10 research outputs found

    Effect of reader experience on variability, evaluation time and accuracy of coronary plaque detection with computed tomography coronary angiography

    Get PDF
    Objective: To assess the effect of reader experience on variability, evaluation time and accuracy in the detection of coronary artery plaques with computed tomography coronary angiography (CTCA). Methods: Three independent, blinded readers with three different experience levels twice labelled 50 retrospectively electrocardiography (ECG)-gated contrast-enhanced dual-source CTCA data sets (15 female, age 67.3 ± 10.4years, range 46-86years) indicating the presence or absence of coronary plaques. The evaluation times for the readings were recorded. Intra- and interobserver variability expressed as κ statistics and sensitivity, specificity, and negative and positive predictive values were calculated for plaque detection, with a consensus reading of the three readers taken as the standard of reference. A bootstrap method was applied in the statistical analysis to account for clustering. Results: Significant correlations were found between reader experience and, respectively, evaluation times (r = −0.59, p < 0.05) and intraobserver variability (r = 0.73, p < 0.05). The evaluation time significantly differed among the readers (p < 0.05). The observer variability for plaque detection, compared with the consensus, varied between κ = 0.582 and κ = 0.802. Variability of plaque detection was significantly smaller (p < 0.05) and more accurate (p < 0.05) for the most experienced reader. Conclusion: Reader experience significantly correlated with observer variability, evaluation time and accuracy of coronary plaque detection at CTC

    High-pitch dual-source CT angiography of the aortic valve-aortic root complex without ECG-synchronization

    Get PDF
    Purpose: To compare image quality and radiation dose of high-pitch computed tomography angiography(CTA) of the aortic valve-aortic root complex with and without prospective ECG-gating compared to a retrospectively ECG-gated standard-pitch acquisition. Materials and Methods: 120 patients(mean age 68 ± 13years) were examined using a 128-slice dual-source CT system using prospectively ECG-gated high-pitch(group A; n = 40), non-ECG-gated high-pitch(group B; n = 40) or retrospectively ECG-gated standard-pitch(C; n = 40) acquisition techniques. Image quality of the aortic root, valve and ascending aorta including the coronary ostia was assessed by two independent readers. Image noise was measured, radiation dose estimates were calculated. Results: Interobserver agreement was good(κ = 0.64-0.78). Image quality was diagnostic in 38/40 patients(group A), 37/40(B) and 38/40(C) with no significant difference in number of patients with diagnostic image quality among all groups (p = 0.56). Significantly more patients showed excellent image quality in group A compared to groups B and C(each, p < 0.01). Average image noise was significantly different between all groups(p < 0.05). Mean radiation dose estimates in groups A and B(each; 2.4 ± 0.3mSv) were significantly lower compared to group C(17.5 ± 4.4mSv; p < 0.01). Conclusion: High-pitch dual-source CTA provides diagnostic image quality of the aortic valve-aortic root complex even without ECG-gating at 86% less radiation dose when compared to a standard-pitch ECG-gated acquisitio

    Dual-energy CT with tin filter technology for the discrimination of renal lesion proxies containing blood, protein, and contrast-agent. An experimental phantom study

    Get PDF
    Purpose: To differentiate proxy renal cystic lesions containing protein, blood, iodine contrast or saline solutions using dual-energy CT (DECT) equipped with a new tin filter technology (TFT). Materials and methods: 70 proxies (saline, protein, blood and contrast agent) were placed in unenhanced and contrast-enhanced kidney phantoms. DECT was performed at 80/140kV with and without tin filtering. Two readers measured the CT attenuation values in all proxies twice. An 80/140kV ratio was calculated. Results: All intra- and interobserver agreements were excellent (r = 0.93-0.97; p  0.05). The CT attenuation of protein, blood and contrast agent solution differed significantly with tin filtering (p < 0.01-0.05). Significant differences were found between the ratios of protein and blood compared to contrast medium solution (each, p < 0.05) and between the ratios of protein and blood in both phantoms with tin filtering (each, p < 0.05). Conclusion: DECT allows discrimination between a proxy renal lesion containing contrast agent and lesions containing protein and blood through their different attenuation at 80kV and 140kV. Further discrimination between protein and blood containing proxies is possible when using a tin filte

