502 research outputs found

    Optimized Integration of Renewable Energies into Existing Power Plant Portfolios

    Get PDF
    AbstractFossil fuel importing as well as exporting countries of the MENA region have recognized their enormous potential of power generation by renewable energy (RE) technologies and the associated benefit for their national budgets, and therefore have formulated ambitious targets for RE deployment. However, only few countries have a detailed master plan that shows how RE technologies can be integrated efficiently into their existing power plant portfolio. Capacity expansion of RE and conventional technologies must be adjusted and optimized in order to minimize total generation costs of the entire system while maintaining security of supply. Within the last three years, DLR has developed the capacity expansion and unit commitment optimization model REMix-CEM (Renewable Energy Mix – Capacity Expansion Model) in order to support authorities of the MENA region in the process of integrating RE technologies efficiently in the short-term and transforming their strongly growing fossil-fuel dominated power systems of today towards higher RE shares. REMix-CEM optimizes the capacity expansion of conventional and RE technologies from a state-owned utility perspective starting from the existing power plant portfolio by modeling the hourly performance of each single existing and candidate unit. The paper presents an overview of the developed methodology as well as the characteristics and capabilities of REMix-CEM by presenting a case study for the electricity sector of the Hashemite Kingdom of Jordan for the years 2013 – 2020

    A comparative analysis using flowmeter, laser-Doppler spectrophotometry, and indocyanine green-videoangiography for detection of vascular tenosis in free flaps

    Get PDF
    The effects of gradual vascular occlusion on the blood supply of perfused areas are poorly described. Information relating to the comparison of flap monitoring techniques is lacking. Varying stenotic conditions (0%, 25%, 50%, 75% and 100%) were generated on purpose at the A. and V. femoralis in the rat model. Analyses included flowmeter, simultaneous laser-Doppler flowmetry and tissue spectrophotometry (O2C) and indocyanine green- (ICG-) videoangiography with integrated FLOW 800 tool. A Random Forests prediction model was used to analyse the importance of each method to diagnose the stenotic conditions. The ability to discriminate and to accurately estimate the probability of stenosis was assessed by Receiver Operating Characteristic (ROC) curves and calibration plots. Blood flow changes for all modalities were described in detail. Flowmeter displayed earliest a linear decrease as a result of increasing stenosis. A stenosis of 50% degrees was most difficult to detect correctly. The combination of flowmeter and ICG-videoangiography showed high diagnostic power for each stenotic situation (area under the ROC > 0.79). Flowmeter and ICG-videoangiography showed to be most relevant in detection of varying stenotic conditions and may change the clinical outcome. The O2C showed less effect on varying stenotic situations as the only surface monitoring device

    Learning from Sustainability-Oriented Innovation

    Get PDF
    This chapter argues that insights from the realm of sustainability-oriented innovation can provide useful answers to the question of why Small and Medium-Sized Enterprises (SMEs) would (or should) become interested in implementing responsible innovation practices. It is based on the assumption that “responsible innovation” and “sustainability-oriented innovation” are different approaches aimed at orienting innovation towards increased positive impacts on social and natural environments. Motivations and influences for pursuing sustainability-oriented inno-vation have been studied in the past, and can provide insights into reasons for pursu-ing the implementation of responsible innovation practices

    Materials and structures

    Get PDF
    Materials and structures technology covers a wide range of technical areas. Some of the most pertinent issues for the Astrotech 21 missions include dimensionally stable structural materials, advanced composites, dielectric coatings, optical metallic coatings for low scattered light applications, low scattered light surfaces, deployable and inflatable structures (including optical), support structures in 0-g and 1-g environments, cryogenic optics, optical blacks, contamination hardened surfaces, radiation hardened glasses and crystals, mono-metallic telescopes and instruments, and materials characterization. Some specific examples include low coefficients of thermal expansion (CTE) structures (0.01 ppm/K), lightweight thermally stable mirror materials, thermally stable optical assemblies, high reliability/accuracy (1 micron) deployable structures, and characterization of nanometer level behavior of materials/structures for interferometry concepts. Large filled-aperture concepts will require materials with CTE's of 10(exp 9) at 80 K, anti-contamination coatings, deployable and erectable structures, composite materials with CTE's less than 0.01 ppm/K and thermal hysteresis, 0.001 ppm/K. Gravitational detection systems such as LAGOS will require rigid/deployable structures, dimensionally stable components, lightweight materials with low conductivity, and high stability optics. The Materials and Structures panel addressed these issues and the relevance of the Astrotech 21 mission requirements by dividing materials and structures technology into five categories. These categories, the necessary development, and applicable mission/program development phasing are summarized. For each of these areas, technology assessments were made and development plans were defined

