated to virtual and physical test platforms for assessing the performance of these intestinal devices. This review will cover both theoretical and practical studies on intestinal motor activities and the work on mathematical modelling and experimental investigation of capsule endoscope in the small intestine. In the end, the requirements for improving the current work are drawn, and the expectations on future research in this field are provided.Engineering and Physical Sciences Research Council (EPSRC)China Scholarship Counci

    Artificial intelligence in fracture detection: a systematic review and meta-analysis

    Get PDF
    Background: Patients with fractures are a common emergency presentation and may be misdiagnosed at radiologic imaging. An increasing number of studies apply artificial intelligence (AI) techniques to fracture detection as an adjunct to clinician diagnosis. Purpose: To perform a systematic review and meta-analysis comparing the diagnostic performance in fracture detection between AI and clinicians in peer-reviewed publications and the gray literature (ie, articles published on preprint repositories). Materials and Methods: A search of multiple electronic databases between January 2018 and July 2020 (updated June 2021) was performed that included any primary research studies that developed and/or validated AI for the purposes of fracture detection at any imaging modality and excluded studies that evaluated image segmentation algorithms. Meta-analysis with a hierarchical model to calculate pooled sensitivity and specificity was used. Risk of bias was assessed by using a modified Prediction Model Study Risk of Bias Assessment Tool, or PROBAST, checklist. Results: Included for analysis were 42 studies, with 115 contingency tables extracted from 32 studies (55061 images). Thirty-seven studies identified fractures on radiographs and five studies identified fractures on CT images. For internal validation test sets, the pooled sensitivity was 92% (95% CI: 88, 93) for AI and 91% (95% CI: 85, 95) for clinicians, and the pooled specificity was 91% (95% CI: 88, 93) for AI and 92% (95% CI: 89, 92) for clinicians. For external validation test sets, the pooled sensitivity was 91% (95% CI: 84, 95) for AI and 94% (95% CI: 90, 96) for clinicians, and the pooled specificity was 91% (95% CI: 81, 95) for AI and 94% (95% CI: 91, 95) for clinicians. There were no statistically significant differences between clinician and AI performance. There were 22 of 42 (52%) studies that were judged to have high risk of bias. Meta-regression identified multiple sources of heterogeneity in the data, including risk of bias and fracture type. Conclusion: Artificial intelligence (AI) and clinicians had comparable reported diagnostic performance in fracture detection, suggesting that AI technology holds promise as a diagnostic adjunct in future clinical practice

    Testing oxygenated microbubbles via intraperitoneal and intrathoracic routes on a large pig model of LPS-induced acute respiratory distress syndrome

    Get PDF
    With a mortality rate of 46% before the onset of COVID-19, acute respiratory distress syndrome (ARDS) affected 200,000 people in the US, causing 75,000 deaths. Mortality rates in COVID-19 ARDS patients are currently at 39%. Extrapulmonary support for ARDS aims to supplement mechanical ventilation by providing life-sustaining oxygen to the patient. A new rapid-onset, human-sized pig ARDS model in a porcine intensive care unit (ICU) was developed. The pigs were nebulized intratracheally with a high dose (4 mg/kg) of the endotoxin lipopolysaccharide (LPS) over a 2 h duration to induce rapid-onset moderate-to- severe ARDS. They were then catheterized to monitor vitals and to evaluate the therapeutic effect of oxygenated microbubble (OMB) therapy delivered by intrathoracic (IT) or intraperitoneal (IP) administration. Post-LPS administration, the PaO2 value dropped below 70 mmHg, the PaO2/FiO2 ratio dropped below 200 mmHg, and the heart rate increased, indicating rapidly developing (within 4 h) moderate-to- severe ARDS with tachycardia. The SpO2 and PaO2 of these LPS-injured pigs did not show significant improvement after OMB administration, as they did in our previous studies of the therapy on small animal models of ARDS injury. Furthermore, pigs receiving OMB or saline infusions had slightly lower survival than their ARDS counterparts. The OMB administration did not induce a statistically significant or clinically relevant therapeutic effect in this model; instead, both saline and OMB infusion appeared to lower survival rates slightly. This result is significant because it contradicts positive results from our previous small animal studies and places a limit on the efficacy of such treatments for larger animals under more severe respiratory distress. While OMB did not prove efficacious in this rapid-onset ARDS pig model, it may retain potential as a novel therapy for the usual presentation of ARDS in humans, which develops and progresses over days to weeks
    corecore