117 research outputs found
Concentrated Differential Privacy: Simplifications, Extensions, and Lower Bounds
"Concentrated differential privacy" was recently introduced by Dwork and
Rothblum as a relaxation of differential privacy, which permits sharper
analyses of many privacy-preserving computations. We present an alternative
formulation of the concept of concentrated differential privacy in terms of the
Renyi divergence between the distributions obtained by running an algorithm on
neighboring inputs. With this reformulation in hand, we prove sharper
quantitative results, establish lower bounds, and raise a few new questions. We
also unify this approach with approximate differential privacy by giving an
appropriate definition of "approximate concentrated differential privacy.
Integration of data from remote monitoring systems and programmers into the hospital electronic health record system based on international standards
Remote follow-up of implanted ICDs may offer a solution to the problem of overcrowded outpatient clinics. All major device companies have developed a remote follow-up solution. Data obtained from the remote follow-up systems are stored in a central database system, operated and owned by the device company and accessible for the physician or technician. However, the problem now arises that part of the patientās clinical information is stored in the local electronic health record (EHR) system in the hospital, while another part is only available in the remote monitoring database. This may potentially result in patient safety issues. Ideally all information should become available in the EHR system. IHE (Integrating the Healthcare Enterprise) is an initiative to improve the way computer systems in healthcare share information. To address the requirement of integrating remote monitoring data in the local EHR, the IHE Implantable Device Cardiac Observation (IDCO) profile has been developed. In our hospital, we have implemented the IHE IDCO profile to import data from the remote databases from two device vendors into the departmental Cardiology Information System. Data are exchanged via an HL7/XML communication protocol, as defined in the IHE IDCO profile
Prognostic Importance of Atrial Fibrillation in Implantable Cardioverter-Defibrillator Patients
ObjectivesThis study aimed to assess the prevalence of different types of atrial fibrillation (AF) and their prognostic importance in implantable cardioverter-defibrillator (ICD) patients.BackgroundThe prevalence of AF has taken epidemic proportions in the population with cardiovascular disease. The prognostic importance of different types of AF in ICD patients remains unclear.MethodsData on 913 consecutive patients (79% men, mean age 62 Ā± 13 years) receiving an ICD at the Leiden University Medical Center were prospectively collected. Among other characteristics, the existence and type of AF (paroxysmal, persistent, or permanent) were assessed at implantation. During follow-up, the occurrence of appropriate or inappropriate device therapy as well as mortality was noted.ResultsAt implantation, 73% of patients had no history of AF, 9% had a history of paroxysmal AF, 7% had a history of persistent AF, and 11% had permanent AF. During 833 Ā± 394 days of follow-up, 117 (13%) patients died, 228 (25%) patients experienced appropriate device discharge, and 139 (15%) patients received inappropriate shocks. Patients with permanent AF exhibited more than double the risk of mortality, ventricular arrhythmias triggering device discharge, and inappropriate device therapy. Patients with paroxysmal or persistent AF did not show a significant increased risk of mortality or appropriate device therapy but demonstrated almost 3 times the risk of inappropriate device therapy.ConclusionsIn the population currently receiving ICD treatment outside the setting of clinical trials, a large portion has either a history of AF or permanent AF. Both types of AF have prognostic implications for mortality and appropriate as well as inappropriate device discharge
Highly crystallized as-grown smooth and superconducting MgB2 films by molecular-beam epitaxy
We have investigated the growth of superconductive thin films of magnesium diboride (MgB2) by molecular-beam epitaxy. A Si(111) substrate with a seed layer of MgO was used for the growth of these films by varying parameters such as the growth temperature, Mg:B flux ratio and deposition rate as well as the background pressure. It was found that highly crystallized films could already form at 250 Ā°C; however, only in a narrow window of growth parameters. The highest critical temperature of 35.2 K with a sharp transition (TC of 0.5 K) was observed for films grown at 300 Ā°C. Using a capping layer of MgO proved to be highly beneficial for the preservation and the smoothness of these films. Together with the fact that MgO proved to be a good seed layer for thin films of MgB2 makes it an ideal candidate for growing all epitaxial MgB2 Josephson junctions. Ā©2002 American Institute of Physics
Trends in adoption of extravascular cardiac implantable electronic devices:the Dutch cohort
Introduction: Conventional implantable cardioverter-defibrillators (ICDs) and pacemakers carry aĀ risk of pocket- and lead-related complications in particular. To avoid these complications, extravascular devices (EVDs) have been developed, such as the subcutaneous ICD (S-ICD) and leadless pacemaker (LP). However, data on patient or centre characteristics related to the actual adoption of EVDs are lacking. Objective: To assess real-world nationwide trends in EVD adoption in the Netherlands. Methods: Using the Netherlands Heart Registration, all consecutive patients with aĀ de novo SāICD or conventional single-chamber ICD implantation between 2012ā2020, or de novo LP or conventional single-chamber pacemaker implantation between 2014ā2020 were included. Trends in adoption are described for various patient and centre characteristics. Result: From 2012ā2020, 2190 SāICDs and 10,683 conventional ICDs were implanted; from 2014ā2020, 712 LPs and 11,103 conventional pacemakers were implanted. The general use has increased (S-ICDs 8 to 21%; LPs 1 to 8%), but this increase seems to have reached aĀ plateau. SāICD recipients were younger than conventional ICD recipients (pāÆ< 0.001) and more often female (pāÆ< 0.001); LP recipients were younger than conventional pacemaker recipients (pāÆ< 0.001) and more often male (pāÆ= 0.03). Both SāICDs and LPs were mainly implanted in high-volume centres with cardiothoracic surgery on-site, although over time SāICDs were increasingly implanted in centres without cardiothoracic surgery (pāÆ< 0.001). Conclusion: This nationwide study demonstrated aĀ relatively quick adoption of innovative EVDs with aĀ plateau after approximately 4Ā years. SāICD use is especially high in younger patients. EVDs are mainly implanted in high-volume centres with cardiothoracic surgery back-up, but SāICD use is expanding beyond those centres.</p
