14 research outputs found

    Comparing spinal blockade effectiveness and maternal hemodynamics using 25 gauge and 29 gauge spinal needles with the same volumetric flow rate in patients undergoing caesarean section

    No full text
    Spinal needles with different diameters can be used to prevent side effects in patients undergoing spinal anaesthesia. However, the velocity of local anaesthetic changes through the spinal needle depending on the diameter of it. Local anaesthetic injection velocity has been reported to be associated with the spinal block level. We aimed to compare spinal needles of different diameters with the same local anaesthetic volumetric flow rate in terms of spinal blockade and hemodynamics in obstetric patients. Eighty-four patients received spinal anaesthesia by either a 25G needle or 29G with the same volumetric flow rate. Block levels, adverse effects, ephedrine given and a success rate of spinal anaesthesia were significantly higher in 25G than in 29G (p < .05). Athough the use of 29G was associated with a low level of block, a sufficient block level was generated for caesarean section. Furthermore, in spite of the technical difficulty, use of 29G was accompanied by a decreased incidence of maternal hypotension, bradycardia and a lowered ephedrine administration.Impact statement Local spinal anaesthetic injections at faster flows cause turbulent flow leading to lower anaesthesia concentrations. The control of spinal anaesthesia levels has some difficulties due to anatomical repositioning, especially in pregnant patients. Also, it can cause frequent hemodynamic complications including hypotension and bradycardia, complications that may also have inadvertent effects on foetus. In this study, we showed that smaller diameter spinal needles provided safer spinal anaesthesia levels and a lower incidence of hemodynamic complications

    Clinical Study The Levels and Duration of Sensory and Motor Blockades of Spinal Anesthesia in Obese Patients That Underwent Urological Operations in the Lithotomy Position

    No full text
    Obesity has a significant effect on the cephalic spread of a spinal block (SB) due to a reduction in cerebrospinal fluid (CSF). SB is controlled by the tissue blood flow in addition to the CSF. Some positions and techniques of surgery used can cause changes in hemodynamics. We investigated effects of hemodynamic changes that may occur during Transurethral prostate resection (TUR-P) and lithotomy position (LP) at the SB level in obese versus nonobese individuals. Sixty patients who had undergone TUR-P operation under spinal anesthesia were divided into a nonobese (BMI &lt; 25 kg/m 2 , Group N) or obese (BMI ≥ 30 kg/m 2 , Group O) group. SB assessments were recorded afterthe LP. SB at 6 and 120 min and the peak SB level were compared between two groups. Hemodynamics were recorded after LP. Peak and 6 min SB levels were similar between the groups, while 120 min SB levels were significantly higher for Group O ( &lt; 0.05). Blood pressure (BP) after the LP was significantly higher for Group N ( &lt; 0.05). LP and TUR-P increased the BP in Group N when compared to Group O. The increase in hemodynamics enhances the blood flow in the spinal cord and may form similar SB levels in nonobese patients to those in obese patients. However, SB time may be longer in obese patients

    A Case Report of Tongue Edema due to Laryngeal Mask with Introducer

    No full text
    Airway management using a laryngeal mask is an especially preferred noninvasive technique because of its achievement of hemodynamic stability and ease of application in surgeries that have short surgery time and do not require specific positions such as the prone position. Although it is easily performed, serious complications may manifest rarely because of lack of experience and inappropriate choice of instrumentation. In this case report, clinical management and treatment options of tongue edema that developed because of the forgotten introducer in laryngeal mask application are presented

    The Levels and Duration of Sensory and Motor Blockades of Spinal Anesthesia in Obese Patients That Underwent Urological Operations in the Lithotomy Position

    No full text
    Obesity has a significant effect on the cephalic spread of a spinal block (SB) due to a reduction in cerebrospinal fluid (CSF). SB is controlled by the tissue blood flow in addition to the CSF. Some positions and techniques of surgery used can cause changes in hemodynamics. We investigated effects of hemodynamic changes that may occur during Transurethral prostate resection (TUR-P) and lithotomy position (LP) at the SB level in obese versus nonobese individuals. Sixty patients who had undergone TUR-P operation under spinal anesthesia were divided into a nonobese (BMI<25 kg/m2, Group N) or obese (BMI≥30 kg/m2, Group O) group. SB assessments were recorded afterthe LP. SB at 6 and 120 min and the peak SB level were compared between two groups. Hemodynamics were recorded after LP. Peak and 6 min SB levels were similar between the groups, while 120 min SB levels were significantly higher for Group O (P<0.05). Blood pressure (BP) after the LP was significantly higher for Group N (P<0.05). LP and TUR-P increased the BP in Group N when compared to Group O. The increase in hemodynamics enhances the blood flow in the spinal cord and may form similar SB levels in nonobese patients to those in obese patients. However, SB time may be longer in obese patients

    Fetal abdominal wall defects: six years experience at a tertiary center.

    No full text
    The authors' aim was to detect the associated anomalies and their effect on the management of the fetuses with omphalocele and gastroschisis. Between the period of 2007-2013, the data of fetuses with abdominal wall defects were analyzed. Chromosomal abnormalities and associated morphologic anomalies diagnosed by ultrasonography and autopsy were evaluated. Of the 61 fetuses, ten (20.4%) omphalocele cases and nine (75%) gastroschisis cases were isolated. Chromosomal abnormalities were found in seven fetuses with omphalocele cases. All fetuses with abnormal karyotypes had multiple additional anomalies. Termination rate was 65.3% for omphalocele group versus none in the gastroschisis group. To give better counseling about the prognosis and outcome of the fetuses with abdominal wall defects, detection of additional anomalies as well as type of the defect are essential tools even if the karyotype is normal

    Prenatal karyotype results of fetuses with nuchal edema, cystic hygroma, and non-immune hydrops

    No full text
    Purpose: Subcutaneous edema detected sonographically in the forms of nuchal edema, cystic hygroma (CH), or non-immune hydrops (NIH) may be a sign of chromosomal abnormalities. The aim of this study was to investigate the chromosome abnormality incidence in fetuses with nuchal edema, CH, or NIH. Materials and Methods: The authors performed cytogenetic analysis of 218 singleton fetuses with ultrasound diagnosis of subcutaneous edema in the forms of nuchal edema in the first and second trimesters. Results: Chromosomal abnormality rates were 30.4, 10.4, 36.8, 34.1, and 60% in the nuchal translucency (NT), nuchal fold thickness (NF), CH, NIH, and CH with NIH groups, respectively. In 71 cases with detected chromosomal abnormalities, 37%, 44%, 15%, and 4% of the pathologic karyotypes were identified as monosomy X, trisomy 21, trisomy 18, and trisomy 13, respectively. Conclusions: This study confirms that subcutaneous edema detected sonographically, in the forms of nuchal edema, CH, or NIH, is a significant indicator of abnormal karyotype and deserves further investigation
    corecore