457 research outputs found

    Undetected patricide: Inaccuracy of cause of death determination without an autopsy

    Get PDF
    Patricide (killing the father) is uncommon form of homicide. Usually the assaults occur at home in the absence of witnesses and adult sons are frequently involved. Homicides in a domestic context usually do not tend to recurrence, because the motivation for the crime ends with the death of the parent. However, this is not what was observed in the present case study dealing with the death of a 70 years old white man originally misclassified as accident and discovered three years later only after an additional homicide in a family context of a 60 years old white lady. Multiple stab wounds to the neck and thorax were misinterpreted at the external male body examination as blunt trauma falling down stairs. No forensic autopsy was requested and no comparison of medical findings with the results from the death scene, such as a bloodstain analysis was performed by the police officers nor required by the judicial authority. This was quite surprising because an additional but preliminary post-mortem external examination performed by a general practitioner on the male body already raised the suspicion that the external lesions were stab wounds thus requiring a forensic autopsy. Only the exhumation of the elderly body, performed years later, confirmed the diagnostic hypothesis raised by the first physician. The present case is quite representative of a death investigation not run professionally and performed by individuals with no specific training where most of the medico-legal investigations (especially for traumatic and violent deaths) are restricted to an external body examination without subsequent autopsy. Although misinterpretation of external lesions is inevitable and significant discrepancies between external body examination and forensic autopsy are not rare, in the case of contradictory results of postmortem external examination or unclear/suspicious cause and manner of death, investigation should proceed necessarily with a forensic autopsy

    Titanium Nitride Coating of RF Ceramic Windows by Reactive DC Magnetron Sputtering

    No full text
    International audienceLAL-Orsay is developing an important effort on R&D and technology studies on RF power couplers for superconductive cavities. These are complex and high technology devices due to their basic functions: vacuum and temperature separation form the environment to the cavity. One of the most critical components of high power couplers is the ceramic RF window that allows the power flux to be injected in the coaxial line. The presence of a dielectric window on a high power RF line has in fact a strong influence on the multipactor phenomena, a resonant electron discharge that is strongly limiting for the RF components performances. The most important method to reduce the multipactor is to decrease the secondary emission yield of the ceramic window. Due to its low secondary electron emission coefficient, TiN thin film is used as a multipactor suppressor coating on RF ceramic coupler windows. In the framework of the EU program FP6 the LAL-Orsay and the LNL-Legnaro establish a collaboration to develop a coating bench that takes into account the different strong constraints on stoechiometry and film coating thickness given by coupler operating conditions. Reactive magnetron sputtering technology was chosen to obtain such deposit. A full description of a sputtering bench recently installed in LAL, and its main characteristics are given. Stoechiometric TiN films are obtained by optimization of reactive gas flow (N2), for a given bias and a given ionisation gas flow (Ar). XRD analysis was performed to control film composition. From the data obtained, lattice parameter is calculated for each deposit and film stoechiometry is determined. XPS analysis of stoechiometric film had shown the existence of oxygen and carbon mainly in the surface. However, it shows also that the ratio Ti/N in atomic percentage is equal to 1

    Clickable cellulosic surfaces for peptide-based bioassays

    Get PDF
    The use of peptides in paper-based analytics is a highly appealing field, yet it suffers from severe limitations. This is mostly due to the loss of effective target recognition properties of this relatively small probes upon nonspecific adsorption onto cellulose substrates. Here we address this issue by introducing a simple polymer-based strategy to obtain clickable cellulose surfaces, that we exploited for the chemoselective bioconjugation of peptide bioprobes. Our method largely outperformed standard adsorption-based immobilization strategy in a challenging, real case immunoassay, namely the diagnostic discrimination of Zika + individuals from healthy controls. Of note, the clickable polymeric coating not only allows efficient peptides bioconjugation, but it provides favorable anti-fouling properties to the cellulosic support. We envisage our strategy to broaden the repertoire of cellulosic materials manipulation and promote a renewed interest in peptide-based paper bioassays

    Radioisotopic purity and imaging properties of cyclotron-produced 99mTc using direct 100Mo(p,2n) reaction

