187 research outputs found
Recent Labour Market Trends in the Visegrad Group Countries
The large declines in the Slovak and Czech employment appeared because the countries' GDPs grew smaller while real wages grew bigger. Shorter working hours and limitations on labour productivity that the two countries introduced could not reverse the unfavourable employment trends that occurred during economic downturn.Duże spadki zatrudnienia w Słowacji i Czechach były związane ze słabym wzrostem PKB i silnym wzrostem płac realnych. Redukcje czasu pracy i wydajności pracy nie były w stanie odwrócić niekorzystnych tendencji w zatrudnieniu
Beam profile investigation of the new collimator system for the J-PET detector
Jagiellonian Positron Emission Tomograph (J-PET) is a multi-purpose detector
which will be used for search for discrete symmetries violations in the decays
of positronium atoms and for investigations with positronium atoms in
life-sciences and medical diagnostics. In this article we present three methods
for determination of the beam profile of collimated annihilation gamma quanta.
Precise monitoring of this profile is essential for time and energy calibration
of the J-PET detector and for the determination of the library of model signals
used in the hit-time and hit-position reconstruction. We have we have shown
that usage of two lead bricks with dimensions of 5x10x20 cm^3 enables to form a
beam of annihilation quanta with Gaussian profile characterized by 1 mm FWHM.
Determination of this characteristic is essential for designing and
construction the collimator system for the 24-module J-PET prototype.
Simulations of the beam profile for different collimator dimensions were
performed. This allowed us to choose optimal collimation system in terms of the
beam profile parameters, dimensions and weight of the collimator taking into
account the design of the 24 module J-PET detector.Comment: 14 pages, 9 figure
Searches for discrete symmetries violation in ortho-positronium decay using the J-PET detector
In this paper we present prospects for using the J-PET detector to search for
discrete symmetries violations in a purely leptonic system of the positronium
atom. We discuss tests of CP and CPT symmetries by means of ortho-positronium
decays into three photons. No zero expectation values for chosen correlations
between ortho-positronium spin and momentum vectors of photons would imply the
existence of physics phenomena beyond the Standard Model. Previous measurements
resulted in violation amplitude parameters for CP and CPT symmetries consistent
with zero, with an uncertainty of about 10-3. The J-PET detector allows to
determine those values with better precision thanks to a unique time and
angular esolution combined with a high geometrical acceptance. Achieving the
aforementioned is possible due to application of polymer scintillators instead
of crystals as detectors of annihilation quanta.Comment: in Nukleonika 201
Topological effects in the thermal properties of knotted polymer rings
The topological effects on the thermal properties of several knot
configurations are investigated using Monte Carlo simulations. In order to
check if the topology of the knots is preserved during the thermal fluctuations
we propose a method that allows very fast calculations and can be easily
applied to arbitrarily complex knots. As an application, the specific energy
and heat capacity of the trefoil, the figure-eight and the knots are
calculated at different temperatures and for different lengths. Short-range
repulsive interactions between the monomers are assumed. The knots
configurations are generated on a three-dimensional cubic lattice and sampled
by means of the Wang-Landau algorithm and of the pivot method. The obtained
results show that the topological effects play a key role for short-length
polymers. Three temperature regimes of the growth rate of the internal energy
of the system are distinguished.Comment: 7 pages, 12 figures, LaTeX + RevTeX. With respect to the first
version, in the second version the text has been improved and all figures are
now in black and whit
Studies of unicellular micro-organisms Saccharomyces cerevisiae by means of Positron Annihilation Lifetime Spectroscopy
Results of Positron Annihilation Lifetime Spectroscopy (PALS) and microscopic
studies on simple microorganisms: brewing yeasts are presented. Lifetime of
ortho - positronium (o-Ps) were found to change from 2.4 to 2.9 ns (longer
lived component) for lyophilised and aqueous yeasts, respectively. Also
hygroscopicity of yeasts in time was examined, allowing to check how water -
the main component of the cell - affects PALS parameters, thus lifetime of o-Ps
were found to change from 1.2 to 1.4 ns (shorter lived component) for the dried
yeasts. The time sufficient to hydrate the cells was found below 10 hours. In
the presence of liquid water an indication of reorganization of yeast in the
molecular scale was observed.
