56 research outputs found

    The longest functioning heart valve prosthesis?

    Get PDF

    Less invasive aortic valve surgery: rationale and technique

    Get PDF
    The unquestionable aims for a less invasive operations are less morbidity, less discomfort, and a reduced hospital stay through an operation which proves equally durable to the conventional approach. Such an operation must be carried out without further risk to the patient or increased difficulty for the surgeon. Whilst most definitions of less invasive coronary surgery include the phrase without cardiopulmonary bypass, this is clearly not yet possible in valve surgery. In valve surgery, the definition of less invasive relates only to the size of incision and rate of recovery. As a result of the discussions during the Heart Lab International Workshop on video-assisted heart surgery in ZĂźrich, October 22-25, 1998, the following conclusions emerged. The partial upper sternotomy with J- or L- shaped extension to the right is the preferred approach for minimally invasive aortic valve surgery. Other methods which sacrify the internal thoracic arteries, open pleural cavities or predispose to long hernia are less satisfactory. A detailed description of the technique proposed is given and its indications and contraindications are discusse

    Hybrid approach of ventricular assist device and autologous bone marrow stem cells implantation in end-stage ischemic heart failure enhances myocardial reperfusion

    Get PDF
    We challenge the hypothesis of enhanced myocardial reperfusion after implanting a left ventricular assist device together with bone marrow mononuclear stem cells in patients with end-stage ischemic cardiomyopathy. Irreversible myocardial loss observed in ischemic cardiomyopathy leads to progressive cardiac remodelling and dysfunction through a complex neurohormonal cascade. New generation assist devices promote myocardial recovery only in patients with dilated or peripartum cardiomyopathy. In the setting of diffuse myocardial ischemia not amenable to revascularization, native myocardial recovery has not been observed after implantation of an assist device as destination therapy. The hybrid approach of implanting autologous bone marrow stem cells during assist device implantation may eventually improve native cardiac function, which may be associated with a better prognosis eventually ameliorating the need for subsequent heart transplantation. The aforementioned hypothesis has to be tested with well-designed prospective multicentre studies

    Has increased clinical experience with methotrexate reduced the direct costs of medical management of ectopic pregnancy compared to surgery?

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>There is a debate about the cost-efficiency of methotrexate for the management of ectopic pregnancy (EP), especially for patients presenting with serum human chorionic gonadotrophin levels of >1500 IU/L. We hypothesised that further experience with methotrexate, and increased use of guideline-based protocols, has reduced the direct costs of management with methotrexate.</p> <p>Methods</p> <p>We conducted a retrospective cost analysis on women treated for EP in a large UK teaching hospital to (1) investigate whether the cost of medical management is less expensive than surgical management for those patients eligible for both treatments and (2) to compare the cost of medical management for women with hCG concentrations 1500–3000 IU/L against those with similar hCG concentrations that elected for surgery. Three distinct treatment groups were identified: (1) those who had initial medical management with methotrexate, (2) those who were eligible for initial medical management but chose surgery (‘elected’ surgery) and (3) those who initially ‘required’ surgery and did not meet the eligibility criteria for methotrexate. We calculated the costs from the point of view of the National Health Service (NHS) in the UK. We summarised the cost per study group using the mean, standard deviation, median and range and, to account for the skewed nature of the data, we calculated 95% confidence intervals for differential costs using the nonparametric bootstrap method.</p> <p>Results</p> <p>Methotrexate was £1179 (CI 819–1550) per patient cheaper than surgery but there were no significant savings with methotrexate in women with hCG >1500 IU/L due to treatment failures.</p> <p>Conclusions</p> <p>Our data support an ongoing unmet economic need for better medical treatments for EP with hCG >1500 IU/L.</p

    The CentriMag Centrifugal Blood Pump as a Benchmark for In Vitro Testing of Hemocompatibility in Implantable Ventricular Assist Devices

    Get PDF
    Abstract: Implantable ventricular assist devices (VADs) have proven efficient in advanced heart failure patients as a bridge-to-transplant or destination therapy. However, VAD usage often leads to infection, bleeding, and throm-bosis, side effects attributable to the damage to blood cells and plasma proteins. Measuring hemolysis alone does not provide sufficient information to understand total blood damage, and research exploring the impact of cur-rently available pumps on a wider range of blood cell types and plasma proteins such as von Willebrand factor (vWF) is required to further our understanding of safer pump design. The extracorporeal CentriMag (Thoratec Corporation, Pleasanton, CA, USA) has a hemolysis profile within published standards of normalized index of hemolysis levels of less than 0.01 g/100 L at 100 mm Hg bu

    Extra-corporeal membrane oxygenation for refractory cardiogenic shock after adult cardiac surgery:a systematic review and meta-analysis

    Get PDF
    Background - Postcardiotomy cardiogenic shock (PCCS) refractory to inotropic support and intra-aortic balloon pump (IABP) occurs rarely but is almost universally fatal without mechanical circulatory support. In this systematic review and meta-analysis we looked at the evidence behind the use of veno-arterial extra-corporeal membrane oxygenation (VA ECMO) in refractory PCCS from a patient survival rate and determinants of outcome viewpoint. Methods - A systematic review was performed in January 2017 using PubMed (with no defined time period) using the keywords “postcardiotomy”, “cardiogenic shock”, “extracorporeal membrane oxygenation” and “cardiac surgery”. We excluded papers pertaining to ECMO following paediatric cardiac surgery, medical causes of cardiogenic shock, as well as case reports, review articles, expert opinions, and letters to the editor. Once the studies were collated, a meta-analysis was performed on the proportion of survivors in those papers that met the inclusion criteria. Meta-regression was performed for the most commonly reported adverse prognostic indicators (API). Results - We identified 24 studies and a cumulative pool of 1926 patients from 1992 to 2016. We tabulated the demographic data, including the strengths and weaknesses for each of the studies, outcomes of VA ECMO for refractory PCCS, complications, and APIs. All the studies were retrospective cohort studies. Meta-analysis of the moderately heterogeneous data (95% CI 0.29 to 0.34, p 70 years, 95% CI −0.057 to 0.001, P = 0.058), and long ECMO support (95% CI −0.068 to 0.166, P = 0.412). Postoperative renal failure, high EuroSCORE (>20%), diabetes mellitus, obesity, rising lactate whilst on ECMO, gastrointestinal complications had also been reported. Conclusion - Haemodynamic support with VA ECMO provides a survival benefit with reasonable intermediate and long-term outcomes. Many studies had reported advanced age, renal failure and prolonged VA ECMO support as the most likely APIs for VA ECMO in PCCS. EuroSCORE can be utilized to anticipate the need for prophylactic perioperative VA ECMO in the high-risk category. APIs can be used to aid decision-making regarding both the institution and weaning of ECMO for refractory PCCS

    Towards a realistic artificial heart

    No full text
    SIGLEAvailable from British Library Document Supply Centre- DSC:DXN056179 / BLDSC - British Library Document Supply CentreGBUnited Kingdo
    • …