322 research outputs found

    Model-based Data Fusion in Industrial Process Instrumentation

    Get PDF

    Biosensors based on SPR Imaging

    Get PDF
    Surface plasmon resonance (SPR) belongs to the most sensitive detection methods and has been used for more than 20 years to study a variety of chemical and biochemical sensor developments. Now, with the recent introduction of biochips, SPR as a label-free technology for monitoring biomolecular interactions is a promising technique for rapid and parallel detection. SPR imaging using fast optical array detectors permits simultaneous measurements across an array of immobilized molecules. SPR imaging provides excellent spatial resolution at the same sensitivity as classical SPR. These features make SPR imaging a promising detection technology for biochips

    Method to Control Multiple Segmented LLSM without Position Encoder

    Get PDF
    In recent years long stator linear synchronous motors (LLSM) started to replace the typical rotating to linear converters like belts, chains, screw systems, pulleys, disks and so on. With LLSM a lot of drawbacks in the machine concepts and design can be prevented. For long tracks, reducing reactive power and individual control of numerous moveable units, the track is segmented in several fed stator units. Because of the LLSM construction an operation with a physical position encoder is not desirable. For that reason position observers should be used instead. In this paper a method to control the multiple segmented LLSM without position encoder is proposed. The special behaviour during entrance and exit of one moveable unit in an active stator segment is described and the control concept via a master slave relationship is proposed. Experimental results are presented to demonstrate the performance and feasibility of the proposed method

    Relationship between Sustained Reductions in Plasma Lipid and Lipoprotein Concentrations with Apheresis and Plasma Levels and mRNA Expression of PTX3 and Plasma Levels of hsCRP in Patients with HyperLp(a)lipoproteinemia

    Get PDF
    The effect of lipoprotein apheresis (Direct Adsorption of Lipids, DALI) (LA) on plasma levels of pentraxin 3 (PTX3), an inflammatory marker that reflects coronary plaque vulnerability, and expression of PTX3 mRNA was evaluated in patients with hyperLp(a)lipoproteinemia and angiographically defined atherosclerosis/coronary artery disease. Eleven patients, aged 55 ± 9.3 years (mean ± SD), were enrolled in the study. PTX3 soluble protein levels in plasma were unchanged by 2 sessions of LA; however, a downregulation of mRNA expression for PTX3 was observed, starting with the first session of LA (p < 0.001). The observed reduction was progressively increased in the interval between the first and second LA sessions to achieve a maximum decrease by the end of the second session. A statistically significantly greater treatment-effect correlation was observed in patients undergoing weekly treatments, compared with those undergoing treatment every 15 days. A progressive reduction in plasma levels of C-reactive protein was also seen from the first session of LA, with a statistically significant linear correlation for treatment-effect in the change in plasma levels of this established inflammatory marker (R(2) = 0.99; p < 0.001). Our findings suggest that LA has anti-inflammatory and endothelium protective effects beyond its well-established efficacy in lowering apoB100-containing lipoproteins

    Quantification and Classification of Cortical Perfusion during Ischemic Strokes by Intraoperative Thermal Imaging

    Get PDF
    Thermal imaging is a non-invasive and marker-free approach for intraoperative measurements of small temperature variations. In this work, we demonstrate the abilities of active dynamic thermal imaging for analysis of tissue perfusion state in case of cerebral ischemia. For this purpose, a NaCl irrigation is applied to the exposed cortex during hemicraniectomy. The cortical temperature changes are measured by a thermal imaging system and the thermal signal is recognized by a novel machine learning framework. Subsequent tissue heating is then approximated by a double exponential function to estimate tissue temperature decay constants. These constants allow us to characterize tissue with respect to its dynamic thermal properties. Using a Gaussian mixture model we show the correlation of these estimated parameters with infarct demarcations of post-operative CT. This novel scheme yields a standardized representation of cortical thermodynamic properties and might guide further research regarding specific intraoperative diagnostics

    Analysis of riboflavin/ultraviolet a corneal cross-linking by molecular spectroscopy

