162 research outputs found

    Applying next-generation sequencing platforms for pharmacogenomic testing in clinical practice

    Get PDF
    Pharmacogenomics (PGx) studies the use of genetic data to optimize drug therapy. Numerous clinical centers have commenced implementing pharmacogenetic tests in clinical routines. Next-generation sequencing (NGS) technologies are emerging as a more comprehensive and time- and cost-effective approach in PGx. This review presents the main considerations for applying NGS in guiding drug treatment in clinical practice. It discusses both the advantages and the challenges of implementing NGS-based tests in PGx. Moreover, the limitations of each NGS platform are revealed, and the solutions for setting up and management of these technologies in clinical practice are addressed.Personalised Therapeutic

    Hyperekplexia Phenotype of Glycine Receptor α1 Subunit Mutant Mice Identifies Zn2+ as an Essential Endogenous Modulator of Glycinergic Neurotransmission

    Get PDF
    SummaryZn2+ is thought to modulate neurotransmission by affecting currents mediated by ligand-gated ion channels and transmitter reuptake by Na+-dependent transporter systems. Here, we examined the in vivo relevance of Zn2+ neuromodulation by producing knockin mice carrying the mutation D80A in the glycine receptor (GlyR) α1 subunit gene (Glra1). This substitution selectively eliminates the potentiating effect of Zn2+ on GlyR currents. Mice homozygous for Glra1(D80A) develop a severe neuromotor phenotype postnatally that resembles forms of human hyperekplexia (startle disease) caused by mutations in GlyR genes. In spinal neurons and brainstem slices from Glra1(D80A) mice, GlyR expression, synaptic localization, and basal glycinergic transmission were normal; however, potentiation of spontaneous glycinergic currents by Zn2+ was significantly impaired. Thus, the hyperekplexia phenotype of Glra1(D80A) mice is due to the loss of Zn2+ potentiation of α1 subunit containing GlyRs, indicating that synaptic Zn2+ is essential for proper in vivo functioning of glycinergic neurotransmission

    Interobserver reliability in musculoskeletal ultrasonography: Results from a "Teach the Teachers" rheumatologist course

    Get PDF
    Objective: To assess the interobserver reliability of the main periarticular and intra-articular ultrasonographic pathologies and to establish the principal disagreements on scanning technique and diagnostic criteria between a group of experts in musculoskeletal ultrasonography. Methods: The shoulder, wrist/hand, ankle/foot, or knee of 24 patients with rheumatic diseases were evaluated by 23 musculoskeletal ultrasound experts from different European countries randomly assigned to six groups. The participants did not reach consensus on scanning method or diagnostic criteria before the investigation. They were unaware of the patients' clinical and imaging data. The experts from each group undertook a blinded ultrasound examination of the four anatomical regions. The ultrasound investigation included the presence/absence of joint effusion/synovitis, bony cortex abnormalities, tenosynovitis, tendon lesions, bursitis, and power Doppler signal. Afterwards they compared the ultrasound findings and re-examined the patients together while discussing their results. Results: Overall agreements were 91% for joint effusion/synovitis and tendon lesions, 87% for cortical abnormalities, 84% for tenosynovitis, 83.5% for bursitis, and 83% for power Doppler signal; κ values were good for the wrist/hand and knee (0.61 and 0.60) and fair for the shoulder and ankle/foot (0.50 and 0.54). The principal differences in scanning method and diagnostic criteria between experts were related to dynamic examination, definition of tendon lesions, and pathological v physiological fluid within joints, tendon sheaths, and bursae. Conclusions: Musculoskeletal ultrasound has a moderate to good interobserver reliability. Further consensus on standardisation of scanning technique and diagnostic criteria is necessary to improve musculoskeletal ultrasonography reproducibility

    Feasibility of pharmacy-initiated pharmacogenetic screening for CYP2D6 and CYP2C19

    Get PDF
    PURPOSE: Our purpose was to investigate the feasibility of pharmacy-initiated pharmacogenetic (PGt) screening in primary care with respect to patient willingness to participate, quality of DNA collection with saliva kits, genotyping, and dispensing data retrieved from the pharmacy. METHODS: Polypharmacy patients aged >60 years who used at least one drug with Anatomical Therapeutic Chemical (ATC) code N06AA01-N06AX19 (antidepressants), A02BC01-A02BC05 (proton-pump inhibitors), N05AA01-N05AH04 (antipsychotics), or C07AB02 (metoprolol) in the preceding 2 years were randomly selected. DNA was collected with saliva kits and genotyped for CYP2D6 and CYP2C19 with the AmpliChip. Pharmacy dispensing records were retrieved and screened for drugs interacting with the patient's CYP2D6 and CYP2C19 genotype by using the evidence-based PGt guidelines from the Dutch Pharmacogenetics Working Group. RESULTS: Out of the 93 invited patients, 54 (58.1%) provided informed consent. Nine saliva samples (16.7%) contained too little DNA. Call rates for CYP2D6 and CYP2C19 were 93.3% and 100%, respectively. Frequencies of genotype-predicted phenotype were 2.4%, 38.1%, 54.8%, and 4.8% for CYP2D6 poor metabolizers (PM), intermediate metabolizers (IM), extensive metabolizers (EM), and ultrarapid metabolizers (UM) respectively. For CYP2C19 genotype-predicted phenotype, frequencies were 2.2%, 15.6%, and 82.2% for PM, IM, and EM, respectively. CONCLUSIONS: This study shows that pharmacy-initiated PGt screening is feasible for a primary care setting

    How does a cadaver model work for testing ultrasound diagnostic capability for rheumatic-like tendon damage?