    Detection of thrombosis in microvessels with indocyanine green videoangiography

    Get PDF
    Atherosclerosis is a systemic condition that is responsible for many diseases, and becomes a problem in cases where plaques form at several sites. The formation of a thrombotic embolus may jeopardise vascular operations, including microvascular anastomoses in replantation procedures or free tissue transfers. A mobile imaging tool for the detection of thrombosis preoperatively or intraoperatively would be valuable. An intimal injury, simulating removal of atherosclerotic plaques, was made microsurgically in 60 rat aortas, and results were analysed macroscopically, histologically, and with intraoperative indocyanine green (ICG) videoangiography immediately postoperatively. The Spearman and Pearson correlation tests were used to compare the three techniques. The sensitivity and specificity of ICG videoangiography was calculated in relation to both macroscopic and histological results. Detection of thrombosis was possible in 25 cases, and in 18 cases no thrombosis was correctly diagnosed by all methods used. In 31 of 60 specimens formation of thrombus was detected histologically, and in 29 of 60 examinations it was detected clinically, which yielded a correlation of 93.5% between the two examinations. Macroscopic analysis correlated better with ICG videoangiography (sensitivity 86.2% and specificity 64.5%) than histological observations (sensitivity 80.6% and specificity 62.1%). There was a significant correlation among all comparisons (each p ≀ 0.001) with correlation indexes of 0.94, 0.52, and 0.44 for macroscopic/histological, clinical/ICG videoangiographic, and ICG videoangiographic/histological results, respectively. Our results show that ICG videoangiography is an important method for the detection of formation of acute thrombi and may be an important tool in vascular procedures

    Acceleration disturbances and requirements for ASTROD I

    Full text link
    ASTRODynamical Space Test of Relativity using Optical Devices I (ASTROD I) mainly aims at testing relativistic gravity and measuring the solar-system parameters with high precision, by carrying out laser ranging between a spacecraft in a solar orbit and ground stations. In order to achieve these goals, the magnitude of the total acceleration disturbance of the proof mass has to be less than 10−13 m s−2 Hz−1/2 at 0.1 m Hz. In this paper, we give a preliminary overview of the sources and magnitude of acceleration disturbances that could arise in the ASTROD I proof mass. Based on the estimates of the acceleration disturbances and by assuming a simple controlloop model, we infer requirements for ASTROD I. Our estimates show that most of the requirements for ASTROD I can be relaxed in comparison with Laser Interferometer Space Antenna (LISA).Comment: 19 pages, two figures, accepted for publication by Class. Quantum Grav. (at press

    Prediction of Flap Necrosis by Using Indocyanine Green Videoangiography in Cases of Venous Occlusion in the Epigastric Flap Model of the Rat