    Safe, effective and durable epicardial left atrial appendage clip occlusion in patients with atrial fibrillation undergoing cardiac surgery: first long-term results from a prospective device trial

    Get PDF
    OBJECTIVES Atrial fibrillation (AF) is a significant risk factor for embolic stroke originating from the left atrial appendage (LAA). This is the first report of long-term safety and efficacy data on LAA closure using a novel epicardial LAA clip device in patients undergoing cardiac surgery. METHODS Forty patients with AF were enrolled in this prospective ‘first-in-man' trial. The inclusion criterion was elective cardiac surgery in adult patients with AF for which a concomitant ablation procedure was planned. Intraoperative transoesophageal echocardiography (TEE) was used to exclude LAA thrombus at baseline and evaluate LAA perfusion after the procedure, while computed tomography (CT) was used for serial imagery workup at baseline, 3-, 12-, 24- and 36-month follow-up. RESULTS Early mortality was 10% due to non-device-related reasons, and thus 36 patients were included in the follow-up consisting of 1285 patient-days and mean duration of 3.5 ± 0.5 years. On CT, clips were found to be stable, showing no secondary dislocation 36 months after surgery. No intracardial thrombi were seen, none of the LAA was reperfused and in regard to LAA stump, none of the patients demonstrated a residual neck >1 cm. Apart from one unrelated transient ischaemic attack (TIA) that occurred 2 years after surgery in a patient with carotid plaque, no other strokes and/or neurological events demonstrated in any of the studied patients during follow-up. CONCLUSION This is the first prospective trial in which concomitant epicardial LAA occlusion using this novel epicardial LAA clip device is 100% effective, safe and durable in the long term. Closure of the LAA by epicardial clipping is applicable to all-comers regardless of LAA morphology. Minimal access epicardial LAA clip closure may become an interesting therapeutic option for patients in AF who are not amenable to anticoagulation and/or catheter closure. Further data are necessary to establish LAA occlusion as a true and viable therapy for stroke prevention. CLINICAL TRIAL REGISTRATION The trial is registered at www.ClinicalTrials.gov, reference: NCT0056751

    High-pitch dual-source CT angiography of the aortic valve-aortic root complex without ECG-synchronization.

    Full text link
    PURPOSE: To compare image quality and radiation dose of high-pitch computed tomography angiography(CTA) of the aortic valve-aortic root complex with and without prospective ECG-gating compared to a retrospectively ECG-gated standard-pitch acquisition. MATERIALS AND METHODS: 120 patients(mean age 68 +/- 13 years) were examined using a 128-slice dual-source CT system using prospectively ECG-gated high-pitch(group A; n = 40), non-ECG-gated high-pitch(group B; n = 40) or retrospectively ECG-gated standard-pitch(C; n = 40) acquisition techniques. Image quality of the aortic root, valve and ascending aorta including the coronary ostia was assessed by two independent readers. Image noise was measured, radiation dose estimates were calculated. RESULTS: Interobserver agreement was good(kappa = 0.64-0.78). Image quality was diagnostic in 38/40 patients(group A), 37/40(B) and 38/40(C) with no significant difference in number of patients with diagnostic image quality among all groups (p = 0.56). Significantly more patients showed excellent image quality in group A compared to groups B and C(each, p < 0.01). Average image noise was significantly different between all groups(p < 0.05). Mean radiation dose estimates in groups A and B(each; 2.4 +/- 0.3 mSv) were significantly lower compared to group C(17.5 +/- 4.4 mSv; p < 0.01). CONCLUSION: High-pitch dual-source CTA provides diagnostic image quality of the aortic valve-aortic root complex even without ECG-gating at 86% less radiation dose when compared to a standard-pitch ECG-gated acquisition

    Dual-source versus 64-section CT coronary angiography at lower heart rates: comparison of accuracy and radiation dose

