4 research outputs found

    Mechanical assessment of two hybrid plate designs for pancarpal canine arthrodesis under cyclic loading

    Get PDF
    Pancarpal canine arthrodesis (PCA) sets immobilization of all three carpal joints via dorsal plating to result in bony fusion. Whereas the first version of the plate uses a round hole (RH) for the radiocarpal (RC) screw region, its modification into an oval hole (OH) in a later version improves versatility in surgical application. The aim of this study was to mechanically investigate the fatigue life of the PCA plate types implementing these two features–PCA-RH and PCA-OH. Ten PCA-RH and 20 PCA-OH stainless steel (316LVM) plates were assigned to three study groups (n = 10). All plates were pre-bent at 20° and fixed to a canine forelimb model with simulated radius, RC bone and third metacarpal bone. The OH plates were fixed with an RC screw inserted either most proximal (OH-P) or most distal (OH-D). All specimens were cyclically tested at 8 Hz under 320 N loading until failure. Fatigue life outcome measures were cycles to failure and failure mode. Cycles to failure were higher for RH plate fixation (695,264 ± 344,023) versus both OH-P (447,900 ± 176,208) and OH-D (391,822 ± 165,116) plate configurations, being significantly different between RH and OH-D, p = 0.03. No significant difference was detected between OH-P and OH-D configurations, p = 0.09. Despite potential surgical advantages, the shorter fatigue life of the PCA-OH plate design may mitigate its benefits compared to the plate design with a round radiocarpal screw hole. Moreover, the failure risk of plates with an oval hole is increased regardless from the screw position in this hole. Based on these findings, the PCA plate with the current oval radiocarpal screw hole configuration cannot be recommended for clinical use

    Local bone quality measure and construct failure prediction: a biomechanical study on distal femur fractures

    No full text
    Gehweiler D, Styger U, Gueorguiev B, Colcuc C, Vordemvenne T, Wähnert D. Local bone quality measure and construct failure prediction: a biomechanical study on distal femur fractures. Archives of Orthopaedic and Trauma Surgery. 2022;142(6):1055-1061.Introduction The aim of this investigation was to better understand the differences in local bone quality at the distal femur and their correlation with biomechanical construct failure, with the intention to identify regions of importance to optimize implant anchorage. Materials and methods Seven fresh–frozen female femurs underwent high-resolution peripheral quantitative computed tomography (HR-pQCT) to determine bone mineral density (BMD) within three different regions of interest (distal, intermedium, and proximal) at the distal femur. In addition, local bone quality was assessed by measuring the peak torque necessary to break out the trabecular bone along each separate hole of a locking compression plate (LCP) during its instrumentation. Finally, biomechanical testing was performed using cyclic axial loading until failure in an AO/OTA 33 A3 fracture model. Results Local BMD was highest in the distal region. This was confirmed by the measurement of local bone quality using DensiProbe™. The most distal holes represented locations with the highest breakaway torque resistance, with the holes on the posterior side of the plate indicating higher values than those on its anterior side. We demonstrated strong correlation between the cycles to failure and local bone strength (measured with DensiProbe™) in the most distal posterior screw hole, having the highest peak torque. Conclusion The local bone quality at the distal femur indicates that in plated distal femur fractures the distal posterior screw holes seem to be the key ones and should be occupied. Measurement of the local bone strength with DensiProbe™ is one possibility to determine the risk of construct failure, therefore, thresholds need to be defined

    Titanium Wear Particles Exacerbate S. epidermidis-Induced Implant-Related Osteolysis and Decrease Efficacy of Antibiotic Therapy

    No full text
    Total joint arthroplasty (TJA) surgeries are common orthopedic procedures, but bacterial infection remains a concern. The aim of this study was to assess interactions between wear particles (WPs) and immune cells in vitro and to investigate if WPs affect the severity, or response to antibiotic therapy, of a Staphylococcus epidermidis orthopedic device-related infection (ODRI) in a rodent model. Biofilms grown on WPs were challenged with rifampin and cefazolin (100 µg/mL) to determine antibiotic efficacy. Neutrophils or peripheral blood mononuclear cells (PBMCs) were incubated with or without S. epidermidis and WPs, and myeloperoxidase (MPO) and cytokine release were analyzed, respectively. In the ODRI rodent model, rats (n = 36) had a sterile or S. epidermidis-inoculated screw implanted in the presence or absence of WPs, and a subgroup was treated with antibiotics. Bone changes were monitored using microCT scanning. The presence of WPs decreased antibiotic efficacy against biofilm-resident bacteria and promoted MPO and pro-inflammatory cytokine production in vitro. WPs exacerbated osteolytic responses to S. epidermidis infection and markedly reduced antibiotic efficacy in vivo. Overall, this work shows that the presence of titanium WPs reduces antibiotic efficacy in vitro and in vivo, induces proinflammatory cytokine release, and exacerbates S. epidermidis-induced osteolysis
    corecore