353 research outputs found

    Circulation of human influenza viruses and emergence of Oseltamivir-resistant A(H1N1) viruses in Cameroon, Central Africa

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>While influenza surveillance has increased in most developing countries in the last few years, little influenza surveillance has been carried out in sub-Saharan Africa and no information is available in Central Africa. The objective of this study was to assess the prevalence of influenza viruses circulating in Yaounde, Cameroon and determine their antigenic and genetic characteristics.</p> <p>Methods</p> <p>Throat and/or nasal swabs were collected from November 2007 to October 2008 from outpatients with influenza-like illness (ILI) in Yaounde, Cameroon and analyzed by two different techniques: a one-step real time reverse transcription-polymerase chain reaction (RT-PCR) and virus isolation in MDCK cells. Typing and subtyping of virus isolates was performed by hemagglutination inhibition (HI), and viruses were sent to the WHO Collaborating Centre in London, UK for further characterization and analyses of antiviral resistance by enzyme inhibition assay and nucleotide sequencing.</p> <p>Results</p> <p>A total of 238 patients with ILI were sampled. During this period 70 (29%) samples were positive for influenza by RT-PCR, of which only 26 (11%) were positive by virus isolation. By HI assay, 20 of the 26 isolates were influenza type A (10 H3N2 and 10 H1N1) and 6 were influenza type B (2 B/Victoria/2/87 lineage and 4 B/Yagamata/16/88 lineage). Seven (70%) of the H1N1 isolates were shown to be resistant to oseltamivir due to a H275Y mutation.</p> <p>Conclusions</p> <p>This study confirmed the circulation of influenza A(H1N1), A(H3N2) and B viruses in the human population in Central Africa and describes the emergence of oseltamivir-resistant A(H1N1) viruses in Central Africa.</p

    Calibration of myocardial T2 and T1 against iron concentration.

    Get PDF
    BACKGROUND: The assessment of myocardial iron using T2* cardiovascular magnetic resonance (CMR) has been validated and calibrated, and is in clinical use. However, there is very limited data assessing the relaxation parameters T1 and T2 for measurement of human myocardial iron. METHODS: Twelve hearts were examined from transfusion-dependent patients: 11 with end-stage heart failure, either following death (n=7) or cardiac transplantation (n=4), and 1 heart from a patient who died from a stroke with no cardiac iron loading. Ex-vivo R1 and R2 measurements (R1=1/T1 and R2=1/T2) at 1.5 Tesla were compared with myocardial iron concentration measured using inductively coupled plasma atomic emission spectroscopy. RESULTS: From a single myocardial slice in formalin which was repeatedly examined, a modest decrease in T2 was observed with time, from mean (± SD) 23.7 ± 0.93 ms at baseline (13 days after death and formalin fixation) to 18.5 ± 1.41 ms at day 566 (p<0.001). Raw T2 values were therefore adjusted to correct for this fall over time. Myocardial R2 was correlated with iron concentration [Fe] (R2 0.566, p<0.001), but the correlation was stronger between LnR2 and Ln[Fe] (R2 0.790, p<0.001). The relation was [Fe] = 5081•(T2)-2.22 between T2 (ms) and myocardial iron (mg/g dry weight). Analysis of T1 proved challenging with a dichotomous distribution of T1, with very short T1 (mean 72.3 ± 25.8 ms) that was independent of iron concentration in all hearts stored in formalin for greater than 12 months. In the remaining hearts stored for <10 weeks prior to scanning, LnR1 and iron concentration were correlated but with marked scatter (R2 0.517, p<0.001). A linear relationship was present between T1 and T2 in the hearts stored for a short period (R2 0.657, p<0.001). CONCLUSION: Myocardial T2 correlates well with myocardial iron concentration, which raises the possibility that T2 may provide additive information to T2* for patients with myocardial siderosis. However, ex-vivo T1 measurements are less reliable due to the severe chemical effects of formalin on T1 shortening, and therefore T1 calibration may only be practical from in-vivo human studies

    Potential use of the Bushmint, Hyptis suaveolens, for the Control of Infestation by the Pink Stalk Borer, Sesamia calamistis on Maize in Southern Benin, West Africa

    Get PDF
    Maize production in Benin, especially in resource-poor farmers' fields, is constrained by stemborers among other factors. One of the major stemborers in southern Benin is Sesamia calamistis Hampson (Lepidoptera: Noctuidae). African farmers cannot afford to use commercial insecticides for controlling stemborers - they are expensive and unsuitable for durable pest management systems due to eco-toxicity. There is therefore a need for cheaper and environmentally friendly methods and botanicals offer an attractive alternative. The bushmint, Hyptis suaveolens (L.) Poit. (Lamiales: Lamiaceae), was compared with the commercial insecticide Furadan (carbofuran) for the control of S. calamistis on maize Zea mays L. (Poales: Poaceae). Trials were conducted in the screenhouse and in the field during the minor cropping season in 2004 at the International Institute of Tropical Agriculture (IITA)-Benin station. The variables measured included numbers of egg masses per plant, eggs per egg mass (in the screenhouse study), population density of S. calamistis, percentage of infested plants and/or ears, and deadhearts in the field. Irrespective of the variable considered, the aqueous extract of H. suaveolens compared favorably with Furadan while maize surrounded by live H. suaveolens plants had lower S. calamistis densities

    Biopsy-based calibration of T2* magnetic resonance for estimation of liver iron concentration and comparison with R2 Ferriscan.