    Full text link
    Purpose: To compare the diagnostic performance and radiation doses of dual-source and 64-section computed tomographic (CT) coronary angiography for the diagnosis of significant coronary stenoses in patients with heart rates of 65 beats/min or less. Materials and Methods: This retrospective study had local ethics committee approval; all patients gave written informed consent. Two hundred patients with heart rates of 65 beats/min or less were enrolled; 100 underwent dual-source and 100 underwent 64-section CT coronary angiography. Two blinded observers independently assessed image quality of all coronary segments by using a four-point scale and searched for significant (>50%) stenoses in each segment. Catheter angiography was used as the reference standard. Image noise was measured in the ascending aorta. Radiation doses were calculated. Results: No significant differences were found regarding sex, age, body weight, cardiovascular risk profile, prevalence of stenosis, mean and variability of heart rate, Agatston score, and image noise (all P > .1) between patients in both CT coronary angiography groups. No significant difference was found in the rate of nonassessable coronary segments between dual-source (1.0%, 14 of 1405) and 64-section CT coronary angiography (1.8%, 25 of 1387; P = .08). Motion artifacts occurred significantly more often in 64-section (21 of 25) versus dual-source (five of 14, P = .004) CT coronary angiography. Segment-based accuracy and specificity were significantly higher for dual-source versus 64-section CT coronary angiography. There was no significant difference in accuracy parameters at the per-vessel and per-patient analyses. No significant difference (P = .13) was found between the effective doses of dual-source (mean +/- standard deviation, 10.9 mSv +/- 1.1) and 64-section CT (10.4 mSv +/- 1.7) coronary angiography. Conclusion: In patients with heart rates of 65 beats/min or less, the higher temporal resolution of dual-source CT coronary angiography results in improved accuracy and specificity for the diagnosis of significant stenoses on a per-segment level at a similar radiation dose, but provides a comparable diagnostic accuracy on a patient-based level as does 64-section coronary angiography. (c) RSNA, 2009

    Long-term follow-up, computed tomography, and computational fluid dynamics of the Cabrol procedure

    Get PDF
    OBJECTIVES: The Cabrol procedure is characterized by insertion of an ascending aortic composite graft with reimplantation of the coronary arteries by the interposition of a graft tube. Our purpose is to report the clinical long-term follow-up and computed tomographic findings in patients having undergone the Cabrol procedure and to determine blood flow in the Cabrol graft using computational fluid dynamics. METHODS: Clinical follow-up (76.6 +/- 16.6 months) and dual-source computed tomographic angiography data of 7 patients (all men, mean age 54.9 +/- 9.6 years) with 12 Cabrol grafts (left main coronary artery, n = 7; right coronary artery, n = 5) were reviewed. In 2 patients, the right coronary artery was directly reattached to the aortic graft. Computational fluid dynamics were calculated using computed tomographic data of a patient with the Cabrol procedure and compared with those in a Valsalva graft and a healthy aortic root. RESULTS: Computed tomography showed Cabrol graft occlusions to 1 of 7 (14%) left main and of 2 of 5 (40%) right coronary arteries. Six grafts to the left main and 3 to the right coronary artery were fully patent, similar to the 2 directly reattached right coronary arteries to the aortic graft. Computational fluid dynamics results show similar blood flow parameters into the coronaries for the healthy aortic root and Valsalva graft. In the Cabrol graft, a spiraling flow pattern with low flow into the right coronary artery was found (right coronary artery = 1 mL/min at both systole and diastole). CONCLUSIONS: Our study indicates low flow rates particularly in the right Cabrol graft correlating with a higher incidence of occlusions of the right as compared with the left Cabrol graft at long-term follow-up

    Dual-energy CT with tin filter technology for the discrimination of renal lesion proxies containing blood, protein, and contrast-agent. An experimental phantom study