    Get PDF
    Evaluation of the radioisotopic purity of technetium-99m (99mTc) produced in GBq amounts by proton bombardment of enriched molibdenum-100 (100Mo) metallic targets at low proton energies (i.e. within 15\u201320 MeV) is conducted. This energy range was chosen since it is easily achievable by many conventional medical cyclotrons already available in the nuclear medicine departments of hospitals. The main motivation for such a study is in the framework of the research activities at the international level that have been conducted over the last few years to develop alternative production routes for the most widespread radioisotope used in medical imaging. The analysis of technetium isotopes and isomeric states (9xTc) present in the pertechnetate saline Na99mTcO4 solutions, obtained after the extraction/purification procedure, reveals radionuclidic purity levels basically in compliance with the limits recently issued by European Pharmacopoeia 9.3 (2018 Sodium pertechnetate (99mTc) injection 4801\u20133). Moreover, the impact of 9xTc contaminant nuclides on the final image quality is thoroughly evaluated, analyzing the emitted high-energy gamma rays and their influence on the image quality. The spatial resolution of images from cyclotron-produced 99mTc acquired with a mini-gamma camera was determined and compared with that obtained using technetium-99m solutions eluted from standard 99Mo/99mTc generators. The effect of the increased image background contribution due to Compton-scattered higher-energy gamma rays (E \u3b3 \u2009\u2009>\u2009\u2009200\u2009keV), which could cause image-contrast deterioration, was also studied. It is concluded that, due to the high radionuclidic purity of cyclotron-produced 99mTc using 100Mo(p,2n)99mTc reaction at a proton beam energy in the range 15.7\u201319.4 MeV, the resulting image properties are well comparable with those from the generator-eluted 99mTc

    Cryphonectric acid and other minor metabolites from a hypovirulent strain of Cryphonectria parasitica

    Get PDF
    Investigations carried out on secondary metabolites produced in culture by a hypovirulent strain of Cryphonectria parasitica allowed the isolation of several compounds which were characterized by NMR analysis and derivatization reactions. The most abundant metabolite was a new compound, called cryphonectric acid (1). Other metabolites were diaporthin, the only known phytotoxic compound isolated from both virulent and hypovirulent strains of C. parasitica, (+)-orthosporin, and L-p-hydroxyphenyllactic acid (HOPLA). Root growth activity of the purified compounds was evaluated both on tomato seedlings and maize subapical segments

    The Middle Triassic lagerstätt e of Monte San Giorgio reveals the oldest lace bugs (Hemiptera: Tingidae): Archetingis ladinica gen. n. sp. n.

    Get PDF
    A new genus and species of fossil lace bugs (Hemiptera; Tingidae), Archetingis ladinica gen. n. et sp. n. is described from the lower Kalkschieferzone (Meride Limestone, Upper Ladinian) of the Swiss side of Monte San Giorgio. The new taxon clearly resembles modern Tingidae in its hemelytra and pronotum, with two rows of areole, in the presence of bucculae closed at the anterior end, not extending beyond the apex of the head, and in the presence of a labial groove on the meso-/metathoracic sternum. Distinctive features are the thick femurs of the first and second pair of legs, the exceptional size (total length of ~12 mm) if compared with both fossil and extant species. Archetingis ladinica gen. n. et sp. n. represents by far the oldest known species of this family and brings back the origin of Tingidae of approximately 140 My, well into the Middle Triassic. The discovery of A. ladinica, beside its evolutionary consequences on the origin of extant Tingidae, provides evidences for the presence of terrestrial ecosystems nearby to the depositional environment. According to the living and trophic behavior of extant Tingidae, those emerged lands had to be covered by vegetation

    ABCD2, ABCD2-I, and OTTAWA scores for stroke risk assessment: a direct retrospective comparison

    Get PDF
    Transient ischemic attack (TIA) is a neurologic emergency characterized by cerebral ischemia eliciting a temporary focal neurological deficit. Many clinical prediction scores have been proposed to assess the risk of stroke after TIA; however, studies on their clinical validity and comparisons among them are scarce. The objective is to compare the accuracy of ABCD2, ABCD2-I, and OTTAWA scores in the prediction of a stroke at 7, 90 days, and 1 year in patients presenting with TIA. Single-centre, retrospective study including patients with TIA admitted to the Emergency Department of our third-level, University Hospital, between 2018 and 2019. Five hundred three patients were included. Thirty-nine (7.7%) had a stroke within 1 year from the TIA: 9 (1.7%) and 24 (4.7%) within 7 and 90 days, respectively. ABCD2, ABCD2-I, and OTTAWA scores were significantly higher in patients who developed a stroke. AUROCs ranged from 0.66 to 0.75, without statistically significant differences at each time-point. Considering the best cut-off of each score, only ABCD2 > 3 showed a sensitivity of 100% only in the prediction of stroke within 7 days. Among clinical items of each score, duration of symptoms, previous TIA, hemiparesis, speech disturbance, gait disturbance, previous cerebral ischemic lesions, and known carotid artery disease were independent predictors of stroke. Clinical scores have moderate prognostic accuracy for stroke after TIA. Considering the independent predictors for stroke, our study indicates the need to continue research and prompts the development of new tools on predictive scores for TIA
    • …
    corecore