    Get PDF
    To establish whether a cadaver model can serve as an effective surrogate for the detection of tendon damage characteristic of rheumatoid arthritis (RA). In addition, we evaluated intraobserver and interobserver agreement in the grading of RA-like tendon tears shown by US, as well as the concordance between the US findings and the surgically induced lesions in the cadaver model. RA-like tendon damage was surgically induced in the tibialis anterior tendon (TAT) and tibialis posterior tendon (TPT) of ten ankle/foot fresh-frozen cadaveric specimens. Of the 20 tendons examined, six were randomly assigned a surgically induced partial tear; six a complete tear; and eight left undamaged. Three rheumatologists, experts in musculoskeletal US, assessed from 1 to 5 the quality of US imaging of the cadaveric models on a Likert scale. Tendons were then categorized as having either no damage, (0); partial tear, (1); or complete tear (2). All 20 tendons were blindly and independently evaluated twice, over two rounds, by each of the three observers. Overall, technical performance was satisfactory for all items in the two rounds (all values over 2.9 in a Likert scale 1-5). Intraobserver and interobserver agreement for US grading of tendon damage was good (mean κ values 0.62 and 0.71, respectively), with greater reliability found in the TAT than the TPT. Concordance between US findings and experimental tendon lesions was acceptable (70-100 %), again greater for the TAT than for the TPT. A cadaver model with surgically created tendon damage can be useful in evaluating US metric properties of RA tendon lesions

    Interobserver reliability in musculoskeletal ultrasonography: Results from a "Teach the Teachers" rheumatologist course

    Get PDF
    Objective: To assess the interobserver reliability of the main periarticular and intra-articular ultrasonographic pathologies and to establish the principal disagreements on scanning technique and diagnostic criteria between a group of experts in musculoskeletal ultrasonography. Methods: The shoulder, wrist/hand, ankle/foot, or knee of 24 patients with rheumatic diseases were evaluated by 23 musculoskeletal ultrasound experts from different European countries randomly assigned to six groups. The participants did not reach consensus on scanning method or diagnostic criteria before the investigation. They were unaware of the patients' clinical and imaging data. The experts from each group undertook a blinded ultrasound examination of the four anatomical regions. The ultrasound investigation included the presence/absence of joint effusion/synovitis, bony cortex abnormalities, tenosynovitis, tendon lesions, bursitis, and power Doppler signal. Afterwards they compared the ultrasound findings and re-examined the patients together while discussing their results. Results: Overall agreements were 91% for joint effusion/synovitis and tendon lesions, 87% for cortical abnormalities, 84% for tenosynovitis, 83.5% for bursitis, and 83% for power Doppler signal; \u3ba values were good for the wrist/hand and knee (0.61 and 0.60) and fair for the shoulder and ankle/foot (0.50 and 0.54). The principal differences in scanning method and diagnostic criteria between experts were related to dynamic examination, definition of tendon lesions, and pathological v physiological fluid within joints, tendon sheaths, and bursae. Conclusions: Musculoskeletal ultrasound has a moderate to good interobserver reliability. Further consensus on standardisation of scanning technique and diagnostic criteria is necessary to improve musculoskeletal ultrasonography reproducibility

    Interobserver reliability in musculoskeletal ultrasonography: Results from a "Teach the Teachers" rheumatologist course

    Get PDF
    Objective: To assess the interobserver reliability of the main periarticular and intra-articular ultrasonographic pathologies and to establish the principal disagreements on scanning technique and diagnostic criteria between a group of experts in musculoskeletal ultrasonography. Methods: The shoulder, wrist/hand, ankle/foot, or knee of 24 patients with rheumatic diseases were evaluated by 23 musculoskeletal ultrasound experts from different European countries randomly assigned to six groups. The participants did not reach consensus on scanning method or diagnostic criteria before the investigation. They were unaware of the patients' clinical and imaging data. The experts from each group undertook a blinded ultrasound examination of the four anatomical regions. The ultrasound investigation included the presence/absence of joint effusion/synovitis, bony cortex abnormalities, tenosynovitis, tendon lesions, bursitis, and power Doppler signal. Afterwards they compared the ultrasound findings and re-examined the patients together while discussing their results. Results: Overall agreements were 91% for joint effusion/synovitis and tendon lesions, 87% for cortical abnormalities, 84% for tenosynovitis, 83.5% for bursitis, and 83% for power Doppler signal; κ values were good for the wrist/hand and knee (0.61 and 0.60) and fair for the shoulder and ankle/foot (0.50 and 0.54). The principal differences in scanning method and diagnostic criteria between experts were related to dynamic examination, definition of tendon lesions, and pathological v physiological fluid within joints, tendon sheaths, and bursae. Conclusions: Musculoskeletal ultrasound has a moderate to good interobserver reliability. Further consensus on standardisation of scanning technique and diagnostic criteria is necessary to improve musculoskeletal ultrasonography reproducibility