    Get PDF
    Background A compromised free flap perfusion attributable to vascular occlusion requires immediate operative correction. Indocyanine green (ICG) videoangiography may reduce the risk of partial skin flap necrosis in high-risk free flaps in patients undergoing head and neck reconstruction. The purpose of this study was to determine the role of ICG in cases of venous congestion in a rat model. Methods A standardized epigastric flap was raised and repositioned in 35 rats. Full venous occlusion of the draining superficial inferior epigastric vein was temporarily applied for 4, 5, 6, or 7 hours. Blood flow measurements including simultaneous laser-Doppler flowmetry and tissue spectrophotometry (oxygen-to-see [O2C]) and ICG videoangiography with the FLOW 800 tool were performed before flap raising, after temporary venous stasis, and after clinical monitoring for 1 week. The Youden index computed from the receiver operating characteristic curve was used to define an optimal cutoff value for necrosis prediction after 4 and 6 hours of stasis. Results The ICG videoangiography with the FLOW 800 tool was found to be superior to O2C in the prediction of flap necrosis. The accuracy of prediction was moderate after an interval of 4 hours of stasis (area under the curve [AUC] = 0.661; 95% confidence interval [CI]: 0.489–0.834) and good after 6 hours of stasis (AUC = 0.787; 95% CI: 0.65–0.915). Conclusions The O2C does not reliably predict tissue necrosis in cases of venous congestion. ICG videoangiography is a valuable tool that can predict clinical outcome and provide guidance on whether to salvage a congested flap

    Examining a staging model for anorexia nervosa: empirical exploration of a four stage model of severity.

    Get PDF
    Background: An illness staging model for anorexia nervosa (AN) has received increasing attention, but assessing the merits of this concept is dependent on empirically examining a model in clinical samples. Building on preliminary findings regarding the reliability and validity of the Clinician Administered Staging Instrument for Anorexia Nervosa (CASIAN), the current study explores operationalising CASIAN severity scores into stages and assesses their relationship with other clinical features. Method: In women with DSM-IV-R AN and sub-threshold AN (all met AN criteria using DSM 5), receiver operating curve (ROC) analysis (n = 67) assessed the relationship between the sensitivity and specificity of each stage of the CASIAN. Thereafter chi-square and post-hoc adjusted residual analysis provided a preliminary assessment of the validity of the stages comparing the relationship between stage and treatment intensity and AN sub-types, and explored movement between stages after six months (Time 3) in a larger cohort (n = 171). Results: The CASIAN significantly distinguished between milder stages of illness (Stage 1 and 2) versus more severe stages of illness (Stages 3 and 4), and approached statistical significance in distinguishing each of the four stages from one other. CASIAN Stages were significantly associated with treatment modality and primary diagnosis, and CASIAN Stage at Time 1 was significantly associated with Stage at 6 month follow-up. Conclusions: Provisional support is provided for a staging model in AN. Larger studies with longer follow-up of cases are now needed to replicate and extend these findings and evaluate the overall utility of staging as well as optimal staging models

    Evidence for the role of EPHX2 gene variants in anorexia nervosa.

    Get PDF
    Anorexia nervosa (AN) and related eating disorders are complex, multifactorial neuropsychiatric conditions with likely rare and common genetic and environmental determinants. To identify genetic variants associated with AN, we pursued a series of sequencing and genotyping studies focusing on the coding regions and upstream sequence of 152 candidate genes in a total of 1205 AN cases and 1948 controls. We identified individual variant associations in the Estrogen Receptor-ß (ESR2) gene, as well as a set of rare and common variants in the Epoxide Hydrolase 2 (EPHX2) gene, in an initial sequencing study of 261 early-onset severe AN cases and 73 controls (P=0.0004). The association of EPHX2 variants was further delineated in: (1) a pooling-based replication study involving an additional 500 AN patients and 500 controls (replication set P=0.00000016); (2) single-locus studies in a cohort of 386 previously genotyped broadly defined AN cases and 295 female population controls from the Bogalusa Heart Study (BHS) and a cohort of 58 individuals with self-reported eating disturbances and 851 controls (combined smallest single locus P<0.01). As EPHX2 is known to influence cholesterol metabolism, and AN is often associated with elevated cholesterol levels, we also investigated the association of EPHX2 variants and longitudinal body mass index (BMI) and cholesterol in BHS female and male subjects (N=229) and found evidence for a modifying effect of a subset of variants on the relationship between cholesterol and BMI (P<0.01). These findings suggest a novel association of gene variants within EPHX2 to susceptibility to AN and provide a foundation for future study of this important yet poorly understood condition
    • 

    corecore