496 research outputs found

    Assessment of the radiological impact of a decommissioning nuclear power plant in Italy

    Full text link
    The assessment of the radiological impact of a decommissioning Nuclear Power Plant is presented here through the results of an environmental monitoring survey carried out in the area surrounding the Garigliano Power Plant. The levels of radioactivity in soil, water, air and other environmental matrices are shown, in which {\alpha}, {\beta} and {\gamma} activity and {\gamma} equivalent dose rate are measured. Radioactivity levels of the samples from the Garigliano area are analyzed and then compared to those from a control zone situated more than 100 km away. Moreover, a comparison is made with a previous survey held in 2001. The analyses and comparisons show no significant alteration in the radiological characteristics of the area surroundings the plant, with an overall radioactivity depending mainly from the global fallout and natural sources.Comment: 13 pages, 6 figures, 2 table

    Assessment of the radiological impact of a decommissioning nuclear power plant in Italy

    Get PDF
    The assessment of the radiological impact of a decommissioning Nuclear Power Plant is presented here through the results of an environmental monitoring survey carried out in the area surrounding the Garigliano Power Plant. The levels of radioactivity in soil, water, air and other environmental matrices are shown, in which {\alpha}, {\beta} and {\gamma} activity and {\gamma} equivalent dose rate are measured. Radioactivity levels of the samples from the Garigliano area are analyzed and then compared to those from a control zone situated more than 100 km away. Moreover, a comparison is made with a previous survey held in 2001. The analyses and comparisons show no significant alteration in the radiological characteristics of the area surroundings the plant, with an overall radioactivity depending mainly from the global fallout and natural sources

    Understanding the dynamic momentum aperture of the Advanced Light Source

    Get PDF
    The lifetime of a light source with small emittance like the Advanced Light Source (ALS) is usually limited by the momentum acceptance of the ring. Large momentum acceptances are reached by providing enough RF voltage and by avoiding a degradation of the dynamic momentum aperture. At the ALS the size of the momentum acceptance depends strongly on the transverse dynamics. It is very sensitive to machine conditions such as the tunes and chromaticities since depending on those conditions the Touschek scattered particles explore different resonance regions in the phase space. In this paper we show that by using a single-turn ’pinger’ magnet together with turn-byturn beam position monitors (BPM) one can identify the cause of a reduction in momentum acceptance and take steps to improve the acceptance

    Symmetric achromatic low-beta collider interaction region design concept

    Full text link
    We present a new symmetry-based concept for an achromatic low-beta collider interaction region design. A specially-designed symmetric Chromaticity Compensation Block (CCB) induces an angle spread in the passing beam such that it cancels the chromatic kick of the final focusing quadrupoles. Two such CCBs placed symmetrically around an interaction point allow simultaneous compensation of the 1st-order chromaticities and chromatic beam smear at the IP without inducing significant 2nd-order aberrations to the particle trajectory. We first develop an analytic description of this approach and explicitly formulate 2nd-order aberration compensation conditions at the interaction point. The concept is next applied to develop an interaction region design for the ion collider ring of an electron-ion collider. We numerically evaluate performance of the design in terms of momentum acceptance and dynamic aperture. The advantages of the new concept are illustrated by comparing it to the conventional distributed-sextupole chromaticity compensation scheme.Comment: 12 pages, 17 figures, to be submitted to Phys. Rev. ST Accel. Beam

    Investigation of noise sources in the LTP interferometer S2-AEI-TN-3028

    No full text
    All breadboards for the LTP interferometer showed an extra noise term that was, until recently, not fully understood. In this report that noise term is investigated in detail. It turns out that it is caused by sidebands on the light. In our lab, these sidebands were caused by nonlinear mixing processes in the power amplifiers that drive the AOM, if electromagnetic interference at a frequency near the operating frequency (ca. 80 MHz) is picked up by the power amplifier. The disturbing nearby frequency is the frequency of the other AOM, with a difference of exactly f_het, causing multiple sidebands at integer multiples of f_het from the carrier. They appear as pairs with a phase relationship that corresponds to phase-modulation (PM). Experiments with a very different electrical setup (in Glasgow) also showed sidebands which demonstrates that they are not caused by peculiarities of the Hannover setup. While the effect of a pair of first-order PM sidebands cancels and causes no harm, only one of the second-order sidebands produces noise which cannot be cancelled by its second-order mirror image. Hence the second-order sidebands are the dominant noise source. Various strategies of mitigation are also investigated. The two most important ones, both of which are already implemented as baseline for the LTP interferometer, are (1) to reduce the sidebands by careful EMC design and dedicated testing, and (2) to stabilize the optical pathlength difference (OPD) between the two fibers with a Piezo device. The combination of these two measures will reduce this error term to insignificance. We have also investigated other noise sources such as laser amplitude noise and beam jitter noise. Laser amplitude noise does have an influence on the total performance of the interferometer. Using a laser amplitude stabilization (part of the baseline), its influence can also be sufficiently reduced. Contrary to earlier worries, we did not find a significant noise contribution from beam jitter noise in conjunction with quadrant photodiodes. As part of this investigation we have also developed a mathematical model for the sideband coupling that fully describes their effect and has been experimentally verified. Furthermore we have developed various numerical procedures to find correlations between auxiliary data streams (such as alignment signals) and the main interferometer output. They are useful for diagnostic purposes, but in general too complex to implement on LTP. Using only those procedures that are the baseline for the FM, the noise performance of the LTP EM interferometer in the lab is now well below its specifications at all frequencies, with remaining noise sources mainly driven by ground-based disturbances, such that we are confident that the LTP interferometer will perform well on orbit and will enable the detailed study of the behaviour and noise performance of the inertial sensor and DFACS systems, which indeed is the primary job of the interferometer. Comment of the Author: Version 1.2 2008/07/0

    Acute ischaemic hemispheric stroke is associated with impairment of reflex in addition to voluntary cough

    Full text link
    Cough function is impaired after stroke; this may be important for protection against chest infection. Reflex cough (RC) intensity indices have not been described after stroke. RC, voluntary cough (VC) and respiratory muscle strength were studied in patients within 2 weeks of hemispheric infarct. The null hypotheses were that patients with cortical hemisphere stroke would show the same results as healthy controls on: 1) objective indices of RC and VC intensity; and 2) respiratory muscle strength tests.Peak cough flow rate (PCFR) and gastric pressure (Pga) were measured during maximum VC and RC. Participants also underwent volitional and nonvolitional respiratory muscle testing. Nonvolitional expiratory muscle strength was assessed by measuring Pga increase after magnetic stimulation over the T10 nerve roots (twitch T10 Pga). Stroke severity was scored using the National Institutes of Health Stroke Scale (NIHSS; maximum = 31).18 patients (mean±SD age 62±15 yrs and NIHSS score 14±8) and 20 controls (56±16 yrs) participated. VC intensity was impaired in patients (PCFR 287±171 versus 497±122 L·min−1) as was VC Pga (98.5±61.6 versus 208.5±61.3 cmH2O; p<0.001 for both). RC PCFR was reduced in patients (204±111 versus 379±110 L·min−1; p<0.001), but RC Pga was not significantly different from that of controls (179.0±78.0 versus 208.0±77.4 cmH2O; p = 0.266). Patients exhibited impaired volitional respiratory muscle tests, but twitch T10 Pga was normal.VC and RC are both impaired in hemispheric stroke patients, despite preserved expiratory muscle strength. Cough coordination is probably cortically modulated and affected by hemispheric stroke
    • …
    corecore