205 research outputs found

    Self-occluding Candy-Plug: Implantation Technique to Obtain False Lumen Thrombosis in Chronic Aortic Dissections

    Get PDF
    Purpose: To describe the implantation steps of the latest generation of candy-plug device (third CP generation [CP III]) and to illustrate its possible pitfalls by discussing a case in whom this device was employed to occlude the false lumen (FL) of a chronic type B aortic dissection. Technique: A 69 year-old male patient who underwent a frozen elephant trunk arch repair due to residual type A aortic dissection developed a FL aneurysmal degeneration limited to the descending thoracic aorta. Two thoracic stent-grafts were deployed into the true lumen up to the celiac trunk origin. Then, the FL was occluded with a self-occluding CP III device (Cook Medical, Bloomington, Indiana), placed at the same level as the distal thoracic stent-graft. The distal un-stented sleeve was pushed upward to allow immediate occlusion of its central lumen, avoiding interference with reno-visceral arteries arising from the FL. Both intraoperative transesophageal echocardiography and follow-up computed tomographic angiography scan demonstrated complete FL thrombosis. Conclusion: The introduction of CP III with its self-occluding mechanism helped to shorten and standardize the procedure. However, adjunctive steps may be needed to immediately obtain FL occlusion and avoid hampering the perfusion of vessels arising from the FL

    The open future, bivalence and assertion

    Get PDF
    It is highly intuitive that the future is open and the past is closed—whereas it is unsettled whether there will be a fourth world war, it is settled that there was a first. Recently, it has become increasingly popular to claim that the intuitive openness of the future implies that contingent statements about the future, such as ‘there will be a sea battle tomorrow,’ are non-bivalent (neither true nor false). In this paper, we argue that the non-bivalence of future contingents is at odds with our pre-theoretic intuitions about the openness of the future. These are revealed by our pragmatic judgments concerning the correctness and incorrectness of assertions of future contingents. We argue that the pragmatic data together with a plausible account of assertion shows that in many cases we take future contingents to be true (or to be false), though we take the future to be open in relevant respects. It follows that appeals to intuition to support the non-bivalence of future contingents is untenable. Intuition favours bivalence

    Dialetheism in Action: A New Strategy for Solving the Equal Validity Paradox

    Get PDF
    This paper starts from the Equal Validity Paradox, a paradoxical argument connected to the so-called phenomenon of faultless disagreement. It is argued that there are at least six strategies for solving the paradox. After presenting the first five strategies and their main problems, the paper focuses on the sixth strategy which rejects the assumption that every proposition cannot be both true a false. Dialetheism is the natural candidate for developing strategy six. After presenting strategy six in detail, we formulate a normative problem for the dialetheist and offer a tentative solution to it. We then elaborate further considerations connecting strategy six to pluralism about truth and logic. Even if strategy six is a hard path to take, its scrutiny highlights some important points on truth, logic and the norms for acceptance and rejection

