4 research outputs found

    Practical observations on the performance of bare silica in hydrophilic interaction compared with C18 reversed-phase liquid chromatography

    Get PDF
    The kinetic performance of a bare silica and C18 phase prepared from the same sub-2. μm and 3.5. μm base materials were compared in the HILIC and RP mode using both charged and neutral solutes. The HILIC column was characterised using the neutral solute 5-hydroxymethyluridine, the weak base cytosine, and the strong base nortriptyline, the latter having sufficient retention also in the RP mode to allow comparison of performance. Naphthalene was also used as a simple neutral substance to evaluate the RP column alone. The retention factors of all substances were adjusted to give similar values (k'. ~. 5.5) at their respective optimum linear velocities. Reduced van Deemter b-coefficients (determined by curve fitting and by the peak parking method, using a novel procedure involving switching to a dummy column) were significantly lower in HILIC for all substances compared with those found under RP conditions. Against expectation, c-coefficients were always lower in RP when compared with HILIC using sub-2. μm particles. While measurement of these coefficients is complicated by retention shifts caused by the influence of high pressure and by frictional heating effects, broadly similar results were obtained on larger particle (3.5. μm) phases. The mechanism of the separations was further investigated by examining the effect of buffer concentration on retention. It was concluded that HILIC can sometimes show somewhat inferior performance to RP for fast analysis at high mobile phase velocity, but clearly shows advantages when high column efficiencies, using longer columns at low flow velocity, are employed. The latter result is attributable to the lower viscosity of the mobile phase in HILIC and the reduced pressure requirement as well as the lower b-coefficients. © 2014 David V. McCalley

    Overloading study of bases using polymeric RP-HPLC columns as an aid to rationalization of overloading on silica-ODS phases

    No full text
    The separation of ionized bases by reversed-phase liquid chromatography with alkyl silica columns often leads to severely tailed bands that are highly detrimental. Band shape and its dependence on sample mass are notably different when mobile-phase pH is changed, and this behavior has not been previously explained. Ionized silanols present in the stationary phase have been credited with a role in determining peak shape. In the present study, separations on two different polymer columns were compared with those previously obtained on alkyl silica phases. Because silanols are absent from polymer columns, this comparison enabled us to assess the role of silanols in separations on alkyl silica phases and to offer an explanation of why band shape changes with sample size and mobile-phase pH for both polymer and silica-based phases

    Influence of phase type and solute structure on changes in retention with pressure in reversed-phase high performance liquid chromatography

    No full text
    The influence of pressure on the retention of several types of solute, including acids, bases and neutrals, was studied by the use of restriction capillaries added to the end of various monomeric and polymeric octadecylsilyl-modified 5. μm particle size columns. Although it appeared that certain polymeric columns could give somewhat greater increases in retention with pressure, differences in behaviour between these different C18 columns were rather small. Differences in solute molecular size were most important in determining increases in retention with pressure. However, solute structure such as polarity and planarity were also influential. A prototype C30 column gave interesting selectivity changes between planar and non-planar solutes as a function of pressure. Considerable selectivity differences with pressure were shown when diverse mixtures of solutes were analysed. For the solutes studied, only minor effects of increased pressure on column efficiency and peak shape were noted. © 2013 Elsevier B.V