10 research outputs found
Metal-coated carbon nanotube tips for Magnetic Force Microscopy
We fabricated cantilevers for magnetic force microscopy with carbon nanotube
tips coated with magnetic material. Images of a custom hard drive demonstrated
20 nm lateral resolution, with prospects for further improvements.Comment: Accepted to be published in Applied Physics Letter
Recommended from our members
Mechanics of Individual, Isolated Vortices in a Cuprate Superconductor
Superconductors often contain quantized microscopic whirlpools of electrons, called vortices, that can be modelled as one-dimensional elastic objects1. Vortices are a diverse area of study for condensed matter because of the interplay between thermal fluctuations, vortex–vortex interactions and the interaction of the vortex core with the three-dimensional disorder landscape. Although vortex matter has been studied extensively, the static and dynamic properties of an individual vortex have not. Here, we use magnetic force microscopy (MFM) to image and manipulate individual vortices in a detwinned YBa2Cu3O6.991 single crystal, directly measuring the interaction of a moving vortex with the local disorder potential. We find an unexpected and marked enhancement of the response of a vortex to pulling when we wiggle it transversely. In addition, we find enhanced vortex pinning anisotropy that suggests clustering of oxygen vacancies in our sample and demonstrates the power of MFM to probe vortex structure and microscopic defects that cause pinning.Physic
Formulation of a Thermosensitive Imaging Hydrogel for Topical Application and Rapid Visualization of Tumor Margins in the Surgical Cavity
Background: Tumor-positive surgical margins during primary breast cancer (BCa) surgery are associated with a two-fold increase in the risk of local recurrence when compared with tumor-negative margins. Pathological microscopic evaluation of the samples only assesses about 1/10 of 1% of the entire volume of the removed BCa specimens, leading to margin under-sampling and potential local recurrence in patients with pathologically clean margins, i.e., false negative margins. In the case of tumor-positive margins, patients need to undergo re-excision and/or radiation therapy, resulting in increases in complications, morbidity, and healthcare costs. Development of a simple real-time imaging technique to identify residual BCa in the surgical cavity rapidly and precisely could significantly improve the quality of care. Methods: A small-molecule, fluorescently quenched protease-substrate probe, AKRO-QC-ICG, was tested as part of a thermosensitive imaging gel formulated for topical application and imaging of the BCa surgical cavity. Results: More than forty formulations of gel mixtures were investigated to enable easy fluid application and subsequent solidification once applied, preventing dripping and pooling in the surgical cavity. The final formulation was tested using human BCa orthotopic implants in nude and NSG patient-derived xenografts (PDX) mice. This formulation of Pluronic F-127/DMSO/AKRO-QC-ICG imaging gel was found to be a good solvent for the probe, with a desirable thermo-reversible solid–gel transition and mechanical strength for distribution of AKRO-QC-ICG on the surfaces of tissue. It demonstrated excellent ability to detect BCa tissue after 10 min exposure, with a high signal-to-noise ratio both in mouse xenografts and freshly excised human lumpectomy tissue. The in vivo efficacy of the AKRO-QC-ICG imaging gel to detect BCa revealed the levels of sensitivity/specificity = 0.92/1 in 12 nude mice, which was corroborated with the sensitivity/specificity = 0.94/1 in 10 PDX mice. Conclusions: Utilization of Pluronic F-127/DMSO/AKRO-QC-ICG imaging gel for topical application to detect BCa in the surgical cavity during surgery has the potential to reduce re-excisions, with consequent savings in healthcare costs and enhancement in patient quality of life
Noninvasive prenatal testing using a novel analysis pipeline to screen for all autosomal fetal aneuploidies improves pregnancy management
Noninvasive prenatal testing by massive parallel sequencing of maternal plasma DNA has rapidly been adopted as a mainstream method for detection of fetal trisomy 21, 18 and 13. Despite the relative high accuracy of current NIPT testing, a substantial number of false-positive and false-negative test results remain. Here, we present an analysis pipeline, which addresses some of the technical as well as the biologically derived causes of error. Most importantly, it differentiates high z-scores due to fetal trisomies from those due to local maternal CNVs causing false positives. This pipeline was retrospectively validated for trisomy 18 and 21 detection on 296 samples demonstrating a sensitivity and specificity of 100%, and applied prospectively to 1350 pregnant women in the clinical diagnostic setting with a result reported in 99.9% of cases. In addition, values indicative for trisomy were observed two times for chromosome 7 and once each for chromosomes 15 and 16, and once for a segmental trisomy 18. Two of the trisomies were confirmed to be mosaic, one of which contained a uniparental disomy cell line. As placental trisomies pose a risk for low-grade fetal mosaicism as well as uniparental disomy, genome-wide noninvasive aneuploidy detection is improving prenatal management
Measurement of the mass of the Z boson and the energy calibration of LEP
In 1985 the French government created a unique circuit for the dissemination of doctoral theses: References went to a national database “Téléthèses” whereas the documents were distributed to the university libraries in microform. In the era of the electronic document this French network of deposit of and access to doctoral theses is changing. How do you discover and locate a French thesis today, how do you get hold of a paper copy and how do you access the full electronic text? What are the catalogues and databases referencing theses since the disappearance of “Téléthèses”? Where are the archives, and are they open? What is the legal environment that rules the emerging structures and tools? This paper presents national plans on referencing and archiving doctoral theses coordinated by the government as well as some initiatives for creating full text archives. These initiatives come from universities as well as from research institutions and learned societies. “Téléthèses” records have been integrated in a union catalogue of French university libraries SUDOC. University of Lyon-2 and INSA Lyon developed procedures and tools covering the entire production chain from writing to the final access in an archive: “Cyberthèses” and “Cither”. The CNRS Centre for Direct Scientific Communication at Lyon (CCSD) maintains an archive (“TEL”) with about 2000 theses in all disciplines. Another repository for theses in engineering, economics and management called “Pastel” is proposed by the Paris Institute of Technology (ParisTech), a consortium of 10 engineering and commercial schools of the Paris region