    Reliability testing of tendon disease using two different scanning methods in patients with rheumatoid arthritis

    Get PDF
    Objective. To assess the intra- and interobserver reliability of musculoskeletal ultrasonography (US) in detecting inflammatory and destructive tendon abnormalities in patients with RA using two different scanning methods.Methods. Thirteen observers examined nine patients with RA and one healthy individual in two rounds independently and blindly of each other. Each round consisted of two consecutive examinations, an anatomy-based examination and a free examination according to personal preferences. The following tendons were evaluated: wrist extensor compartments 2, 4 and 6, finger flexor tendons 3 and 4 at MCP level, tibialis posterior tendon and both peronei tendons. Overall, positive and negative agreements and κ-values for greyscale (GS) tenosynovitis, peritendinous power Doppler (PPD) signal, intratendinous power Doppler (IPD) signal and GS tendon damage were calculated.Results. Intraobserver κ-value ranges were 0.53-0.55 (P < 0.0005) for GS tenosynovitis, 0.61-0.64 (P < 0.0005) for PPD signal, 0.65-0.66 (P < 0.0005) for IPD signal and 0.44-0.53 (P < 0.0005) for GS tendon damage. For interobserver reliability, substantial overall agreement ranged from 80 to 89% for GS tenosynovitis, 97 to 100% for PPD signal, 97 to 100% for IPD signal and 97 to 100% for GS tendon damage. Results were independent of scanning technique.Conclusion. Intraobserver reliability for tenosynovitis and tendon damage varied from moderate for GS to good for PD. Overall interobserver reliability for tenosynovitis and tendon damage was excellent both for GS and PD. This qualitative scoring system may serve as the first step to a semi-quantitative score for tendon pathology. © The Author 2012. Published by Oxford University Press on behalf of the British Society for Rheumatology. All rights reserved

    Self-directed learning of basic musculoskeletal ultrasound among rheumatologists in the United States

    Get PDF
    Objective Because musculoskeletal ultrasound (MSUS) is highly user dependent, we aimed to establish whether non-mentored learning of MSUS is sufficient to achieve the same level of diagnostic accuracy and scanning reliability as has been achieved by rheumatologists recognized as international experts in MSUS. Methods A group of 8 rheumatologists with more experience in MSUS and 8 rheumatologists with less experience in MSUS participated in an MSUS exercise to assess patients with musculoskeletal abnormalities commonly seen in a rheumatology practice. Patients' established diagnoses were obtained from chart review (gout, osteoarthritis, rotator cuff syndrome, rheumatoid arthritis, and seronegative arthritis). Two examining groups were formed, each composed of 4 less experienced and 4 more experienced examiners. Each group scanned 1 predefined body region (hand, wrist, elbow, shoulder, knee, or ankle) in each of 8 patients, blinded to medical history and physical examination. Structural abnormalities were noted with dichotomous answers, and an open-ended answer was used for the final diagnosis. Results Less experienced and more experienced examiners achieved the same diagnostic accuracy (US-established diagnosis versus chart review diagnosis). The interrater reliability for tissue pathology was slightly higher for more experienced versus less experienced examiners (Κ = 0.43 versus Κ = 0.34; P = 0.001). Conclusion Non-mentored training in MSUS can lead to the achievement of diagnostic accuracy in MSUS comparable to that achieved by highly experienced international experts. Reliability may increase slightly with additional experience. Further study is needed to determine the minimal training requirement to achieve proficiency in MSUS.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/65036/1/20063_ftp.pd

    A Method to Exchange Recombinant Differentially Phosphorylated Rhodamine-Labeled Cardiac RLC into Permeabilized Cardiac Trabeculae

    Get PDF
    Cyclosporine, everolimus, and tacrolimus are the cornerstone of immunosuppressive therapy in renal transplantation. These drugs are characterized by narrow therapeutic windows, highly variable pharmacokinetics (PK), and metabolism by CYP3A enzymes. Recently, the decreased activity allele, CYP3A4*22, was described as a potential predictive marker for CYP3A4 activity. This study investigated the effect of CYP3A4*22, CYP3A5*3, and CYP3A combined genotypes on cyclosporine, everolimus, and tacrolimus PK in renal transplant patients. CYP3A4*22 carriers showed a significant lower clearance for cyclosporine (−15%), and a trend was observed for everolimus (−7%) and tacrolimus (−16%). Patients carrying at least one CYP3A5*1 allele had 1.5-fold higher tacrolimus clearance compared with noncarriers; however, CYP3A5*3 appeared to be nonpredictive for everolimus and cyclosporine. CYP3A combined genotype did not significantly improve prediction of clearance compared with CYP3A5*3 or CYP3A4*22 alone. These data suggest that dose individualization of cyclosporine, everolimus, or tacrolimus therapy based on CYP3A4*22 is not indicated
    • …
    corecore