    Full text link
    PURPOSE: To differentiate proxy renal cystic lesions containing protein, blood, iodine contrast or saline solutions using dual-energy CT (DECT) equipped with a new tin filter technology (TFT). MATERIALS AND METHODS: 70 proxies (saline, protein, blood and contrast agent) were placed in unenhanced and contrast-enhanced kidney phantoms. DECT was performed at 80/140 kV with and without tin filtering. Two readers measured the CT attenuation values in all proxies twice. An 80/140 kV ratio was calculated. RESULTS: All intra- and interobserver agreements were excellent (r = 0.93-0.97; p 0.05). The CT attenuation of protein, blood and contrast agent solution differed significantly with tin filtering (p < 0.01-0.05). Significant differences were found between the ratios of protein and blood compared to contrast medium solution (each, p < 0.05) and between the ratios of protein and blood in both phantoms with tin filtering (each, p < 0.05). CONCLUSION: DECT allows discrimination between a proxy renal lesion containing contrast agent and lesions containing protein and blood through their different attenuation at 80 kV and 140 kV. Further discrimination between protein and blood containing proxies is possible when using a tin filter

    Safe, effective and durable epicardial left atrial appendage clip occlusion in patients with atrial fibrillation undergoing cardiac surgery: first long-term results from a prospective device trial

    Full text link
    OBJECTIVES: Atrial fibrillation (AF) is a significant risk factor for embolic stroke originating from the left atrial appendage (LAA). This is the first report of long-term safety and efficacy data on LAA closure using a novel epicardial LAA clip device in patients undergoing cardiac surgery. METHODS: Forty patients with AF were enrolled in this prospective 'first-in-man' trial. The inclusion criterion was elective cardiac surgery in adult patients with AF for which a concomitant ablation procedure was planned. Intraoperative transoesophageal echocardiography (TEE) was used to exclude LAA thrombus at baseline and evaluate LAA perfusion after the procedure, while computed tomography (CT) was used for serial imagery workup at baseline, 3-, 12-, 24- and 36-month follow-up. RESULTS: Early mortality was 10% due to non-device-related reasons, and thus 36 patients were included in the follow-up consisting of 1285 patient-days and mean duration of 3.5 ± 0.5 years. On CT, clips were found to be stable, showing no secondary dislocation 36 months after surgery. No intracardial thrombi were seen, none of the LAA was reperfused and in regard to LAA stump, none of the patients demonstrated a residual neck >1 cm. Apart from one unrelated transient ischaemic attack (TIA) that occurred 2 years after surgery in a patient with carotid plaque, no other strokes and/or neurological events demonstrated in any of the studied patients during follow-up. CONCLUSION: This is the first prospective trial in which concomitant epicardial LAA occlusion using this novel epicardial LAA clip device is 100% effective, safe and durable in the long term. Closure of the LAA by epicardial clipping is applicable to all-comers regardless of LAA morphology. Minimal access epicardial LAA clip closure may become an interesting therapeutic option for patients in AF who are not amenable to anticoagulation and/or catheter closure. Further data are necessary to establish LAA occlusion as a true and viable therapy for stroke prevention. CLINICAL TRIAL REGISTRATION: The trial is registered at www.ClinicalTrials.gov, reference: NCT00567515

    Effect of reader experience on variability, evaluation time and accuracy of coronary plaque detection with computed tomography coronary angiography

    Full text link
    OBJECTIVE: To assess the effect of reader experience on variability, evaluation time and accuracy in the detection of coronary artery plaques with computed tomography coronary angiography (CTCA). METHODS: Three independent, blinded readers with three different experience levels twice labelled 50 retrospectively electrocardiography (ECG)-gated contrast-enhanced dual-source CTCA data sets (15 female, age 67.3 +/- 10.4 years, range 46-86 years) indicating the presence or absence of coronary plaques. The evaluation times for the readings were recorded. Intra- and interobserver variability expressed as kappa statistics and sensitivity, specificity, and negative and positive predictive values were calculated for plaque detection, with a consensus reading of the three readers taken as the standard of reference. A bootstrap method was applied in the statistical analysis to account for clustering. RESULTS: Significant correlations were found between reader experience and, respectively, evaluation times (r = -0.59, p < 0.05) and intraobserver variability (r = 0.73, p < 0.05). The evaluation time significantly differed among the readers (p < 0.05). The observer variability for plaque detection, compared with the consensus, varied between kappa = 0.582 and kappa = 0.802. Variability of plaque detection was significantly smaller (p < 0.05) and more accurate (p < 0.05) for the most experienced reader. CONCLUSION: Reader experience significantly correlated with observer variability, evaluation time and accuracy of coronary plaque detection at CTCA