282 research outputs found

    Non-destructive interferometric characterization of an optical dipole trap

    Get PDF
    A method for non-destructive characterization of a dipole trapped atomic sample is presented. It relies on a measurement of the phase-shift imposed by cold atoms on an optical pulse that propagates through a free space Mach-Zehnder interferometer. Using this technique we are able to determine, with very good accuracy, relevant trap parameters such as the atomic sample temperature, trap oscillation frequencies and loss rates. Another important feature is that our method is faster than conventional absorption or fluorescence techniques, allowing the combination of high-dynamical range measurements and a reduced number of spontaneous emission events per atom.Comment: 9 pages, 6 figures, submitted to PR

    Design of a series visco-elastic actuator for multi-purpose rehabilitation haptic device

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Variable structure parallel mechanisms, actuated with low-cost motors with serially added elasticity (series elastic actuator - SEA), has considerable potential in rehabilitation robotics. However, reflected masses of a SEA and variable structure parallel mechanism linked with a compliant actuator result in a potentially unstable coupled mechanical oscillator, which has not been addressed in previous studies.</p> <p>Methods</p> <p>The aim of this paper was to investigate through simulation, experimentation and theoretical analysis the necessary conditions that guarantee stability and passivity of a haptic device (based on a variable structure parallel mechanism driven by SEA actuators) when in contact with a human. We have analyzed an equivalent mechanical system where a dissipative element, a mechanical damper was placed in parallel to a spring in SEA.</p> <p>Results</p> <p>The theoretical analysis yielded necessary conditions relating the damping coefficient, spring stiffness, both reflected masses, controller's gain and desired virtual impedance that needs to be fulfilled in order to obtain stable and passive behavior of the device when in contact with a human. The validity of the derived passivity conditions were confirmed in simulations and experimentally.</p> <p>Conclusions</p> <p>These results show that by properly designing variable structure parallel mechanisms actuated with SEA, versatile and affordable rehabilitation robotic devices can be conceived, which may facilitate their wide spread use in clinical and home environments.</p

    Highly multimode memory in a crystal

    Full text link
    We experimentally demonstrate the storage of 1060 temporal modes onto a thulium-doped crystal using an atomic frequency comb (AFC). The comb covers 0.93 GHz defining the storage bandwidth. As compared to previous AFC preparation methods (pulse sequences i.e. amplitude modulation), we only use frequency modulation to produce the desired optical pumping spectrum. To ensure an accurate spectrally selective optical pumping, the frequency modulated laser is self-locked on the atomic comb. Our approach is general and should be applicable to a wide range of rare-earth doped material in the context of multimode quantum memory

    Improving preclinical to clinical translation in Alzheimer\u27s disease research.

    Get PDF
    Introduction: Preclinical testing in animal models is a critical component of the drug discovery and development process. While hundreds of interventions have demonstrated preclinical efficacy for ameliorating cognitive impairments in animal models, none have confirmed efficacy in Alzheimer\u27s disease (AD) clinical trials. Critically this lack of translation to the clinic points in part to issues with the animal models, the preclinical assays used, and lack of scientific rigor and reproducibility during execution. In an effort to improve this translation, the Preclinical Testing Core (PTC) of the Model Organism Development and Evaluation for Late-onset AD (MODEL-AD) consortium has established a rigorous screening strategy with go/no-go decision points that permits unbiased assessments of therapeutic agents. Methods: An initial screen evaluates drug stability, formulation, and pharmacokinetics (PK) to confirm appreciable brain exposure in the disease model at the pathologically relevant ages, followed by pharmacodynamics (PD) and predictive PK/PD modeling to inform the dose regimen for long-term studies. The secondary screen evaluates target engagement and disease modifying activity using non-invasive positron emission tomography/magnetic resonance imaging (PET/MRI). Provided the compound meets its go criteria for these endpoints, evaluation for efficacy on behavioral endpoints are conducted. Results: Validation of this pipeline using tool compounds revealed the importance of critical quality control (QC) steps that researchers need to be aware of when executing preclinical studies. These include confirmation of the active pharmaceutical ingredient and at the precise concentration expected; and an experimental design that is well powered and in line with the Animal Research Reporting of In vivo Experiments (ARRIVE) guidelines. Discussion: Taken together our experience executing a rigorous screening strategy with QC checkpoints provides insight to the challenges of conducting translational studies in animal models. The PTC pipeline is a National Institute on Aging (NIA)-supported resource accessible to the research community for investigators to nominate compounds for testing (https://stopadportal.synapse.org/), and these resources will ultimately enable better translational studies to be conducted

    Rotating Higher Spin Partition Functions and Extended BMS Symmetries

    Get PDF
    We evaluate one-loop partition functions of higher-spin fields in thermal flat space with angular potentials; this computation is performed in arbitrary space-time dimension, and the result is a simple combination of Poincar\'e characters. We then focus on dimension three, showing that suitable products of one-loop partition functions coincide with vacuum characters of higher-spin asymptotic symmetry algebras at null infinity. These are extensions of the bms_3 algebra that emerges in pure gravity, and we propose a way to build their unitary representations and to compute the associated characters. We also extend our investigations to supergravity and to a class of gauge theories involving higher-spin fermionic fields.Comment: 58 pages; clarifications and references added; version to be published in JHE

    Development of a Novel Hematological Malignancy Specific Patient-Reported Outcome Measure (HM-PRO) : Content Validity

    Get PDF
    Copyright © 2020 Goswami, Oliva, Ionova, Else, Kell, Fielding, Jennings, Karakantza, Al-Ismail, Collins, McConnell, Langton and Salek.Background: The quality of life of patients at all stages of hematological malignancy is greatly affected by the disease and its treatment. There is a wide range of health-related quality of life (HRQoL) issues important to these patients. Any new instrument developed to measure HRQoL of such patients should be content valid, i.e., the items should be comprehensively relevant to the patients and their health condition. The aim of the present study was to examine content validity of a hematological malignancy specific patient reported outcome measure (HM-PRO) developed for use in routine clinical practice. Methods: Following literature review and semi-structured interviews, the generated themes and sub-themes were discussed to develop the prototype version of the HM-PRO. A 4-step approach was used for content validation: initial testing and cognitive interviewing; item rating; content validity panel meeting; final field testing and cognitive interviewing. Additional questions related to patients' perception of recall period and preferred sentence structure (i.e., question or statement) of the items were also asked during cognitive interviews. Results: The content analysis of 129 transcribed semi-structured interviews resulted in the prototype version of the instrument consisting of 58 items grouped into two parts: Part A (impact/HRQoL - 34 items) and Part B (signs and symptoms - 24 items). The initial testing showed intra-class correlation coefficient (ICC) of >0.8 for both Part A and Part B. Item rating for language clarity, completeness, relevance, and response scale by experts and patients showed content validity index for scales average >0.8 for both Part A and Part B, except 0.64 for relevance for Part A by the patient panel. The final testing of the revised version of the instrument showed the Cronbach's alpha value of 0.91 for Part A and 0.76 for Part B, suggesting high internal consistency, and ICC of 0.91 for Part A and 0.76 for Part B. The recall period of "today" for Part-A and "last 3 days" for Part-B were the patients' preferred "recall period." Furthermore, the patients expressed preference to the HM-PRO items as statements. Conclusion: The findings of this study confirm that the HM-PRO possesses a strong content validity, includes all the issues important to patients and is easy to read, understand and respond to spontaneously.Peer reviewedFinal Published versio
    corecore