    Results of Iliac Branch Devices in Octogenarians Within the pELVIS Registry

    Get PDF
    Purpose:To evaluate if the elderly could benefit from the implantation of iliac branch devices (IBDs) to preserve the patency of the internal iliac artery (IIA) in aneurysms involving the iliac bifurcation.Materials and Methods:From January 2005 to April 2017, 804 patients enrolled in the pELVIS registry underwent endovascular aneurysm repair with 910 IBDs due to aneurysmal involvement of the iliac bifurcation. Among the 804 patients, 157 (19.5%) were octogenarians (mean age 82.9 +/- 2.5 years; 157 men) with 171 target IIAs for preservation. Outcomes at 30 days included technical success, death, conversion to open surgery, and major complications. Outcomes evaluated in follow-up were patency of the IBD and target vessels, type I and type III endoleaks, aneurysm-related reinterventions, aneurysm-related death, and overall patient survival. Kaplan-Meier analyses were employed to evaluate the late outcome measures; the estimates are presented with the 95% confidence interval (CI).Results:Technical success was 99.4% with no intraoperative conversions or deaths (1 bridging stent could not be implanted, and the IIA was sacrificed). Perioperative mortality was 1.9%. The overall perioperative aneurysm-related complication rate was 8.9% (14/157), with an early reintervention rate of 5.1% (8/157). Median postoperative radiological and clinical follow-up were 21.8 months (range 1-127) and 29.3 months (range 1-127), respectively. Estimated rates of freedom from occlusion of the IBD, the IIA, and the external iliac artery at 60 months were 97.7% (95% CI 96.1% to 99.3%), 97.3% (95% CI 95.7% to 98.9%), and 98.6% (95% CI 97% to 99.9%), respectively. Estimated rates of freedom from type I and type III endoleaks and device migration at 60 months were 90.9% (95% CI 87% to 94.3%), 98.7% (95% CI 97.5% to 99.8%), and 98% (95% CI 96.4% to 99.6%), respectively. Freedom from all cause reintervention at 60 months was 87.4% (95% CI 82.6% to 92.2%). The estimated overall survival rate at 60 months was 59% (95% CI 52.4% to 65.6%).Conclusion:IBD implantation in octogenarians provided acceptable perioperative mortality and morbidity rates, with satisfying long-term freedom from IBD-related complications and should be considered a feasible repair option for selected elderly patients affected by aneurysms involving the iliac bifurcation

    Editor's Choice - Infective Native Aortic Aneurysms: A Delphi Consensus Document on Terminology, Definition, Classification, Diagnosis, and Reporting Standards.

    Get PDF
    There is no consensus regarding the terminology, definition, classification, diagnostic criteria, and algorithm, or reporting standards for the disease of infective native aortic aneurysm (INAA), previously known as mycotic aneurysm. The aim of this study was to establish this by performing a consensus study. The Delphi methodology was used. Thirty-seven international experts were invited via mail to participate. Four two week Delphi rounds were performed, using an online questionnaire, initially with 22 statements and nine reporting items. The panellists rated the statements on a five point Likert scale. Comments on statements were analysed, statements revised, and results presented in iterative rounds. Consensus was defined as ≥ 75% of the panel selecting "strongly agree" or "agree" on the Likert scale, and consensus on the final assessment was defined as Cronbach's alpha coefficient > .80. All 38 panellists completed all four rounds, resulting in 100% participation and agreement that this study was necessary, and the term INAA was agreed to be optimal. Three more statements were added based on the results and comments of the panel, resulting in a final 25 statements and nine reporting items. All 25 statements reached an agreement of ≥ 87%, and all nine reporting items reached an agreement of 100%. The Cronbach's alpha increased for each consecutive round (round 1 = .84, round 2 = .87, round 3 = .90, and round 4 = .92). Thus, consensus was reached for all statements and reporting items. This Delphi study established the first consensus document on INAA regarding terminology, definition, classification, diagnostic criteria, and algorithm, as well as reporting standards. The results of this study create essential conditions for scientific research on this disease. The presented consensus will need future amendments in accordance with newly acquired knowledge

    Zeolite-like liquid crystals

    Get PDF
    Zeolites represent inorganic solid-state materials with porous structures of fascinating complexity. Recently, significant progress was made by reticular synthesis of related organic solid-state materials, such as metal-organic or covalent organic frameworks. Herein we go a step further and report the first example of a fluid honeycomb mimicking a zeolitic framework. In this unique self-assembled liquid crystalline structure, transverse-lying π-conjugated rod-like molecules form pentagonal channels, encircling larger octagonal channels, a structural motif also found in some zeolites. Additional bundles of coaxial molecules penetrate the centres of the larger channels, unreachable by chains attached to the honeycomb framework. This creates a unique fluid hybrid structure combining positive and negative anisotropies, providing the potential for tuning the directionality of anisotropic optical, electrical and magnetic properties. This work also demonstrates a new approach to complex soft-matter self-assembly, by using frustration between space filling and the entropic penalty of chain extension

    Endovascular Stent Treatment for Symptomatic Benign Iliofemoral Venous Occlusive Disease: Long-Term Results 1987–2009

