75 research outputs found

    Sutureless replacement of aortic valves with St Jude Medical mechanical valve prostheses and Nitinol attachment rings: feasibility in long-term (90-day) pig experiments

    Get PDF
    Objective: Nitinol attachment rings (devices) used to attach mechanical aortic valve prostheses suturelessly were studied in long-term (90 days) pig experiments. Methods: The aortic valve was removed and replaced by a device around a St Jude Medical mechanical valve prosthesis in 10 surviving pigs. Supravalvular angiography was done at the end of the operation. No coumarin derivates were given. Results: No or minimal aortic regurgitation was confirmed in all surviving pigs at the end of the operation. Total follow-up was 846 days. In 4 pigs, follow-up was shorter than 90 days (28-75 days); the other 6 pigs did reach 90 days' survival or more. Repeat angiography in 4 pigs at the end of follow-up confirmed the unchanged position of the device at the aortic annulus, without aortic regurgitation. At autopsy, in all pigs the devices proved to be well grown in at the annulus, covered with endothelium, and sometimes tissue overgrowth related to not using coumarin derivates. There was no case of para-device leakage, migration, or embolization. No damage to surrounding anatomic structures or prosthetic valves was found. Conclusions: Nitinol attachment rings can be used to replace the aortic valve suturelessly with St Jude Medical mechanical aortic valve prostheses, without para-device leakage, migration, or damage to the surrounding tissues, in long-term pig experiments during a follow-up of 90 days or more. Refraining from anticoagulation in pigs with mechanical valve prostheses can lead to tissue overgrowth of the valve prosthesis. Further studies are needed to determine long-term feasibility of this method in human beings

    Novel X-ray imaging technology enables significant patient dose reduction in interventional cardiology while maintaining diagnostic image quality

    Get PDF
    Objectives: The purpose of this study was to quantify the reduction in patient radiation dose during coronary angiography (CA) by a new X-ray technology, and to assess its impact on diagnostic image quality. Background: Recently, a novel X-ray imaging technology has become available for interventional cardiology, using advanced image processing and an optimized acquisition chain for radiation dose reduction. Methods: 70 adult patients were randomly assigned to a reference X-ray system or the novel X-ray system. Patient demographics were registered and exposure parameters were recorded for each radiation event. Clinical image quality was assessed for both patient groups. Results: With the same angiographic technique and a comparable patient population, the new imaging technology was associated with a 75% reduction in total kerma-area product (KAP) value (decrease from 47 Gycm(2) to 12 Gycm(2), P<0.001). Clinical image quality showed an equivalent detail and contrast for both imaging systems. On the other hand, the subjective appreciation of noise was more apparent in images of the new image processing system, acquired at lower doses, compared to the reference system. However, the higher noise content did not affect the overall image quality score, which was adequate for diagnosis in both systems. Conclusions: For the first time, we present a new X-ray imaging technology, combining advanced noise reduction algorithms and an optimized acquisition chain, which reduces patient radiation dose in CA drastically (75%), while maintaining diagnostic image quality. Use of this technology may further improve the radiation safety of cardiac angiography and interventions

    Proximal aortic stiffening in Turner patients may be present before dilation can be detected : a segmental functional MRI study

    Get PDF
    Background: To study segmental structural and functional aortic properties in Turner syndrome (TS) patients. Aortic abnormalities contribute to increased morbidity and mortality of women with Turner syndrome. Cardiovascular magnetic resonance (CMR) allows segmental study of aortic elastic properties. Method: We performed Pulse Wave Velocity (PWV) and distensibility measurements using CMR of the thoracic and abdominal aorta in 55 TS-patients, aged 13-59y, and in a control population (n = 38; 12-58y). We investigated the contribution of TS on aortic stiffness in our entire cohort, in bicuspid (BAV) versus tricuspid (TAV) aortic valve-morphology subgroups, and in the younger and older subgroups. Results: Differences in aortic properties were only seen at the most proximal aortic level. BAV Turner patients had significantly higher PWV, compared to TAV Turner (p = 0.014), who in turn had significantly higher PWV compared to controls (p = 0.010). BAV Turner patients had significantly larger ascending aortic (AA) luminal area and lower AA distensibility compared to both controls (all p < 0.01) and TAV Turner patients. TAV Turner had similar AA luminal areas and AA distensibility compared to Controls. Functional changes are present in younger and older Turner subjects, whereas ascending aortic dilation is prominent in older Turner patients. Clinically relevant dilatation (TAV and BAV) was associated with reduced distensibility. Conclusion: Aortic stiffening and dilation in TS affects the proximal aorta, and is more pronounced, although not exclusively, in BAV TS patients. Functional abnormalities are present at an early age, suggesting an aortic wall disease inherent to the TS. Whether this increased stiffness at young age can predict later dilatation needs to be studied longitudinally

    Hufnagel procedure reconverted by endovascular leaflet dislocation and extirpation

    No full text
    Before the development of standard aortic valve replacement, Hufnagel treated aortic insufficiency by implanting a ball-valve prosthesis in the descending thoracic aorta. In a patient who, after four major thoracic procedures, ultimately received two mechanical bileaflet valves in series (one in the ascending and one in the descending aorta), the downstream prosthesis became progressively immobilized, with total blockage of the leaflets in the open position due to insufficient transvalvular negative pressure gradient, After evaluation of this particular situation in an experimental model, we predicted blockage of the downstream prosthesis, once the ascending valve had regained normal function, and easily cleared the blockage of the distal valve by removing the two leaflets using balloon inflation. Normal circulation was clinically restored in three separate steps. (a) Normal function was re-established surgically in the ascending aorta position. (b) A second thoracotomy was avoided by endovascular dislocation of both blocked descending thoracic leaflets through endovascular balloon inflation. (c) Both leaflets embolized to the level of the left common iliac artery, where the nearly intact leaflets were removed. surgically, finally creating a near-normal circulatory situation
    • …