16 research outputs found

    Atrioventricular nodal reentry tachycardia treatment using CARTO 3 V7 activation mapping: a new era of slow pathway radiofrequency ablation is under coming

    Get PDF
    BackgroundSlow pathway (SP) ablation is the cornerstone for atrioventricular nodal reentry tachycardia (AVNRT) treatment, and a low-voltage bridge offers a good target during mapping using low x-ray exposure. We aimed to assess a new tool to identify SP by activation mapping using the last CARTO3® version, i.e., CARTO PRIME® V7 (Biosense Webster, Diamond Bar, CA, USA)Methods and resultsRight atrial septum and triangle of Koch 3D-activation map were obtained from intracardiac contact mapping during low x-ray CARTO 3® procedure. In 60 patients (mean age 60.3 ± 14.7, 61% females) undergoing ablation for AVNRT, an automatic activation map using a DECANAV® mapping catheter and CARTO® Confidense™, Coherent, and FAM DX software modules were obtained. The SP was identified in all patients as the latest atrioventricular node activation area; RF catheter ablation (RFCA) in that region elicited junctional beats. The mean procedural time was 150.3 ± 48.3 min, the mean fluoroscopy time exposure was 2.9 ± 2 min, the mean dose-area product (DAP) was 16.5 ± 2.7 cGy/cm2. The mean number of RF applications was 3.9 ± 2, the mean ablation index was 428.6 ± 96.6, and the mean contact force was 8 ± 2.8 g. There were no adverse event during the procedure, and no AVNRT recurrences occurred during a mean follow-up of 14.3 ± 8.3 months.ConclusionAblation of the SP by automatic mapping using Confidense™, Coherent, and FAM DX software modules is an innovative, safe, and effective approach to AVNRT ablation. The CARTO3® V7 system shows on a 3D map the latest AV node activation area during sinus rhythm allowing low fluoroscopy time and highly effective RFCA

    Antecedent administration of angiotensin-converting enzyme inhibitors or angiotensin ii receptor antagonists and survival after hospitalization for COVID-19 syndrome

    Get PDF
    Background Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) utilizes the angiotensin-converting enzyme-2 (ACE-2) receptor to enter human cells. Angiotensin-converting enzyme inhibitors (ACEI) and angiotensin II receptor antagonists (ARB) are associated with ACE-2 upregulation. We hypothesized that antecedent use of ACEI/ARB may be associated with mortality in coronavirus disease 2019 (COVID-19). Methods and Results We used the Coracle registry, which contains data of patients hospitalized with COVID-19 in 4 regions of Italy, and restricted analyses to those ≥50 years of age. The primary outcome was in-hospital mortality. Among these 781 patients, 133 (17.0%) used an ARB and 171 (21.9%) used an ACEI. While neither sex nor smoking status differed by user groups, patients on ACEI/ARB were older and more likely to have hypertension, diabetes mellitus, and congestive heart failure. The overall mortality rate was 15.1% (118/781) and increased with age (PTrend<0.0001). The crude odds ratios (ORs) for death for ACEI users and ARB users were 0.98, 95% CI, 0.60-1.60, P=0.9333, and 1.13, 95% CI, 0.67-1.91, P=0.6385, respectively. After adjusting for age, hypertension, diabetes mellitus, and congestive heart failure, antecedent ACEI administration was associated with reduced mortality (OR, 0.55; 95% CI, 0.31-0.98, P=0.0436); a similar, but weaker trend was observed for ARB administration (OR, 0.58; 95% CI, 0.32-1.07, P=0.0796). Conclusions In those aged ≥50 years hospitalized with COVID-19, antecedent use of ACEI was independently associated with reduced risk of inpatient death. Our findings suggest a protective role of renin-angiotensin-aldosterone system inhibition in patients with high cardiovascular risk affected by COVID-19

    Performance of the Durata implantable cardioverter defibrillator lead: results of an independent multicenter study

    No full text
    AIMS: The high rate of implantable cardioverter defibrillator (ICD) lead failures related to the Sprint Fidelis' and Riata's design have raised serious concerns about the reliability of ICD leads. The St. Jude Medical Durata family of leads replaced the preceding Riata line following increased rates of lead failure (1.17% per year). The aim of our study was to evaluate the long-term performance of the Durata lead. METHODS: Eight hundred and eighteen Durata ICD leads were implanted in 11 Italian centers. The incidence of lead failure, defined as a sudden rise in long-term pacing or defibrillation impedance and/or a sudden change in R-wave amplitude and capture thresholds, was assessed. The incidences of lead dislodgment and lead perforation were also evaluated. RESULTS: During a median follow-up of 1353 days (3.7 years; 25-75th interquartile range 806-1887 days) lead failure occurred in 16/818 leads (0.54%/year). The overall survival, free of lead failure, was 98.9% at 3 years, 98.2% at 4 years and 97.5% at 5 years. Lead dislodgment occurred in 12/818 leads with an incidence of 0.4%/year. No cases of cardiac perforation were reported. No major adverse events were reported except for two cases of inappropriate shocks as a consequence of failure or dislodgment. CONCLUSION: Our study suggests that the Durata lead does not engender a higher risk of failure. Overall survival, free from lead failure, was found to be higher than previously reported for the Riata lead

    Vagal reflexes following an exercise stress test: A simple clinical tool for gene-specific risk stratification in the long QT syndrome.

    No full text
    Objectives The study assessed whether heart rate (HR) reduction following an exercise stress test (ExStrT), an easily quantifiable marker of vagal reflexes, might identify high-and low-risk long QT syndrome (LQTS) type 1 (LQT1) patients. Background Identification of LQTS patients more likely to be symptomatic remains elusive. We have previously shown that depressed baroreflex sensitivity, an established marker of reduced vagal reflexes, predicts low probability of symptoms among LQT1. Methods We studied 169 LQTS genotype-positive patients < 50 years of age who performed an ExStrT with the same protocol, on and off beta-blockers including 47 South African LQT1 patients all harboring the KCNQ1-A341V mutation and 122 Italian LQTS patients with impaired (I-Ks-, 66 LQT1) or normal (I-Ks +/-, 50 LQT2 and 6 LQT3) I-Ks current. Results Despite similar maximal HR and workload, by the first minute after cessation of exercise the symptomatic patients in both IKs-groups had a greater HR reduction compared with the asymptomatic (19 +/- 7 beats/min vs. 13 +/- 5 beats/min and 27 +/- 10 beats/min vs. 20 +/- 8 beats/min, both p = 0.009). By contrast, there was no difference between the I-Ks +/- symptomatic and asymptomatic patients (23 +/- 9 beats/min vs. 26 +/- 9 beats/min, p = 0.47). LQT1 patients in the upper tertile for HR reduction had a higher risk of being symptomatic (odds ratio: 3.28, 95% confidence interval: 1.3 to 8.3, p = 0.012). Conclusions HR reduction following exercise identifies LQT1 patients at high or low arrhythmic risk, independently of beta-blocker therapy, and contributes to risk stratification. Intense exercise training, which potentiates vagal reflexes, should probably be avoided by LQT1 patients

    Vagal reflexes following an exercise stress test : A simple clinical tool for gene-specific risk stratification in the Long QT Syndrome

    No full text
    Geneeskunde en GesondheidswetenskappeInterne GeneeskundePlease help us populate SUNScholar with the post print version of this article. It can be e-mailed to: [email protected]
    corecore