625 research outputs found

    The Great War 1914-18

    Get PDF

    Multiparameter vision testing apparatus

    Get PDF
    Compact vision testing apparatus is described for testing a large number of physiological characteristics of the eyes and visual system of a human subject. The head of the subject is inserted into a viewing port at one end of a light-tight housing containing various optical assemblies. Visual acuity and other refractive characteristics and ocular muscle balance characteristics of the eyes of the subject are tested by means of a retractable phoroptor assembly carried near the viewing port and a film cassette unit carried in the rearward portion of the housing (the latter selectively providing a variety of different visual targets which are viewed through the optical system of the phoroptor assembly). The visual dark adaptation characteristics and absolute brightness threshold of the subject are tested by means of a projector assembly which selectively projects one or both of a variable intensity fixation target and a variable intensity adaptation test field onto a viewing screen located near the top of the housing

    Fieldwork Effort, Response Rate, and the Distribution of Survey Outcomes: A Multilevel Meta-analysis

    Get PDF
    This study assesses how survey outcome distributions change over repeated calls made to addresses in face-to-face household interview surveys. We consider this question for 541 survey variables, drawn from six major face-to-face UK surveys that have different sample designs, cover different topic areas, and achieve response rates between 54 and 76 percent. Using a multilevel meta-analytic framework, we estimate for each survey variable the expected difference between the point estimate for a proportion at call n and for the full achieved sample. Results show that most variables are surprisingly close to the final achieved sample distribution after only one or two call attempts and before any post-stratification weighting has been applied; the mean expected difference from the final sample proportion across all 559 variables after one call is 1.6 percent, dropping to 0.7 percent after three calls and to 0.4 percent after five calls. These estimates vary only marginally across the six surveys and the different types of questions examined. Our findings add weight to the body of evidence that questions the strength of the relationship between response rate and nonresponse bias. In practical terms, our results suggest that making large numbers of calls at sampled addresses and converting “soft” refusals into interviews are not cost-effective means of minimizing survey error

    Crystal Structure of Human AKT1 with an Allosteric Inhibitor Reveals a New Mode of Kinase Inhibition

    Get PDF
    AKT1 (NP_005154.2) is a member of the serine/threonine AGC protein kinase family involved in cellular metabolism, growth, proliferation and survival. The three human AKT isozymes are highly homologous multi-domain proteins with both overlapping and distinct cellular functions. Dysregulation of the AKT pathway has been identified in multiple human cancers. Several clinical trials are in progress to test the efficacy of AKT pathway inhibitors in treating cancer. Recently, a series of AKT isozyme-selective allosteric inhibitors have been reported. They require the presence of both the pleckstrin-homology (PH) and kinase domains of AKT, but their binding mode has not yet been elucidated. We present here a 2.7 Ă… resolution co-crystal structure of human AKT1 containing both the PH and kinase domains with a selective allosteric inhibitor bound in the interface. The structure reveals the interactions between the PH and kinase domains, as well as the critical amino residues that mediate binding of the inhibitor to AKT1. Our work also reveals an intricate balance in the enzymatic regulation of AKT, where the PH domain appears to lock the kinase in an inactive conformation and the kinase domain disrupts the phospholipid binding site of the PH domain. This information advances our knowledge in AKT1 structure and regulation, thereby providing a structural foundation for interpreting the effects of different classes of AKT inhibitors and designing selective ones

    Improving management of a mid-Atlantic coastal barrier island through assessment of habitat condition

    Get PDF
    AbstractTo achieve desired environmental outcomes, environmental condition and trends need to be rigorously measured and communicated to resource managers, scientists, and a broader general audience. However, there is often a disconnect between responsive ecosystem monitoring and decision making for strategic long-term management. This project demonstrates how historical monitoring data can be synthesized and used for future planning and decision making, thereby closing the management feedback cycle. This study linked disparate datasets, collected for a variety of purposes and across multiple temporal and spatial scales, in order to assess and quantify current habitat conditions. The results inform integrated resource management decision-making at Assateague Island National Seashore (Maryland and Virginia, USA) by using ecological reference conditions to identify monitoring needs, areas of high vulnerability, and areas with potential for improved management. The approach also provides a framework that can be applied in the future to assess the effectiveness of these management decisions on the condition of island habitats, and is a replicable demonstration of incorporating diverse monitoring datasets into an adaptive management cycle

    Comparison of devices used to measure blood pressure, grip strength and lung function: A randomised cross-over study

    Get PDF
    BACKGROUND: Blood pressure, grip strength and lung function are frequently assessed in longitudinal population studies, but the measurement devices used differ between studies and within studies over time. We aimed to compare measurements ascertained from different commonly used devices. METHODS: We used a randomised cross-over study. Participants were 118 men and women aged 45–74 years whose blood pressure, grip strength and lung function were assessed using two sphygmomanometers (Omron 705-CP and Omron HEM-907), four handheld dynamometers (Jamar Hydraulic, Jamar Plus+ Digital, Nottingham Electronic and Smedley) and two spirometers (Micro Medical Plus turbine and ndd Easy on-PC ultrasonic flow-sensor) with multiple measurements taken on each device. Mean differences between pairs of devices were estimated along with limits of agreement from Bland-Altman plots. Sensitivity analyses were carried out using alternative exclusion criteria and summary measures, and using multilevel models to estimate mean differences. RESULTS: The mean difference between sphygmomanometers was 3.9mmHg for systolic blood pressure (95% Confidence Interval (CI):2.5,5.2) and 1.4mmHg for diastolic blood pressure (95% CI:0.3,2.4), with the Omron HEM-907 measuring higher. For maximum grip strength, the mean difference when either one of the electronic dynamometers was compared with either the hydraulic or spring-gauge device was 4-5kg, with the electronic devices measuring higher. The differences were small when comparing the two electronic devices (difference = 0.3kg, 95% CI:-0.9,1.4), and when comparing the hydraulic and spring-gauge devices (difference = 0.2kg, 95% CI:-0.8,1.3). In all cases limits of agreement were wide. The mean difference in FEV1 between spirometers was close to zero (95% CI:-0.03,0.03), limits of agreement were reasonably narrow, but a difference of 0.47l was observed for FVC (95% CI:0.53,0.42), with the ndd Easy on-PC measuring higher. CONCLUSION: Our study highlights potentially important differences in measurement of key functions when different devices are used. These differences need to be considered when interpreting results from modelling intra-individual changes in function and when carrying out cross-study comparisons, and sensitivity analyses using correction factors may be helpful
    • …
    corecore