    Get PDF
    Venous stenting has been shown to effectively treat iliofemoral venous obstruction with good short- and mid-term results. The aim of this study was to investigate long-term clinical outcome and stent patency. Twenty patients were treated with venous stenting for benign disease at our institution between 1987 and 2005. Fifteen of 20 patients (15 female, mean age at time of stent implantation 38 years [range 18–66]) returned for a clinical visit, a plain X-ray of the stent, and a Duplex ultrasound. Four patients were lost to follow-up, and one patient died 277 months after stent placement although a good clinical result was documented 267 months after stent placement. Mean follow-up after stent placement was 167.8 months (13.9 years) (range 71 (6 years) to 267 months [22 years]). No patient needed an additional venous intervention after stent implantation. No significant difference between the circumference of the thigh on the stented side (mean 55.1 cm [range 47.0–70.0]) compared with the contralateral thigh (mean 54.9 cm [range 47.0–70.0]) (p = 0.684) was seen. There was a nonsignificant trend toward higher flow velocities within the stent (mean 30.8 cm/s [range 10.0–48.0]) and the corresponding vein segment on the contralateral side (mean 25.2 cm/s [range 12.0–47.0]) (p = 0.065). Stent integrity was confirmed in 14 of 15 cases. Only one stent showed a fracture, as documented on x-ray, without any impairment of flow. Venous stenting using Wallstents showed excellent long-term clinical outcome and primary patency rate

    Comparison of single- and multistage strategies during fenestrated-branched endovascular aortic repair of thoracoabdominal aortic aneurysms

    Get PDF
    Objective: The aim of this study was to compare outcomes of single or multistage approach during fenestrated-branched endovascular aortic repair (FB-EVAR) of extensive thoracoabdominal aortic aneurysms (TAAAs). Methods: We reviewed the clinical data of consecutive patients treated by FB-EVAR for extent I to III TAAAs in 24 centers (2006-2021). All patients received a single brand manufactured patient-specific or off-the-shelf fenestrated-branched stent grafts. Staging strategies included proximal thoracic aortic repair, minimally invasive segmental artery coil embolization, temporary aneurysm sac perfusion and combinations of these techniques. Endpoints were analyzed for elective repair in patients who had a single- or multistage approach before and after propensity score adjustment for baseline differences, including the composite 30-day/in-hospital mortality and/or permanent paraplegia, major adverse event, patient survival, and freedom from aortic-related mortality. Results: A total of 1947 patients (65% male; mean age, 71 ± 8 years) underwent FB-EVAR of 155 extent I (10%), 729 extent II (46%), and 713 extent III TAAAs (44%). A single-stage approach was used in 939 patients (48%) and a multistage approach in 1008 patients (52%). A multistage approach was more frequently used in patients undergoing elective compared with non-elective repair (55% vs 35%; P < .001). Staging strategies were proximal thoracic aortic repair in 743 patients (74%), temporary aneurysm sac perfusion in 128 (13%), minimally invasive segmental artery coil embolization in 10 (1%), and combinations in 127 (12%). Among patients undergoing elective repair (n = 1597), the composite endpoint of 30-day/in-hospital mortality and/or permanent paraplegia rate occurred in 14% of single-stage and 6% of multistage approach patients (P < .001). After adjustment with a propensity score, multistage approach was associated with lower rates of 30-day/in-hospital mortality and/or permanent paraplegia (odds ratio, 0.466; 95% confidence interval, 0.271-0.801; P = .006) and higher patient survival at 1 year (86.9±1.3% vs 79.6±1.7%) and 3 years (72.7±2.1% vs 64.2±2.3%; adjusted hazard ratio, 0.714; 95% confidence interval, 0.528-0.966; P = .029), compared with a single stage approach. Conclusions: Staging elective FB-EVAR of extent I to III TAAAs was associated with decreased risk of mortality and/or permanent paraplegia at 30 days or within hospital stay, and with higher patient survival at 1 and 3 years
    corecore