168 research outputs found

    The importance of high-throughput cell separation technologies for genomics/proteomics-based clinical diagnostics

    Get PDF
    Gene expression microarray analyses of mixtures of cells approximate a weighted average of the gene expression profiles (GEPs) of each cell type according to its relative abundance in the overall cell sample being analyzed. If the targeted subpopulation of cells is in the minority, or the expected perturbations are marginal, then such changes will be masked by the GEP of the normal/unaffected cells. We show that the GEP of a minor cell subpopulation is often lost when that cell subpopulation is of a frequency less than 30 percent. The GEP is almost always masked by the other cell subpopulations when that frequency drops to 10 percent or less. On the basis of these results one should always assume that the GEP of a given cell subpopulation is probably seriously affected by, the presence of significant numbers of other "contaminating" cell types. Several methodologies can be employed to enrich the target cells submitted for microarray analyses. These include magnetic sorting and laser capture microdissection. If a cell subpopulation of interest is small, very high-throughput cell separation technologies are needed to separate enough cells for conventional microarrays. However, high-throughput flow cytometry/cell sorting overcomes many restrictions of experimental enrichment conditions. This technology can also be used to sort smaller numbers of cells of specific cell subpopulations and subsequently amplify their mRNAs before microarray analyses. When purification techniques are applied to unfixed samples, the potential for changes in gene levels during the process of collection is an additional concern. Since RNA rapidly degrades, and specific mRNAs turn over in minutes or hours, the cell separation process must be very rapid. Hence, high-throughput cell separation (HTS) technologies are needed that can process the necessary number of cells expeditiously in order to avoid such uncontrolled changes in the target cells GEP. In cases where even the use of HTS yields only a small number of cells, the mRNAs (after reverse transcription to cDNA's) must be amplified to yield enough material for conventional microarray analyses. However, the problem of using "microamplification" PCR methods to expand the amount of cDNAs (from mRNAs) is that it is very difficult to amplify equally all of the mRNAs. Unequal amplification leads to a distorted gene expression profile on the microarray. Linear amplifications is difficult to achieve. Unfortunately, present-day gene-chips need to be about 100 times more sensitive than they are now to be able to do many biologically and biomedically meaningful experiments and clinical tests

    Nanoparticle tethered antioxidant response element as a biosensor for oxygen induced toxicity in retinal endothelial cells

    Get PDF
    Purpose: A novel system, based on biosensor DNA tethered to a nanoparticle, was developed for the treatment of retinopathy of prematurity. Methods: The construction of a five-layered nanoparticle was visualized with gel electrophoresis. Transcriptionally active PCR products (TAP) containing the biosensor sequence, were bioconjugated to the surface of magnetic nanoparticles yielding biosensor tethered magnetic nanoparticles (MNP). The biosensor was based on an enhanced green fluorescent protein (EGFP) reporter gene driven by an enhanced antioxidant response element ( ARE). Image analysis and flow cytometry were used to characterize MNP delivery and biosensor activity. Results: The MNP penetrated dividing and migrating cells more often than quiescent endothelial cells in a wound-healing in vitro assay. Prussian blue staining demonstrated that more cells have nanoparticle cores than are transfected. When compared to naked TAP alone, MNP transfected more cells in a dose dependent manner. Both the biosensor alone and MNP induce gene expression in the presence of hyperoxia, greater than 1.5 fold over normoxic controls. These data also show that the MNP had a signal to noise ratio of 0.5 greater than the plasmid form of the biosensor as demonstrated by flow cytometry. Conclusions: This approach has the potential to allow the endothelial cells of the retinal vasculature to prevent or treat themselves after hyperoxic insult, rather than systemic treatment to protect or treat only the retina

    Biosensor-controlled gene therapy/drug delivery with nanoparticles for nanomedicine

    Get PDF
    Nanomedicine involves cell-by-cell regenerative medicine, either repairing cells one at a time or triggering apoptotic pathways in cells that are not repairable. Multilayered nanoparticle systems are being constructed for the targeted delivery of gene therapy to single cells. Cleavable shells containing targeting, biosensing, and gene therapeutic molecules are being constructed to direct nanoparticles to desired intracellular targets. Therapeutic gene sequences are controlled by biosensor-activated control switches to provide the proper amount of gene therapy on a single cell basis. The central idea is to set up gene therapy "nanofactories" inside single living cells. Molecular biosensors linked to these genes control their expression. Gene delivery is started in response to a biosensor detected problem; gene delivery is halted when the cell response indicates that more gene therapy is not needed