Fertility preservation in female classic galactosemia patients
Almost every female classic galactosemia patient develops primary ovarian insufficiency (POI) as a diet-independent complication of the disease. This is a major concern for patients and their parents, and physicians are often asked about possible options to preserve fertility. Unfortunately, there are no recommendations on fertility preservation in this group. The unique pathophysiology of classic galactosemia with a severely reduced follicle pool at an early age requires an adjusted approach. In this article recommendations for physicians based on current knowledge concerning galactosemia and fertility preservation are made. Fertility preservation is only likely to be successful in very young prepubertal patients. In this group, cryopreservation of ovarian tissue is currently the only available technique. However, this technique is not ready for clinical application, it is considered experimental and reduces the ovarian reserve. Fertility preservation at an early age also raises ethical questions that should be taken into account. In addition, spontaneous conception despite POI is well described in classic galactosemia. The uncertainty surrounding fertility preservation and the significant chance of spontaneous pregnancy warrant counseling towards conservative application of these techniques. We propose that fertility preservation should only be offered with appropriate institutional research ethics approval to classic galactosemia girls at a young prepubertal age
Impaired fertility and motor function in a zebrafish model for classic galactosemia
Classic galactosemia is a genetic disorder of galactose metabolism, caused by severe deficiency of galactose-1-phosphate uridylyltransferase (GALT) enzyme activity due to mutations of the GALT gene. Its pathogenesis is still not fully elucidated, and a therapy that prevents chronic impairments is lacking. In order to move research forward, there is a high need for a novel animal model, which allows organ studies throughout development and high-throughput screening of pharmacologic compounds. Here, we describe the generation of a galt knockout zebrafish model and present its phenotypical characterization. Using a TALEN approach, a galt knockout line was successfully created. Accordingly, biochemical assays confirm essentially undetectable galt enzyme activity in homozygotes. Analogous to humans, galt knockout fish accumulate galactose-1-phosphate upon exposure to exogenous galactose. Furthermore, without prior exposure to exogenous galactose, they exhibit reduced motor activity and impaired fertility (lower egg quantity per mating, higher number of unsuccessful crossings), resembling the human phenotype(s) of neurological sequelae and subfertility. In conclusion, our galt knockout zebrafish model for classic galactosemia mimics the human phenotype(s) at biochemical and clinical levels. Future studies in our model will contribute to improved understanding and management of this disorder. Electronic supplementary material The online version of this article (doi:10.1007/s10545-017-0071-1) contains supplementary material, which is available to authorized users
Five-year safety and efficacy of leadless pacemakers in a Dutch cohort
BACKGROUND: Adequate real-world safety and efficacy of leadless pacemakers (LPs) have been demonstrated up to 3 years after implantation. Longer-term data are warranted to assess the net clinical benefit of leadless pacing.OBJECTIVE: The purpose of this study was to evaluate the long-term safety and efficacy of LP therapy in a real-world cohort.METHODS: In this retrospective cohort study, all consecutive patients with a first LP implantation from December 21, 2012, to December 13, 2016, in 6 Dutch high-volume centers were included. The primary safety endpoint was the rate of major procedure- or device-related complications (ie, requiring surgery) at 5-year follow-up. Analyses were performed with and without Nanostim battery advisory-related complications. The primary efficacy endpoint was the percentage of patients with a pacing capture threshold ā¤2.0 V at implantation and without ā„1.5-V increase at the last follow-up visit.RESULTS: A total of 179 patients were included (mean age 79 Ā± 9 years), 93 (52%) with a Nanostim and 86 (48%) with a Micra VR LP. Mean follow-up duration was 44 Ā± 26 months. Forty-one major complications occurred, of which 7 were not advisory related. The 5-year major complication rate was 4% without advisory-related complications and 27% including advisory-related complications. No advisory-related major complications occurred a median 10 days (range 0-88 days) postimplantation. The pacing capture threshold was low in 163 of 167 patients (98%) and stable in 157 of 160 (98%).CONCLUSION: The long-term major complication rate without advisory-related complications was low with LPs. No complications occurred after the acute phase and no infections occurred, which may be a specific benefit of LPs. The performance was adequate with a stable pacing capture threshold.</p
āSell[ing] what hasnāt got a nameā: An exploration of the different understandings and definitions of ācommunity engagementā work in the performing arts
Widely known to promote broader involvement in the processes which define the arts and culture (Webster, 1997), community engagement work in the performing arts ā despite employing a set of commonly recognised norms ā has tended to be conceptualised differently both historically and contemporarily. Drawing on ethnographic research ā particularly semi-structured qualitative interview accounts of numerous British practitioners with a track record of work in the sector, the article explores these different conceptualisations. The article finds that it is the actual āwork that mattersā and not what it is named, and that the diversity of understandings and definitions among sectoral practitioners is reflective of evolving thinking, values and practice, something that may be destabilising for better or worse
Forward K+ production in subthreshold pA collisions at 1.0 GeV
K+ meson production in pA (A = C, Cu, Au) collisions has been studied using
the ANKE spectrometer at an internal target position of the COSY-Juelich
accelerator. The complete momentum spectrum of kaons emitted at forward angles,
theta < 12 degrees, has been measured for a beam energy of T(p)=1.0 GeV, far
below the free NN threshold of 1.58 GeV. The spectrum does not follow a thermal
distribution at low kaon momenta and the larger momenta reflect a high degree
of collectivity in the target nucleus.Comment: 4 pages, 3 figure
- ā¦