15 research outputs found

    Technology aerial application of fungicides in irrigated rice

    No full text
    This study aimed to evaluate the effect of equipment and application rates, for the control of foliar diseases and pathogens of grains of rice cultivar Puitá CL Inta, with the fungicide azoxystrobin + difenoconazole, and check the density and penetration of drops in the canopy of plants with water sensitive papers. We evaluated the amount of fungicide deposited in the canopy by chromatographic analysis and determined the relationship between the leaf area and the weight of upper and lower layers of the plants. The products were sprayed with Stol deflector nozzle, Travicar hydraulic nozzle and rotative atomizer Turboaero, with volumes between 10 and 30 L.ha-1 . The use of water sensitive papers allowed to verify that higher application rates provided a higher density of droplets in the upper stratum of the canopy of leaves and that all equipment, as well as application rates similar to promote penetration of droplets into the canopy. It follows that to study the distribution of chemicals in the lower and upper layers of the plants via chromatography, can be made with the extraction of plant leaf area portions and not by amounts equivalent weight equal. Even with low disease severity, fungicide application was shown to be important in controlling fungi present in grain post-harvest, such as Fusarium sp. and Gerlachia sp., and the pathogens Bipolaris sp. and Gerlachia sp. at field conditions.Conselho Nacional de Pesquisa e Desenvolvimento Científico e Tecnológico - CNPqEste trabalho teve por objetivo avaliar o efeito de equipamentos e taxas de aplicação, via aérea, no controle de doenças foliares e patógenos de grãos do arroz irrigado da cultivar Puitá Inta CL, com o fungicida Azoxistrobina 250g + Difenoconazol 250, além de verificar a densidade e penetração de gotas no dossel das plantas através de cartões hidrosensíveis. Avaliou-se a quantidade de fungicida depositado nos estratos superior e inferior através de análise cromatográfica e determinou-se a relação entre a área foliar e o peso dos estratos inferior e superior das plantas. As pulverizações foram realizadas com bico defletor Stol, bico hidráulico Travicar e atomizador rotativo de discos Turboaero, com volumes variando entre 10 e 30 L.ha-1 . A utilização de cartões hidronsensiveis possibilitou verificar que taxas de aplicação maiores proporcionaram maior densidade de gotas no estrato superior do dossel foliar e que todos os equipamentos, assim como as taxas de aplicação promovem similar penetração de gotas no dossel. Conclui-se que para estudar a distribuição de produtos químicos nos estratos inferior e superior das plantas via cromatografia, devem ser feitas extrações de porções vegetais com área foliar equivalente e não por quantidades com pesos iguais. Mesmo com pouca severidade de doença, a aplicação de fungicida mostrou-se importante no controle de fungos presentes nos grãos em pós-colheita, a exemplo de Fusarium sp. e Gerlachia sp.e dos patógenos Bipolaris sp. e Gerlachia sp. em condições de campo

    Ocorrência de Phakopsora euvitis Ono em Santa Maria, Rio Grande do Sul

    No full text
    Na safra 2004/05, a ferrugem da videira foi identificada pela primeira vez em parreirais localizados em Santa Maria/RS. No Brasil, a doença já havia sido identificada em Jandaia do Sul-Paraná (2001), em São Paulo e em Mato Grosso do Sul (2000). A doença é causada pelo fungo Phakopsora euvitis, geralmente disseminado pelo vento e favorecido por condições de umidade elevadas. Em condição ambiente favorável, é possível que o patógeno ataque o hospedeiro intermediário na região ou migre anualmente de áreas atacadas

    Aplicação aérea de fungicidas com diferentes equipamentos e volumes sobre a produtividade, qualidade de grãos e controle de doenças em arroz irrigado

    No full text
    Os tratamentos fitossanitários na cultura do arroz irrigado geralmente são realizados via aplicação aérea. Por isso, o trabalho objetivou avaliar a produtividade, qualidade do grão e incidência de doenças em arroz da cultivar 'Puitá Inta CL' através da aplicação dos fungicidas Azoxistrobina e Difenoconazol com bicos defletores, 20 e 30L ha-1, bicos cônicos 20 e 30L ha-1 e atomizadores rotativos de disco 10 e 15L ha-1. Os tratamentos realizados com atomizador rotativo de disco 10L ha-1 e bico cônico 30L ha-1, receberam uma segunda aplicação 15 dias após. Os parâmetros avaliados foram os níveis de doenças foliares, peso de mil grãos, número de grãos por panícula, patologia de sementes, renda e rendimento. Não se verificou nenhuma diferença entre os tratamentos em nível de campo, entretanto, as avaliações pós-colheita revelaram importante controle dos fungos Fusarium sp., Gerlachia sp. e Bipolaris sp