    Get PDF
    BACKGROUND: There is a need to standardise non-invasive measurements of liver iron concentrations (LIC) so clear inferences can be drawn about body iron levels that are associated with hepatic and extra-hepatic complications of iron overload. Since the first demonstration of an inverse relationship between biopsy LIC and liver magnetic resonance (MR) using a proof-of-concept T2* sequence, MR technology has advanced dramatically with a shorter minimum echo-time, closer inter-echo spacing and constant repetition time. These important advances allow more accurate calculation of liver T2* especially in patients with high LIC. METHODS: Here, we used an optimised liver T2* sequence calibrated against 50 liver biopsy samples on 25 patients with transfusional haemosiderosis using ordinary least squares linear regression, and assessed the method reproducibility in 96 scans over an LIC range up to 42 mg/g dry weight (dw) using Bland-Altman plots. Using mixed model linear regression we compared the new T2*-LIC with R2-LIC (Ferriscan) on 92 scans in 54 patients with transfusional haemosiderosis and examined method agreement using Bland-Altman approach. RESULTS: Strong linear correlation between ln(T2*) and ln(LIC) led to the calibration equation LIC = 31.94(T2*)-1.014. This yielded LIC values approximately 2.2 times higher than the proof-of-concept T2* method. Comparing this new T2*-LIC with the R2-LIC (Ferriscan) technique in 92 scans, we observed a close relationship between the two methods for values up to 10 mg/g dw, however the method agreement was poor. CONCLUSIONS: New calibration of T2* against liver biopsy estimates LIC in a reproducible way, correcting the proof-of-concept calibration by 2.2 times. Due to poor agreement, both methods should be used separately to diagnose or rule out liver iron overload in patients with increased ferritin

    Deferasirox (Exjade®) significantly improves cardiac T2* in heavily iron-overloaded patients with β-thalassemia major

    Get PDF
    Noninvasive measurement of tissue iron levels can be assessed using T2* magnetic resonance imaging (MRI) to identify and monitor patients with iron overload. This study monitored cardiac siderosis using T2* MRI in a cohort of 19 heavily iron-overloaded patients with β-thalassemia major receiving iron chelation therapy with deferasirox over an 18-month period. Overall, deferasirox therapy significantly improved mean ± standard deviation cardiac T2* from a baseline of 17.2 ± 10.8 to 21.5 ± 12.8 ms (+25.0%; P = 0.02). A concomitant reduction in median serum ferritin from a baseline of 5,497 to 4,235 ng/mL (−23.0%; P = 0.001), and mean liver iron concentration from 24.2 ± 9.0 to 17.6 ± 12.9 mg Fe/g dry weight (−27.1%; P = 0.01) was also seen. Improvements were seen in patients with various degrees of cardiac siderosis, including those patients with a baseline cardiac T2* of <10 ms, indicative of high cardiac iron burden. These findings therefore support previous observations that deferasirox is effective in the removal of myocardial iron with concomitant reduction in total body iron

    Serologic Cross-Reactivity of Human IgM and IgG Antibodies to Five Species of Ebola Virus

    Get PDF
    Five species of Ebola virus (EBOV) have been identified, with nucleotide differences of 30–45% between species. Four of these species have been shown to cause Ebola hemorrhagic fever (EHF) in humans and a fifth species (Reston ebolavirus) is capable of causing a similar disease in non-human primates. While examining potential serologic cross-reactivity between EBOV species is important for diagnostic assays as well as putative vaccines, the nature of cross-reactive antibodies following EBOV infection has not been thoroughly characterized. In order to examine cross-reactivity of human serologic responses to EBOV, we developed antigen preparations for all five EBOV species, and compared serologic responses by IgM capture and IgG enzyme-linked immunosorbent assay (ELISA) in groups of convalescent diagnostic sera from outbreaks in Kikwit, Democratic Republic of Congo (n = 24), Gulu, Uganda (n = 20), Bundibugyo, Uganda (n = 33), and the Philippines (n = 18), which represent outbreaks due to four different EBOV species. For groups of samples from Kikwit, Gulu, and Bundibugyo, some limited IgM cross-reactivity was noted between heterologous sera-antigen pairs, however, IgM responses were largely stronger against autologous antigen. In some instances IgG responses were higher to autologous antigen than heterologous antigen, however, in contrast to IgM responses, we observed strong cross-reactive IgG antibody responses to heterologous antigens among all sets of samples. Finally, we examined autologous IgM and IgG antibody levels, relative to time following EHF onset, and observed early peaking and declining IgM antibody levels (by 80 days) and early development and persistence of IgG antibodies among all samples, implying a consistent pattern of antibody kinetics, regardless of EBOV species. Our findings demonstrate limited cross-reactivity of IgM antibodies to EBOV, however, the stronger tendency for cross-reactive IgG antibody responses can largely circumvent limitations in the utility of heterologous antigen for diagnostic assays and may assist in the development of antibody-mediated vaccines to EBOV

