69 research outputs found

    A zinc finger protein array for the visual detection of specific DNA sequences for diagnostic applications.

    Get PDF
    The visual detection of specific double-stranded DNA sequences possesses great potential for the development of diagnostics. Zinc finger domains provide a powerful scaffold for creating custom DNA-binding proteins that recognize specific DNA sequences. We previously demonstrated sequence-enabled reassembly of TEM-1 β-lactamase (SEER-LAC), a system consisting of two inactive fragments of β-lactamase each linked to engineered zinc finger proteins (ZFPs). Here the SEER-LAC system was applied to develop ZFP arrays that function as simple devices to identify bacterial double-stranded DNA sequences. The ZFP arrays provided a quantitative assay with a detection limit of 50 fmol of target DNA. The method could distinguish target DNA from non-target DNA within 5 min. The ZFP arrays provided sufficient sensitivity and high specificity to recognize specific DNA sequences. These results suggest that ZFP arrays have the potential to be developed into a simple and rapid point-of-care (POC) diagnostic for the multiplexed detection of pathogens

    Perinatal Risk Factors for Asthma and Allergic Rhinitis in Children and Adolescents

    Get PDF
    Objectives. In this study, we evaluated the associations between birth-related exposures, postnatal factors, and the risk of allergic rhinitis and asthma in children and adolescents. Methods. We performed a comprehensive search of five literature databases up to May 2023. To quantify the associations of birth-related exposures (birth weight, delivery mode, prematurity, sex, maternal age, and parental allergy history) and postnatal factors (birth order, number of siblings, breastfeeding exclusivity, and breastfeeding duration) with allergic disease, we calculated pooled odds ratios and 95% confidence intervals. We conducted subgroup analyses for allergic disease type, birth order, number of siblings, and parental allergy history. The methodological quality of the identified studies was evaluated using the Newcastle-Ottawa Scale. Results. This meta-analysis included 31 studies, encompassing 218,899 patients in total. The birth-related exposures of low birth weight, maternal age, and prematurity (less than 37 weeks gestation) were not significantly associated with the risk of asthma or allergic rhinitis during childhood or adolescence. Male sex, family history of allergy, and cesarean delivery were linked to an elevated risk of asthma or allergic rhinitis. Among postnatal factors, exclusive breastfeeding, breastfeeding for longer than 6 months, second or later birth order, and having siblings exhibited protective effects against allergic diseases in offspring. Conclusion. The risks of allergic rhinitis and asthma were elevated in male patients, those delivered by cesarean section, and those with a family history of allergy. Conversely, exclusive breastfeeding, breastfeeding for longer than 6 months, and having siblings corresponded to a reduced risk of respiratory allergic diseases

    Nanomedicine: Application Areas and Development Prospects

    Get PDF
    Nanotechnology, along with related concepts such as nanomaterials, nanostructures and nanoparticles, has become a priority area for scientific research and technological development. Nanotechnology, i.e., the creation and utilization of materials and devices at nanometer scale, already has multiple applications in electronics and other fields. However, the greatest expectations are for its application in biotechnology and health, with the direct impact these could have on the quality of health in future societies. The emerging discipline of nanomedicine brings nanotechnology and medicine together in order to develop novel therapies and improve existing treatments. In nanomedicine, atoms and molecules are manipulated to produce nanostructures of the same size as biomolecules for interaction with human cells. This procedure offers a range of new solutions for diagnoses and “smart” treatments by stimulating the body’s own repair mechanisms. It will enhance the early diagnosis and treatment of diseases such as cancer, diabetes, Alzheimer’s, Parkinson’s and cardiovascular diseases. Preventive medicine may then become a reality

    HIV interactions with monocytes and dendritic cells: viral latency and reservoirs

    Get PDF
    HIV is a devastating human pathogen that causes serious immunological diseases in humans around the world. The virus is able to remain latent in an infected host for many years, allowing for the long-term survival of the virus and inevitably prolonging the infection process. The location and mechanisms of HIV latency are under investigation and remain important topics in the study of viral pathogenesis. Given that HIV is a blood-borne pathogen, a number of cell types have been proposed to be the sites of latency, including resting memory CD4+ T cells, peripheral blood monocytes, dendritic cells and macrophages in the lymph nodes, and haematopoietic stem cells in the bone marrow. This review updates the latest advances in the study of HIV interactions with monocytes and dendritic cells, and highlights the potential role of these cells as viral reservoirs and the effects of the HIV-host-cell interactions on viral pathogenesis

    Surgical safety and effectiveness of bilateral axillo-breast approach robotic thyroidectomy: a systematic review and meta-analysis

    No full text
    Objectives: To assess the safety and effectiveness of bilateral axillo-breast approach robotic thyroidectomy in thyroid tumor. Methods: Bilateral axillo-breast approach robotic thyroidectomy and other approaches (open thyroidectomy, transoral robotic thyroidectomy, and bilateral axillo-breast approach endoscopic thyroidectomy) were compared in studies from 6 databases. Results: Twenty-two studies (8830 individuals) were included. Bilateral axillo-breast approach robotic thyroidectomy had longer operation time, greater cosmetic satisfaction, and reduced transient hypoparathyroidism than conventional open thyroidectomy. Compared to bilateral axillo-breast approach endoscopic thyroidectomy, bilateral axillo-breast approach robotic thyroidectomy had greater amount of drainage, lower chances of transient vocal cord palsy and permanent hypothyroidism, and better surgical completeness (postopertive thyroblobulin level and lymph node removal). Bilateral axillo-breast approach robotic thyroidectomy induced greater postoperative drainage and greater patient dissatisfaction than transoral robotic thyroidectomy. Conclusion: Bilateral axillo-breast approach robotic thyroidectomy is inferior to transoral robotic thyroidectomy in drainage and cosmetic satisfaction but superior to bilateral axillo-breast approach endoscopic thyroidectomy in surgical performance. Its operation time is longer, but its cosmetic satisfaction is higher than open thyroidectomy