    Systems and rates of aerial application of fungicides in irrigated rice

    No full text
    ABSTRACT The present research studied the performance of flat-fan and hollow-cone nozzles, with application rates of 20 and 30 L ha-1, and rotary disc atomizer with application rates of 10 and 15 L ha-1. The test was conducted with a fungicide spray tank composed of Azoxystrobin + Difenoconazole, in which the density and penetration of droplets into the canopy were evaluated using a water-sensitive paper and the distribution of the active ingredients in the plant was evaluated through the chromatographic analysis. Higher application rates resulted in higher droplet density in the upper stratum of plants. In all treatments, the penetration of the droplets was 26% into the middle stratum and 23% into the lower stratum, in relation to the top of the crop, resulting in an average 25% penetration of droplets into the leaf canopy. The active ingredients were distributed in greater quantity in the upper stratum of the plant. For the same weight, the upper part of the ‘Puitá Inta CL’ rice cultivar has a leaf area 6.4 times larger than the lower part. It was concluded that higher application rate leads to higher droplet density in the upper stratum of the leaf canopy and that all systems and application rates promoted similar penetration of droplets into the canopy

    Systems and rates of aerial application of fungicides in irrigated rice

    No full text
    <div><p>ABSTRACT The present research studied the performance of flat-fan and hollow-cone nozzles, with application rates of 20 and 30 L ha-1, and rotary disc atomizer with application rates of 10 and 15 L ha-1. The test was conducted with a fungicide spray tank composed of Azoxystrobin + Difenoconazole, in which the density and penetration of droplets into the canopy were evaluated using a water-sensitive paper and the distribution of the active ingredients in the plant was evaluated through the chromatographic analysis. Higher application rates resulted in higher droplet density in the upper stratum of plants. In all treatments, the penetration of the droplets was 26% into the middle stratum and 23% into the lower stratum, in relation to the top of the crop, resulting in an average 25% penetration of droplets into the leaf canopy. The active ingredients were distributed in greater quantity in the upper stratum of the plant. For the same weight, the upper part of the ‘Puitá Inta CL’ rice cultivar has a leaf area 6.4 times larger than the lower part. It was concluded that higher application rate leads to higher droplet density in the upper stratum of the leaf canopy and that all systems and application rates promoted similar penetration of droplets into the canopy.</p></div

    Aplicação aérea de fungicidas na cultura do arroz irrigado com diferentes bicos de pulverização Aerial fungicide application on irrigated lowland rice with varying spraying nozzles

    No full text
    Na safra agrícola 2007/2008, foi realizado um estudo com o objetivo de avaliar a deposição e penetração de gotas através de cartões hidrossensíveis e análise cromatográfica. Para isso, utilizaram-se o bico eletrostático, bico hidráulico e atomizadores rotativos de discos com diferentes volumes de calda. As pulverizações foram realizadas no estádio R3 da cultura, com aeronave Ipanema EMB-202, aplicando-se fungicida trifloxistrobina + propiconazole. Através da leitura de cartões hidrossensíveis, determinou-se a densidade de gotas, o diâmetro médio numérico, diâmetro médio volumétrico, amplitude relativa e a penetração de gotas no dossel (%). Também foi utilizada a análise cromatográfica para determinar a penetração do produto no alvo biológico. O bico hidráulico, com taxa de aplicação de 20L ha-1 e 30L ha-1, e o bico eletrostático, com taxa de aplicação de 10L ha-1, obtiveram maior densidade de gotas no terço superior. O uso de atomizadores rotativos de disco com volume de calda de 15L ha-1 apresentou maior densidade de gotas no terço médio e inferior. Para diâmetro médio volumétrico, os bicos eletrostáticos juntamente com os atomizadores rotativos de discos apresentaram os menores valores. A maior homogeneidade de gotas no terço superior foi obtida com atomizadores rotativos de disco com taxa de aplicação de 6L ha-1 e 10L ha-¹. A análise cromatográfica mostrou que a maior quantidade de produto foi retida com bicos eletrostáticos com taxa de aplicação de 10L ha- ¹ no extrato inferior da planta.In the harvest year of 2007/2008 a study was carried to evaluate the droplets deposition and penetration throughout water sensible cards and gas chromatographic analysis. Were used the hydraulic nozzle, electrostatic nozzle and rotary-disk atomizer spraying systems, with different volumes of spray solution. Aerial applications were performed at R3 stage using the aircraft Ipanema EMB-202 and the fungicide trifloxystrobin + propiconazole. Throughout the lection of the water sensible cards was determinate the droplet density, the medium numeric diameter, the medium volumetric diameter, the relative amplitude and the percentage of droplet penetration in the canopy. Chromatographic analysis was also performed to determinate the fungicide penetration into the biological target. The pulverization systems hydraulic nozzle 20L ha-1 and 30L ha-1 and the electrostatic system 10L ha-1 demonstrated higher droplet density in the upper third. The rotary-disk atomizer 15L ha-1 showed higher droplet density in the mid and low third. To the medium volumetric diameter, the electrostatic nozzles and the rotary-disk atomizer showed the lowest values. The higher homogeneity in the upper third was attained with rotary-disk atomizer at the pulverization rates of 6L ha-1 and 10L ha-1. The chromatographic analysis showed that the higher quantity of product retention was obtained with the electrostatic system at the pulverization rate of 10L ha-1 in the lower plant extract
    corecore