442 research outputs found

    Early bare-metal stent thrombosis presenting with cardiogenic shock: a case report

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>Although stents have improved the safety and efficacy of percutaneous coronary interventions, coronary stent thrombosis remains a serious complication.</p> <p>Case presentation</p> <p>We present the case of a 64-year-old Caucasian man from Greece, with symptoms and electrocardiographic findings suggestive of acute inferior myocardial infarction, who complained of chest pain and rapidly developed cardiogenic shock 48 hours after primary percutaneous coronary intervention.</p> <p>Conclusion</p> <p>The most common cause of early bare-metal stent thrombosis is stent malapposition. Intravascular ultrasound is the preferred method to recognize predictors of coronary events that are not detected by angiography.</p

    Intravascular ultrasound imaging of human coronary arteries in vivo. Analysis of tissue characterizations with comparison to in vitro histological specimens.

    Full text link
    BackgroundIntravascular ultrasound imaging was performed in 27 patients after coronary balloon angioplasty to quantify the lumen and atheroma cross-sectional areas.Methods and resultsA 20-MHz ultrasound catheter was inserted through a 1.6-mm plastic introducer sheath across the dilated area to obtain real-time images at 30 times/sec. The ultrasound images distinguished the lumen from atheroma, calcification, and the muscular media. The presence of dissection between the media and the atheroma was well visualized. These observations of tissue characterization were compared with an in vitro study of 20 human atherosclerotic artery segments that correlated the ultrasound images to histological preparations. The results indicate that high-quality intravascular ultrasound images under controlled in vitro conditions can provide accurate microanatomic information about the histological characteristics of atherosclerotic plaques. Similar quality cross-sectional ultrasound images were also obtained in human coronary arteries in vivo. Quantitative analysis of the ultrasound images from the clinical studies revealed that the mean cross-sectional lumen area after balloon angioplasty was 5.0 +/- 2.0 mm2. The mean residual atheroma area at the level of the prior dilatation was 8.7 +/- 3.4 mm2, which corresponded to 63% of the available arterial cross-sectional area. At the segments of the coronary artery that appeared angiographically normal, the ultrasound images demonstrated the presence of atheroma involving 4.7 +/- 3.2 mm2, which was a mean of 35 +/- 23% of the available area bounded by the media.ConclusionsIntravascular ultrasound appears to be more sensitive than angiography for demonstrating the presence and extent of atherosclerosis and arterial calcification. Intracoronary imaging after balloon angioplasty reveals that a significant amount of atheroma is still present, which may partly explain why the incidence of restenosis is high after percutaneous transluminal coronary angioplasty

    Measuring subluxation of the hemiplegic shoulder: Reliability of a method

    Get PDF
    Objective: Subluxation of the shoulder after stroke can be measured according to the method described by Van Langenberghe and Hogan. Methods: To evaluate the reliability of this method, the shoulder radiographs of 25 patients were available for this study. Two independent raters each assessed these radiographs twice. Results: The intrarater reliability was good: percentage of agreement was 88 and 84%, weighted κ, 0.69 [95% confidence interval (CI), 0.38-1 0] and 0.78 (95% CI, 0.60-0.95) for raters 1 and 2, respectively. The interrater reliability was poor: percentage of agree ment was 36 and 28%, κ, 0.11 (95% CI, 0.0-0.31) and 0.09 (95% CI, 0.0-0.23) in sessions 1 and 2, respectively. Subsequently the original method was adjusted by com bining two categories (no subluxation and beginning subluxation) into one (“no clin ically important subluxation”). Conclusions: After this adjustment of the categories, the interrater reliability improved [percentage of agreement, 72%, and κ, 0.49 (95% CI, 0.18-0.80)], but did not reach acceptable values
    corecore