    A comparison of liver fat fraction measurement on MRI at 3T and 1.5T

    Get PDF
    Purpose Volumetric liver fat fraction (VLFF) measurements were made using the HepaFat-Scan® technique at 1.5T and 3T to determine the agreement between the measurements obtained at the two fields. Methods Sixty patients with type 2 diabetes (67% male, mean age 50.92 ± 6.56yrs) and thirty healthy volunteers (50% male, mean age 48.63 ± 6.32yrs) were scanned on 1.5T Aera and 3T Skyra (Siemens, Erlangen, Germany) MRI scanners on the same day using the HepaFat-Scan® gradient echo protocol with modification of echo times for 3T (TEs 2.38, 4.76, 7.14 ms at 1.5T and 1.2, 2.4, 3.6 ms at 3T). The 3T analyses were performed independently of the 1.5T analyses by a different analyst, blinded from the 1.5T results. Data were analysed for agreement and bias using Bland-Altman methods and intraclass correlation coefficients (ICC). A second cohort of 17 participants underwent interstudy repeatability assessment of VLFF measured by HepaFat-Scan® at 3T. Results A small, but statistically significant mean bias of 0.48% was observed between 3T and 1.5T with 95% limits of agreement -2.2% to 3.2% VLFF. The ICC for agreement between field strengths was 0.983 (95% CI 0.972–0.989). In the repeatability cohort studied at 3T the repeatability coefficient was 4.2%. The ICC for agreement was 0.971 (95% CI 0.921–0.989). Conclusion There is minimal bias and excellent agreement between the measures of VLFF using the HepaFat-Scan® at 1.5 and 3T. The test retest repeatability coefficient at 3T is comparable to the 95% limits of agreement between 1.5T and 3T suggesting that measurements can be made interchangeably between field strengths

    Effect of response format for clinical vignettes on reporting quality of physician practice

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Clinical vignettes have been used widely to compare quality of clinical care and to assess variation in practice, but the effect of different response formats has not been extensively evaluated. Our objective was to compare three clinical vignette-based survey response formats – open-ended questionnaire (A), closed-ended (multiple-choice) questionnaire with deceptive response items mixed with correct items (B), and closed-ended questionnaire with only correct items (C) – in rheumatologists' pre-treatment assessment for tumor-necrosis-factor (TNF) blocker therapy.</p> <p>Methods</p> <p><b><it>Study design</it></b>: Prospective randomized study. <b><it>Setting</it></b>: Rheumatologists attending the 2004 French Society of Rheumatology meeting. Physicians were given a vignette describing the history of a fictitious woman with active rheumatoid arthritis, who was a candidate for therapy with TNF blocking agents, and then were randomized to receive questionnaire A, B, or C, each containing the same four questions but with different response formats, that asked about their pretreatment assessment. <b><it>Measurements</it></b>: Long (recommended items) and short (mandatory items) checklists were developed for pretreatment assessment for TNF-blocker therapy, and scores were expressed on the basis of responses to questionnaires A, B, and C as the percentage of respondents correctly choosing explicit items on these checklists. <b><it>Statistical analysis</it></b>: Comparison of the selected items using pairwise Chi-square tests with Bonferonni correction for variables with statistically significant differences.</p> <p>Results</p> <p>Data for all surveys distributed (114 As, 118 Bs, and 118 Cs) were complete and available for analysis. The percentage of questionnaire A, B, and C respondents for whom data was correctly complete for the short checklist was 50.4%, 84.0% and 95.0%, respectively, and was 0%, 5.0% and 5.9%, respectively, for the long version. As an example, 65.8%, 85.7% and 95.8% of the respondents of A, B, and C questionnaires, respectively, correctly identified the need for tuberculin skin test (p < 0.0001).</p> <p>Conclusion</p> <p>In evaluating clinical practice with use of a clinical vignette, a multiple-choice format rather than an open-ended format overestimates physician performance. The insertion of deceptive response items mixed with correct items in closed-ended (multiple-choice) questionnaire failed to avoid this overestimation.</p
    corecore