49 research outputs found

    Quantum characterization of superconducting photon counters

    Get PDF
    We address the quantum characterization of photon counters based on transition-edge sensors (TESs) and present the first experimental tomography of the positive operator-valued measure (POVM) of a TES. We provide the reliable tomographic reconstruction of the POVM elements up to 11 detected photons and M=100 incoming photons, demonstrating that it is a linear detector.Comment: 3 figures, NJP (to appear

    The prognostic value of 18f-fdg pet imaging at staging in patients with malignant pleural mesothelioma: A literature review

    Get PDF
    Malignant pleural mesothelioma (MPM) is an aggressive malignancy, frequently diagnosed at locally-advanced/metastatic stages. Due to a very poor prognosis and limited treatment options, the need to identify new prognostic markers represents a great clinical challenge. The prognostic role of metabolic information derived from Positron Emission Tomography (PET) with 18F-Fluoro-deoxy-glucose (18F-FDG) has been investigated in different MPM settings, however with no definitive consensus. In this comprehensive review, the prognostic value of FDG-PET imaging exclusively performed at staging in MPM patients was evaluated, conducting a literature search on PubMed/MEDLINE from 2010 to 2020. From the 19 selected studies, despite heterogeneity in several aspects, staging FDG-PET imaging emerges as a valuable prognostic biomarker, with higher tumor uptake predictive of worse prognosis, and with volumetric metabolic parameters like Metabolic Tumor Volume, (MTV) and Total Lesion Glycolisis (TLG) performing better than SUVmax. However, PET uptake parameters were not always confirmed as independent prognostic factors, especially in patients previously treated with pleurodesis and with a non-epithelioid histotype. Future prospective studies in larger and clinically homogeneous populations, and using more standardized methods of PET images analysis, are needed to further validate the value of staging FDG-PET in the prognostic MPM stratification, with a potential impact on better patient-tailored treatment planning, in the perspective of personalized medicine

    A Bio-Imaging Signature as a Predictor of Clinical Outcomes in Locally Advanced Pancreatic Cancer

    Get PDF
    Purpose: To evaluate the predictive value of 18F-FDG PET/CT semiquantitative parameters of the primary tumour and CA 19-9 levels assessed before treatment in patients with locally advanced pancreatic cancer (LAPC). Methods: Among one-hundred twenty patients with LAPC treated at our institution with initial chemotherapy followed by curative chemoradiotherapy (CRT) from July 2013 to January 2019, a secondary analysis with baseline 18F-FDG PET/CT was conducted in fifty-eight patients. Pre-treatment CA 19-9 level and the maximum standardized uptake value (SUVmax), metabolic tumour volume (MTV) and total lesion glycolysis (TLG) of primary tumour were measured. The receiving operating characteristics (ROC) analysis was performed to define the cut-off point of SUVmax, MTV, TLG and CA 19-9 values to use in prediction of early progression (EP), local progression (LP) and overall survival (OS). Areas under the curve (AUCs) were assessed for all variables. Post-test probability was calculated to evaluate the advantage for parameters combination. Results: For EP, CA 19-9 level > 698 U/mL resulted the best marker to identify patient at higher risk with OR of 5.96 (95% CI, 1.66–19.47; p = 0.005) and a Positive Predictive Value (PPV) of 61%. For LP, the most significant parameter was TLG (OR 9.75, 95% CI, 1.64–57.87, p = 0.012), with PPV of 83%. For OS, the most significant parameter was MTV (OR 3.12, 95% CI, 0.9–10.83, p = 0.07) with PPV of 88%. Adding consecutively each of the other parameters, PPV to identify patients at risk resulted further increased (>90%). Conclusions: Pre-treatment CA 19-9 level, as well as MTV and TLG values of primary tumour at baseline 18F-FDG PET/CT and their combination, may represent significant predictors of EP, LP and OS in LAPC patients

    Short 2-[18F]Fluoro-2-Deoxy-D-Glucose PET Dynamic Acquisition Protocol to Evaluate the Influx Rate Constant by Regional Patlak Graphical Analysis in Patients With Non-Small-Cell Lung Cancer