    Get PDF
    Corneal cross-linking (CXL) with riboflavin and ultraviolet A light is a therapeutic procedure to restore the mechanical stability of corneal tissue. The treatment method is applied to pathological tissue, such as keratoconus and induces the formation of new cross-links. At present, the molecular mechanisms of induced cross-linking are still not known exactly. In this study, we investigated molecular alterations within porcine cornea tissue after treatment with riboflavin and ultraviolet A light by surface enhanced Raman spectroscopy (SERS). For that purpose, after CXL treatment a thin silver layer was vapor-deposited onto cornea flaps. To explore molecular alterations induced by the photochemical process hierarchical cluster analysis (HCA) was used. The detailed analysis of SERS spectra reveals that there is no general change in collagen secondary structure while modifications on amino acid side chains are the most dominant outcome. The formation of secondary and aromatic amine groups as well as methylene and carbonyl groups were observed. Even though successful cross-linking could not be registered in all treated samples, Raman signals of newly formed chemical groups are already present in riboflavin only treated corneas

    Spectral network based on component cells under the SOPHIA European project

    Get PDF
    In the frame of the European project SOPHIA, a spectral network based on component (also called isotypes) cells has been created. Among the members of this project, several spectral sensors based on component cells and collimating tubes, so-called spectroheliometers, were installed in the last years, allowing the collection of minute-resolution spectral data useful for CPV systems characterization across Europe. The use of spectroheliometers has been proved useful to establish the necessary spectral conditions to perform power rating of CPV modules and systems. If enough data in a given period of time is collected, ideally a year, it is possible to characterize spectrally the place where measurements are taken, in the same way that hours of annual irradiation can be estimated using a pyrheliometer

    Combining targeted and systematic prostate biopsy improves prostate cancer detection and correlation with the whole mount histopathology in biopsy naĂŻve and previous negative biopsy patients

    Get PDF
    OBJECTIVE: Guidelines for previous negative biopsy (PNB) cohorts with a suspicion of prostate cancer (PCa) after positive multiparametric (mp) magnetic-resonance-imaging (MRI) often favour the fusion-guided targeted prostate-biopsy (TB) only approach for Prostate Imaging-Reporting and Data System (PI-RADS) ≥3 lesions. However, recommendations lack direct biopsy performance comparison within biopsy naïve (BN) vs. PNB patients and its prognostication of the whole mount pathology report (WMPR), respectively. We suppose, that the combination of TB and concomitant TRUS-systematic biopsy (SB) improves the PCa detection rate of PI-RADS 2, 3, 4 or 5 lesions and the International Society of Urological Pathology (ISUP)-grade predictability of the WMPR in BN- and PNB patients. METHODS: Patients with suspicious mpMRI, elevated prostate-specific-antigen and/or abnormal digital rectal examination were included. All PI-RADS reports were intramurally reviewed for biopsy planning. We compared the PI-RADS score substratified TB, SB or combined approach (TB/SB) associated BN- and PNB-PCa detection rate. Furthermore, we assessed the ISUP-grade variability between biopsy cores and the WMPR. RESULTS: According to BN (n = 499) vs. PNB (n = 314) patients, clinically significant (cs) PCa was detected more frequently by the TB/SB approach (62 vs. 43%) than with the TB (54 vs. 34%) or SB (57 vs. 34%) (all p < 0.0001) alone. Furthermore, we observed that the TB/SB strategy detects a significantly higher number of csPCa within PI-RADS 3, 4 or 5 reports, both in BN and PNB men. In contrast, applied biopsy techniques were equally effective to detect csPCa within PI-RADS 2 lesions. In case of csPCa diagnosis the TB approach was more often false-negative in PNB patients (BN 11% vs. PNB 19%; p = 0.02). The TB/SB technique showed in general significantly less upgrading, whereas a higher agreement was only observed for the total and BN patient cohort. CONCLUSION: Despite csPCa is more frequently found in BN patients, the TB/SB method always detected a significantly higher number of csPCa within PI-RADS 3, 4 or 5 reports of our BN and PNB group. The TB/SB strategy predicts the ISUP-grade best in the total and BN cohort and in general shows the lowest upgrading rates, emphasizing its value not only in BN but also PNB patients
    • …
    corecore