    Construction, gene delivery, and expression of DNA tethered nanoparticles

    Get PDF
    PURPOSE: Layered nanoparticles have the potential to deliver any number of substances to cells both in vitro and in vivo. The purpose of this study was to develop and test a relatively simple alternative to custom synthesized nanoparticles for use in multiple biological systems, with special focus on the eye. METHODS: The biotin-labeled transcriptionally active PCR products (TAP) were conjugated to gold, semiconductor nanocrystals, and magnetic nanoparticles (MNP) coated with streptavidin. The process of nanoparticle construction was monitored with gel electrophoresis. Fluorescence microscopy followed by image analysis was used to examine gene expression levels from DNA alone and tethered MNP in human hepatoma derived Huh-7 cells. Adult retinal endothelial cells from both dog (ADREC) and human (HREC) sources were transfected with nanoparticles and reporter gene expression evaluated with confocal and fluorescent microscopy. Transmission electron microscopy was used to quantify the concentration of nanoparticles in a stock solution. Nanoparticles were evaluated for transfection efficiency, determined by fluorescence microscopy cell counts. Cells treated with MNP were evaluated for increased reactive oxygen species (ROS) and necrosis with flow cytometry. RESULTS: Both 5' and 3' biotin-labeled TAP bound equally to MNP and there were no differences in functionality between the two tethering orientations. Free DNA was easily removed by the use of magnetic columns. These particles were also able to deliver genes to a human hepatoma cell line, Huh-7, but transfection efficiency was greater than TAP. The semiconductor nanocrystals and MNP had the highest transfection efficiencies. The MNP did not induce ROS formation or necrosis after 48 h of incubation. CONCLUSIONS: Once transfected, the MNP had reporter gene expression levels equivalent to TAP. The nanoparticles, however, had better transfection efficiencies than TAP. The magnetic nanoparticles were the most easily purified of all the nanoparticles tested. This strategy for bioconjugating TAP to nanoparticles is valuable because nanoparticle composition can be changed and the system optimized quickly. Since endothelial cells take up MNP, this strategy could be used to target neovascularization as occurs in proliferative retinopathies. Multiple cell types were used to test this technology and in each the nanoparticles were capable of transfection. In adult endothelial cells the MNP appeared innocuous, even at the highest doses tested with respect to ROS and necrosis. This technology has the potential to be used as more than just a vector for gene transfer, because each layer has the potential to perform its own unique function and then degrade to expose the next functional layer

    Feasibility study for a numerical aerodynamic simulation facility. Volume 1

    Get PDF
    A Numerical Aerodynamic Simulation Facility (NASF) was designed for the simulation of fluid flow around three-dimensional bodies, both in wind tunnel environments and in free space. The application of numerical simulation to this field of endeavor promised to yield economies in aerodynamic and aircraft body designs. A model for a NASF/FMP (Flow Model Processor) ensemble using a possible approach to meeting NASF goals is presented. The computer hardware and software are presented, along with the entire design and performance analysis and evaluation

    A vaccinia-based single vector construct multi-pathogen vaccine protects against both Zika and chikungunya viruses

    Get PDF
    Zika and chikungunya viruses have caused major epidemics and are transmitted by Aedes aegypti and/or Aedes albopictus mosquitoes. The "Sementis Copenhagen Vector" (SCV) system is a recently developed vaccinia-based, multiplication-defective, vaccine vector technology that allows manufacture in modified CHO cells. Herein we describe a single-vector construct SCV vaccine that encodes the structural polyprotein cassettes of both Zika and chikungunya viruses from different loci. A single vaccination of mice induces neutralizing antibodies to both viruses in wild-type and IFNAR-/- mice and protects against (i) chikungunya virus viremia and arthritis in wild-type mice, (ii) Zika virus viremia and fetal/placental infection in female IFNAR-/- mice, and (iii) Zika virus viremia and testes infection and pathology in male IFNAR-/- mice. To our knowledge this represents the first single-vector construct, multi-pathogen vaccine encoding large polyproteins, and offers both simplified manufacturing and formulation, and reduced "shot burden" for these often co-circulating arboviruses.Natalie A. Prow, Liang Liu, Eri Nakayama, Tamara H. Cooper ... Kerrilyn R. Diener ... John D. Hayball .. et al

    Injection site vaccinology of a recombinant vaccinia-based vector reveals diverse innate immune signatures

    Get PDF
    Poxvirus systems have been extensively used as vaccine vectors. Herein a RNA-Seq analysis of intramuscular injection sites provided detailed insights into host innate immune responses, as well as expression of vector and recombinant immunogen genes, after vaccination with a new multiplication defective, vaccinia-based vector, Sementis Copenhagen Vector. Chikungunya and Zika virus immunogen mRNA and protein expression was associated with necrosing skeletal muscle cells surrounded by mixed cellular infiltrates. The multiple adjuvant signatures at 12 hours post-vaccination were dominated by TLR3, 4 and 9, STING, MAVS, PKR and the inflammasome. Th1 cytokine signatures were dominated by IFNγ, TNF and IL1β, and chemokine signatures by CCL5 and CXCL12. Multiple signatures associated with dendritic cell stimulation were evident. By day seven, vaccine transcripts were absent, and cell death, neutrophil, macrophage and inflammation annotations had abated. No compelling arthritis signatures were identified. Such injection site vaccinology approaches should inform refinements in poxvirus-based vector design.Jessamine E. Hazlewood, Troy Dumenil, Thuy T. Le, Andrii Slonchak, Stephen H. Kazakoff, Ann-Marie Patch ... et al
    corecore