    Get PDF
    Purpose: To test a short 2-[18F]Fluoro-2-deoxy-D-glucose (2-[18F]FDG) PET dynamic acquisition protocol to calculate Ki using regional Patlak graphical analysis in patients with non-small-cell lung cancer (NSCLC). Methods: 24 patients with NSCLC who underwent standard dynamic 2-[18F]FDG acquisitions (60 min) were randomly divided into two groups. In group 1 (n = 10), a population-based image-derived input function (pIDIF) was built using a monoexponential trend (10–60 min), and a leave-one-out cross-validation (LOOCV) method was performed to validate the pIDIF model. In group 2 (n = 14), Ki was obtained by standard regional Patlak plot analysis using IDIF (0–60 min) and tissue response (10–60 min) curves from the volume of interests (VOIs) placed on descending thoracic aorta and tumor tissue, respectively. Moreover, with our method, the Patlak analysis was performed to obtain Ki,s using IDIFFitted curve obtained from PET counts (0–10 min) followed by monoexponential coefficients of pIDIF (10–60 min) and tissue response curve obtained from PET counts at 10 min and between 40 and 60 min, simulating two short dynamic acquisitions. Both IDIF and IDIFFitted curves were modeled to assume the value of 2-[18F]FDG plasma activity measured in the venous blood sampling performed at 45 min in each patient. Spearman's rank correlation, coefficient of determination, and Passing–Bablok regression were used for the comparison between Ki and Ki,s. Finally, Ki,s was obtained with our method in a separate group of patients (group 3, n = 8) that perform two short dynamic acquisitions. Results: Population-based image-derived input function (10–60 min) was modeled with a monoexponential curve with the following fitted parameters obtained in group 1: a = 9.684, b = 16.410, and c = 0.068 min−1. The LOOCV error was 0.4%. In patients of group 2, the mean values of Ki and Ki,s were 0.0442 ± 0.0302 and 0.33 ± 0.0298, respectively (R2 = 0.9970). The Passing–Bablok regression for comparison between Ki and Ki,s showed a slope of 0.992 (95% CI: 0.94–1.06) and intercept value of −0.0003 (95% CI: −0.0033–0.0011). Conclusions: Despite several practical limitations, like the need to position the patient twice and to perform two CT scans, our method contemplates two short 2-[18F]FDG dynamic acquisitions, a population-based input function model, and a late venous blood sample to obtain robust and personalized input function and tissue response curves and to provide reliable regional Ki estimation

    A bio-imaging signature as a predictor of clinical outcomes in locally advanced pancreatic cancer

    Get PDF
    Purpose: To evaluate the predictive value of18F-FDG PET/CT semiquantitative parameters of the primary tumour and CA 19-9 levels assessed before treatment in patients with locally advanced pancreatic cancer (LAPC). Methods: Among one-hundred twenty patients with LAPC treated at our institution with initial chemotherapy followed by curative chemoradiotherapy (CRT) from July 2013 to January 2019, a secondary analysis with baseline18F-FDG PET/CT was conducted in fifty-eight patients. Pre-treatment CA 19-9 level and the maximum standardized uptake value (SUVmax), metabolic tumour volume (MTV) and total lesion glycolysis (TLG) of primary tumour were measured. The receiving operating characteristics (ROC) analysis was performed to define the cut-off point of SUVmax, MTV, TLG and CA 19-9 values to use in prediction of early progression (EP), local progression (LP) and overall survival (OS). Areas under the curve (AUCs) were assessed for all variables. Post-test probability was calculated to evaluate the advantage for parameters combination. Results: For EP, CA 19-9 level > 698 U/mL resulted the best marker to identify patient at higher risk with OR of 5.96 (95% CI, 1.66\u201319.47; p = 0.005) and a Positive Predictive Value (PPV) of 61%. For LP, the most significant parameter was TLG (OR 9.75, 95% CI, 1.64\u201357.87, p = 0.012), with PPV of 83%. For OS, the most significant parameter was MTV (OR 3.12, 95% CI, 0.9\u201310.83, p = 0.07) with PPV of 88%. Adding consecutively each of the other parameters, PPV to identify patients at risk resulted further increased (>90%). Conclusions: Pre-treatment CA 19-9 level, as well as MTV and TLG values of primary tumour at baseline18F-FDG PET/CT and their combination, may represent significant predictors of EP, LP and OS in LAPC patients

    ATHENA X-IFU Demonstration Model: First Joint Operation of the Main TES Array and its Cryogenic AntiCoincidence Detector (CryoAC)

    Get PDF
    The X-IFU is the cryogenic spectrometer onboard the future ATHENA X-ray observatory. It is based on a large array of TES microcalorimeters, which work in combination with a Cryogenic AntiCoincidence detector (CryoAC). This is necessary to reduce the particle background level thus enabling part of the mission science goals. Here we present the first joint test of X-IFU TES array and CryoAC Demonstration Models, performed in a FDM setup. We show that it is possible to operate properly both detectors, and we provide a preliminary demonstration of the anti-coincidence capability of the system achieved by the simultaneous detection of cosmic muons

    The Athena X-ray Integral Field Unit: a consolidated design for the system requirement review of the preliminary definition phase

    Get PDF
    Instrumentatio

    Fabrication of Au/Ti TESs for Optical Photon Counting

    No full text
    High efficiency and negligible dark-count rates of transition-edge sensor (TES) microcalorimeters as single photon detector at telecommunications and optical visible wavelengths make them powerful tools for quantum information and quantum computation. In this work we report details on the fabrication of Au/Ti for photon counting and analyse the effects on the critical temperature and the transition steepness of the structuring process and wiring material. Au/Ti films deposited by electron-beam at substrate temperature lower than 435 K show sharp transition and reproducible Tc. Moreover, we observe that TES with Al wiring are more stable and have better characteristics of TES with Nb wiring. Using 20 micron×20 micron Ti/Au TES single photon detection has been obtained in the UV-visible range
    corecore