    Safety and Efficacy of Transoral Robotic Thyroidectomy for Thyroid Tumor: A Systematic Review and Meta-Analysis

    No full text
    Background: To assess the safety and effectiveness of transoral robotic thyroidectomy (TORT) in thyroid tumor. Methods: PubMed, Embase, Web of Science, SCOPUS, Cochrane database, and Google Scholar up to June 2022. Studies comparing outcomes and complications between TORT and control groups (robotic bilateral axillo-breast, trans-axillary, postauricular approach, conventional open thyroidectomy (OT), and transoral endoscopic approach) were analyzed. Results: Ten studies of 1420 individuals. The operative time (SMD 1.15, 95%CI [0.48; 1.89]) was significantly longer and the number of retrieved lymph nodes (LNs) (SMD −0.27, 95%CI [−0.39; −0.16]) was fewer in TORT than in the control group. The postoperative cosmetic satisfaction score (SMD 0.60, 95%CI [0.28; 0.92]) was statistically higher in TORT than in the control group. In subgroup analysis, there was no significant difference between robotic surgeries. However, TORT had significantly longer operative times (SMD 2.08, 95%CI [0.95; 3.20]) and fewer retrieved LNs (SMD −0.32, 95%CI [−0.46; −0.17]) than OT. TORT satisfied significantly more patients in cosmetic view. However, it increased hospitalization days and postoperative pain on the operation day and first day compared to OT. Conclusions: TORT is not inferior to other robotic-assisted approaches. Its operation time and hospitalization days are longer and postoperative pain is greater than OT, although its cosmetic satisfaction is high

    Comparison of Liquid-Based Preparations with Conventional Smears in Thyroid Fine-Needle Aspirates: A Systematic Review and Meta-Analysis

    No full text
    Background: To compare conventional smears (CSs) and liquid-based preparations (LBPs) for diagnosing thyroid malignant or suspicious lesions. Methods: Studies in the PubMed, SCOPUS, Embase, Web of Science, and Cochrane database published up to December 2023. We reviewed 17 studies, including 15,861 samples. Results: The diagnostic odds ratio (DOR) for CS was 23.6674. The area under the summary receiver operating characteristic curve (AUC) was 0.879, with sensitivity, specificity, negative predictive value, and positive predictive value of 0.8266, 0.8668, 0.8969, and 0.7841, respectively. The rate of inadequate specimens was 0.1280. For LBP, the DOR was 25.3587, with an AUC of 0.865. The sensitivity, specificity, negative predictive value, and positive predictive value were 0.8190, 0.8833, 0.8515, and 0.8562. The rate of inadequate specimens was 0.1729. For CS plus LBP, the AUC was 0.813, with a lower DOR of 9.4557 compared to individual methods. Diagnostic accuracy did not significantly differ among CS, LBP, and CS plus LBP. Subgroup analysis was used to compare ThinPrep and SurePath. The DORs were 29.1494 and 19.7734. SurePath had a significantly higher AUC. Conclusions: There was no significant difference in diagnostic accuracy or proportion of inadequate smears between CS and LBP. SurePath demonstrated higher diagnostic accuracy than ThinPrep. Recommendations for fine-needle aspiration cytology should consider cost, feasibility, and accuracy

    Diagnostic Performance of Various Ultrasound Risk Stratification Systems for Benign and Malignant Thyroid Nodules: A Meta-Analysis

    No full text
    Background: To evaluate the diagnostic performance of ultrasound risk-stratification systems for the discrimination of benign and malignant thyroid nodules and to determine the optimal cutoff values of individual risk-stratification systems. Methods: PubMed, Embase, SCOPUS, Web of Science, and Cochrane library databases were searched up to August 2022. Sensitivity and specificity data were collected along with the characteristics of each study related to ultrasound risk stratification systems. Results: Sixty-seven studies involving 76,512 thyroid nodules were included in this research. The sensitivity, specificity, diagnostic odds ratios, and area under the curves by K-TIRADS (4), ACR-TIRADS (TR5), ATA (high suspicion), EU-TIRADS (5), and Kwak-TIRADS (4b) for malignancy risk stratification of thyroid nodules were 92.5%, 63.5%, 69.8%, 70.6%, and 95.8%, respectively; 62.8%, 89.6%, 87.2%, 83.9%, and 63.8%, respectively; 20.7111, 16.8442, 15.7398, 12.2986, and 38.0578, respectively; and 0.792, 0.882, 0.859, 0.843, and 0.929, respectively. Conclusion: All ultrasound-based risk-stratification systems had good diagnostic performance. Although this study determined the best cutoff values in individual risk-stratification systems based on statistical assessment, clinicians could adjust or alter cutoff values based on the clinical purpose of the ultrasound and the reciprocal changes in sensitivity and specificity
    corecore