Microscopic images of the lyophilised, dried and wet yeasts with best
possible resolution were obtained using Inverted Microscopy (IM) and
Environmental Scanning Electron Microscopy (ESEM) methods. As a result visible
changes to the surface of the cell membrane were observed in ESEM images.Comment: Nukleonika (2015
Compressive Sensing of Signals Generated in Plastic Scintillators in a Novel J-PET Instrument
The J-PET scanner, which allows for single bed imaging of the whole human
body, is currently under development at the Jagiellonian University. The dis-
cussed detector offers improvement of the Time of Flight (TOF) resolution due
to the use of fast plastic scintillators and dedicated electronics allowing for
sam- pling in the voltage domain of signals with durations of few nanoseconds.
In this paper we show that recovery of the whole signal, based on only a few
samples, is possible. In order to do that, we incorporate the training signals
into the Tikhonov regularization framework and we perform the Principal
Component Analysis decomposition, which is well known for its compaction
properties. The method yields a simple closed form analytical solution that
does not require iter- ative processing. Moreover, from the Bayes theory the
properties of regularized solution, especially its covariance matrix, may be
easily derived. This is the key to introduce and prove the formula for
calculations of the signal recovery error. In this paper we show that an
average recovery error is approximately inversely proportional to the number of
acquired samples
Application of the Compress Sensing Theory for Improvement of the TOF Resolution in a Novel J-PET Instrument
Nowadays, in Positron Emission Tomography (PET) systems, a Time of Flight
information is used to improve the image reconstruction process. In Time of
Flight PET (TOF-PET), fast detectors are able to measure the difference in the
arrival time of the two gamma rays, with the precision enabling to shorten
significantly a range along the line-of-response (LOR) where the annihilation
occurred. In the new concept, called J-PET scanner, gamma rays are detected in
plastic scintillators. In a single strip of J-PET system, time values are
obtained by probing signals in the amplitude domain. Owing to Compress Sensing
theory, information about the shape and amplitude of the signals is recovered.
In this paper we demonstrate that based on the acquired signals parameters, a
better signal normalization may be provided in order to improve the TOF
resolution. The procedure was tested using large sample of data registered by a
dedicated detection setup enabling sampling of signals with 50 ps intervals.
Experimental setup provided irradiation of a chosen position in the plastic
scintillator strip with annihilation gamma quanta
PALS investigations of free volumes thermal expansion of J-PET plastic scintillator synthesized in polystyrene matrix
The polystyrene dopped with 2,5-diphenyloxazole as a primary fluor and
2-(4-styrylphenyl)benzoxazole as a wavelength shifter, prepared as a plastic
scintillator was investigated using positronium probe in wide range of
temperatures from 123 to 423 K. Three structural transitions at 260 K, 283 K
and 370 K were found in the material. In the o-Ps intensity dependence on
temperature, the significant hysteresis is observed. Heated to 370 K, the
material exhibits the o-Ps intensity variations in time.Comment: in Nukleonika 201
Novel method for hit-position reconstruction using voltage signals in plastic scintillators and its application to Positron Emission Tomography
Currently inorganic scintillator detectors are used in all commercial Time of
Flight Positron Emission Tomograph (TOF-PET) devices. The J-PET collaboration
investigates a possibility of construction of a PET scanner from plastic
scintillators which would allow for single bed imaging of the whole human body.
This paper describes a novel method of hit-position reconstruction based on
sampled signals and an example of an application of the method for a single
module with a 30 cm long plastic strip, read out on both ends by Hamamatsu
R4998 photomultipliers. The sampling scheme to generate a vector with samples
of a PET event waveform with respect to four user-defined amplitudes is
introduced. The experimental setup provides irradiation of a chosen position in
the plastic scintillator strip with an annihilation gamma quanta of energy
511~keV. The statistical test for a multivariate normal (MVN) distribution of
measured vectors at a given position is developed, and it is shown that signals
sampled at four thresholds in a voltage domain are approximately normally
distributed variables. With the presented method of a vector analysis made out
of waveform samples acquired with four thresholds, we obtain a spatial
resolution of about 1 cm and a timing resolution of about 80 p
- …