20 research outputs found

    Quality of health information for cervical cancer treatment on the internet

    Get PDF
    BACKGROUND: The internet has become a frequently used and powerful tool for patients seeking medical information. This information may not undergo the same quality consideration as the peer-review criteria for publication of information in a journal. The aim of this study is to assess the quality of internet sites providing information on the treatment of cervical cancer, with comparisons between the quality assessments made by an educated lay person and an expert in the field. METHODS: A search of the World Wide Web was made by a lay person to identify sites containing information on the treatment of cervical cancer. The credibility and accuracy of these sites was assessed using predefined criteria based on 'Criteria for Assessing the Quality of Health Information on the Internet' and accepted guidelines for the treatment of cervical cancer. The assessment was made independently and in duplicate by the lay reviewer and medical expert in order to allow comparison. RESULTS: 46 relevant websites were assessed. Only one site contained all the credibility and accuracy criteria, with a further website containing all the credibility criteria. The majority of sites, 38/46, were deemed easy to navigate. The agreement between lay person and expert was good with only 6 items in total changed by the expert. CONCLUSION: This study clearly shows there is wide variation in quality of websites available to patients on the treatment of cervical cancer. Further research and consideration is needed on the effects of website information on gynaecological cancer patients and how steps can be made to insure the posting of good quality information

    The quality of reporting of primary test accuracy studies in obstetrics and gynaecology: application of the STARD criteria

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>In obstetrics and gynaecology there has been a rapid growth in the development of new tests and primary studies of their accuracy. It is imperative that such studies are reported with transparency allowing the detection of any potential bias that may invalidate the results. The objective of this study was to determine the quality of reporting in diagnostic test accuracy studies in obstetrics and gynaecology using the Standards for Reporting of Diagnostic Accuracy - STARD checklist.</p> <p>Methods</p> <p>The included studies of ten systematic reviews were assessed for compliance with each of the reporting criteria. Using appropriate statistical tests we investigated whether there was an improvement in reporting quality since the introduction of the STARD checklist, whether a correlation existed between study sample size, country of origin of study and reporting quality.</p> <p>Results</p> <p>A total of 300 studies were included (195 for obstetrics, 105 for gynaecology). The overall reporting quality of included studies to the STARD criteria was poor. Obstetric studies reported adequately > 50% of the time for 62.1% (18/29) of the items while gynaecologic studies did the same 51.7% (15/29). There was a greater mean compliance with STARD criteria in the included obstetric studies than the gynaecological (p < 0.0001). There was a positive correlation, in both obstetrics (p < 0.0001) and gynaecology (p = 0.0123), between study sample size and reporting quality. No correlation between geographical area of publication and compliance with the reporting criteria could be demonstrated.</p> <p>Conclusions</p> <p>The reporting quality of papers in obstetrics and gynaecology is improving. This may be due to initiatives such as the STARD checklist as well as historical progress in awareness among authors of the need to accurately report studies. There is however considerable scope for further improvement.</p

    A systematic review of tests for lymph node status in primary endometrial cancer

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The lymph node status of a patient is a key determinate in staging, prognosis and adjuvant treatment of endometrial cancer. Despite this, the potential additional morbidity associated with lymphadenectomy makes its role controversial. This study systematically reviews the accuracy literature on sentinel node biopsy; ultra sound scanning, magnetic resonance imaging (MRI) and computer tomography (CT) for determining lymph node status in endometrial cancer.</p> <p>Methods</p> <p>Relevant articles were identified form MEDLINE (1966–2006), EMBASE (1980–2006), MEDION, the Cochrane library, hand searching of reference lists from primary articles and reviews, conference abstracts and contact with experts in the field. The review included 18 relevant primary studies (693 women). Data was extracted for study characteristics and quality. Bivariate random-effect model meta-analysis was used to estimate diagnostic accuracy of the various index tests.</p> <p>Results</p> <p>MRI (pooled positive LR 26.7, 95% CI 10.6 – 67.6 and negative LR 0.29 95% CI 0.17 – 0.49) and successful sentinel node biopsy (pooled positive LR 18.9 95% CI 6.7 – 53.2 and negative LR 0.22, 95% CI 0.1 – 0.48) were the most accurate tests. CT was not as accurate a test (pooled positive LR 3.8, 95% CI 2.0 – 7.3 and negative LR of 0.62, 95% CI 0.45 – 0.86. There was only one study that reported the use of ultrasound scanning.</p> <p>Conclusion</p> <p>MRI and sentinel node biopsy have shown similar diagnostic accuracy in confirming lymph node status among women with primary endometrial cancer than CT scanning, although the comparisons made are indirect and hence subject to bias. MRI should be used in preference, in light of the ASTEC trial, because of its non invasive nature.</p

