11,538 research outputs found

    Min-Max MSE-based Interference Alignment for Transceiver Designs in Cognitive Radio Networks

    Get PDF
    This paper is concerned with an optimal design of the precoders and receive filters for cognitive radio (CR) networks in which multiple secondary users (SUs) share the same frequency band with multiple primary users (PUs). To cope with interference and to achieve fairness among users, we develop an interference alignment (IA) scheme by minimizing the maximum mean squared error (Min-Max MSE) of the received signals. Since the Min-Max MSE design problems are nonconvex in the design matrix variables of the precoders and receive filters, we develop an alternating optimization algorithm with provable convergence to iteratively find the optimal solutions. In each iteration, the precoder design problems can be recast as second order cone program (SOCP) while the optimal receive filters can be derived in closed-form solutions. Finally, numerical results are provided to demonstrate the superiority of the proposed method as compared to previous work in terms of the information rate and bit error rate

    Photon-meson transition form factors of light pseudoscalar mesons

    Full text link
    The photon-meson transition form factors of light pseudoscalar mesons π0\pi ^{0}, η\eta, and η′\eta ^{\prime} are systematically calculated in a light-cone framework, which is applicable as a light-cone quark model at low Q2Q^{2} and is also physically in accordance with the light-cone pQCD approach at large Q2Q^{2}. The calculated results agree with the available experimental data at high energy scale. We also predict the low Q2Q^{2} behaviors of the photon-meson transition form factors of π0\pi ^{0}, η\eta and η′\eta ^{\prime }, which are measurable in e+A(Nucleus)→e+A+Me+A({Nucleus})\to e+A+M process via Primakoff effect at JLab and DESY.Comment: 22 Latex pages, 7 figures, Version to appear in PR

    Study of Critical Current and n-Values of 2G HTS Tapes: Their Magnetic Field-Angular Dependence

    Get PDF
    Since many applications of YBCO tapes operate in external magnetic fields, it is necessary to investigate the magneto-angular dependence of critical current and n-values in coated conductors. In this paper, five commercial YBCO tapes with different microstructures produced by three different manufacturers are chosen. The selected samples have width of 2.0, 4.0, 4.8, 6.0 or 12mm, with copper, brass or stainless steel laminations. The critical current density dependence Jc (B,θ) and n-values characteristics n(B,θ) of the tapes are comprehensively measured under various magnetic fields and orientations. Afterwards, the obtained experimental data sets are successfully fitted using a novel multi-objective model which considers the material anisotropy. By using this approach a fitting function Ic (B,θ) can always be obtained to accurately describe the experimental data, regardless of the fabrication and width differences of the superconducting tapes. Moreover, our experiment shows that when subject to different external magnetic fields, the angular dependence of n-values characteristics are directly correlated with the corresponding critical current profiles. Our results are helpful to predict the critical current of electromagnetically interacting 2G HTS wires and thereby improving the design and performance of the devices made from YBCO tapes

    Cbx3 inhibits vascular smooth muscle cell proliferation, migration, and neointima formation

    Get PDF
    This work was supported by British Heart Foundation (FS/09/044/28007, PG/11/40/28891, PG/13/45/30326, PG/15/11/31279, PG/15/86/31723, and PG/16/1/31892 to QX). This work forms part of the research portfolio for the National Institute for Health Research Biomedical Research Centre at Barts

    Active Quenching Technique for YBCO Tapes: Quench Acceleration and Protection

    Get PDF
    The application of resistive-type superconducting fault current limiters (RSFCLs) in electrical networks is very attractive due to their relative compactness, light weight, and good performance. However, this technology still has drawbacks: asymmetrical quench, uncertain limiting velocity, passive action, and incapability of enlarging capacity. Here, we present an active quenching technique which can potentially solve these problems. The quenching process is triggered using high frequency (HF) AC fields, which are generated by two coupled copper coils attached on both sides of the YBCO sample. Our experiments show that this approach is effective in guaranteeing uniform quench and therefore is expected to be able to significantly extend the service life of the device. Moreover, the quench speed can be considerably increased by the HF field. We find that the performance of acceleration is positively correlated to the transport current, intensity and frequency of the AC field. In addition, a DC magnetic field is added around the sample holder simultaneously with the AC field, to study the field-angular-frequency dependence of the quench time t(B_AC,f_AC,B_DC,θ_DC). Experimental results prove that the DC magnetic field can cooperate with the HF AC field to accelerate quench, which means better performance can be produced with lower costs with the two fields acting together. In all, this technique showed outstanding performance regarding quench acceleration and tape protection. We believe the HF-assisted quenching technology has a promising future in current limiting devices and hope our findings could be helpful for its potential applications

    Microfluidic impedance biosensors for monitoring a single and multiple cancer cells in anticancer drug treatments

    Get PDF
    In this work, we present a novel microfluidic impedance biosensor chip for trapping both a single and multiple cancer cells and monitoring their response to the anti-cancer drug treatment. By designing different sizes of working microelectrodes together with the V-shaped cell capture structures, a single or multiple cells are trapped on the microelectrodes surfaces. In addition, by utilizing the passive pumping method, cells can be trapped and positioned inside the microchannels without the need of using the outer micro pump or syringe. The impedance change induced by the response of cells to the anticancer drug Cisplatin treatment was successfully recorded. The proposed biosensor chip has a great potential for applications in cancer cell research, drug screening, and quantification of cancer cells from various tumor stages. The results of this study open potential research collaborations about development of cost-effective devices and lab-on-chips for early disease detection, studies of cancerous cells and their response to anti-cancer drugs to optimize cancer treatments, characterisation of mechanical properties of cells, new drug delivery mechanisms, and micro and nano manufacturing
    • …
    corecore