    Methodological quality of test accuracy studies included in systematic reviews in obstetrics and gynaecology: sources of bias

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Obstetrics and gynaecology have seen rapid growth in the development of new tests with research on these tests presented as diagnostic accuracy studies. To avoid errors in judgement it is important that the methodology of these studies is such that bias is minimised. Our objective was to determine the methodological quality of test accuracy studies in obstetrics and gynaecology using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS) checklist and to assess sources of bias.</p> <p>Methods</p> <p>A prospective protocol was developed to assess the impact of QUADAS on ten systematic reviews performed over the period 2004-2007.We investigated whether there was an improvement in study quality since the introduction of QUADAS, whether a correlation existed between study sample size, country of origin of study and its quality. We also investigated whether there was a correlation between reporting and methodological quality and by the use of meta-regression analyses explored for items of quality that were associated with bias.</p> <p>Results</p> <p>A total of 300 studies were included. The overall quality of included studies was poor (> 50% compliance with 57.1% of quality items). However, the mean compliance with QUADAS showed an improvement post-publication of QUADAS (54.9% versus 61.4% p = 0.002). There was no correlation with study sample size. Gynaecology studies published from the United States of America showed higher quality (USA versus Western Europe p = 0.002; USA versus Asia p = 0.004). Meta-regression analysis showed that no individual quality item had a significant impact on accuracy. There was an association between reporting and methodological quality (r = 0.51 p < 0.0001 for obstetrics and r = 0.56 p < 0.0001 for gynaecology).</p> <p>Conclusions</p> <p>A combination of poor methodological quality and poor reporting affects the inferences that can be drawn from test accuracy studies. Further compliance with quality checklists is required to ensure that bias is minimised.</p

    The Preterm Clinical Network (PCN) Database: a web-based systematic method of collecting data on the care of women at risk of preterm birth

    Get PDF
    Background: Despite much research effort, there is a paucity of conclusive evidence in the field of preterm birth prediction and prevention. The methods of monitoring and prevention strategies offered to women at risk vary considerably around the UK and depend on local maternity care provision. It is becoming increasingly recognised that this experience and knowledge, if captured on a larger scale, could be a utilized as a valuable source of evidence for others. The UK Preterm Clinical Network (UKPCN) was established with the aim of improving care and outcomes for women at risk of preterm birth through the sharing of a wealth of experience and knowledge, as well as the building of clinical and research collaboration. The design and development of a bespoke internet-based database was fundamental to achieving this aim. Method: Following consultation with UKPCN members and agreement on a minimal dataset, the Preterm Clinical Network (PCN) Database was constructed to collect data from women at risk of preterm birth and their children. Information Governance and research ethics committee approval was given for the storage of historical as well as prospectively collected data. Collaborating centres have instant access to their own records, while use of pooled data is governed by the PCN Database Access Committee. Applications are welcomed from UKPCN members and other established research groups. The results of investigations using the data are expected to provide insights into the effectiveness of current surveillance practices and preterm birth interventions on a national and international scale, as well as the generation of ideas for innovation and research. To date, 31 sites are registered as Data Collection Centres, four of which are outside the UK. Conclusion: This paper outlines the aims of the PCN Database along with the development process undertaken from the initial idea to live launch

    Systematic review and meta-analysis of the test accuracy of ductus venosus Doppler to predict compromise of fetal/neonatal wellbeing in high risk pregnancies with placental insufficiency

    No full text
    Objective: To evaluate the test accuracy of ductus venosus Doppler for prediction of compromise of fetal/ neonatal wellbeing. Study design: The search strategy employed searching of electronic databases (Medline, Embase, Cochrane library, Medion) from inception to May 2009, hand searching of journal and reference lists, contact with experts. Two reviewers independently selected articles in which the results of ductus venosus Doppler were associated with the occurrence of compromise of fetal/neonatal wellbeing. There were no language restrictions applied. Data were extracted on study characteristics, quality and results to construct 2 2 tables. Likelihood ratios for positive and negative test results, sensitivity, specificity and their 95% confidence intervals were generated for the different indices and thresholds. Results: Eighteen studies, testing 2267 fetuses met the selection criteria, all performed in a high risk population with placental insufficiency in second/third trimester. Meta-analysis showed moderate predictive accuracy. The best result was for the prediction of perinatal mortality, positive likelihood ratio 4.21 (95% CI 1.98-8.96) and negative likelihood ratio 0.43 (95% CI 0.30-0.61). For prediction of adverse perinatal outcome the results were positive likelihood ratio 3.15 (95% CI 2.19-4.54) and negative likelihood ratio 0.49 (95% CI 0.40-0.59). Conclusion: Abnormal ductus venosus Doppler showed moderate predictive accuracy for compromise of fetal/neonatal wellbeing overall and perinatal mortality in high risk pregnancies with placental insufficiency
    corecore