    Electrode positions, transformation coordinates for ECG reconstruction from S-ICD vectors.

    Get PDF
    The article contains data pertaining to the reconstruction of an 8-lead ECG from 2 subcutaneous implantable cardioverter defibrillator vectors. The location of electrodes on the precordium required for the data collection are detailed; the flow chart for patient selection and exclusion is shown; the summary data of the root mean square error (RMSE) (in microvolts) and Pearson r for the ECG transformation all cases and the pearson correlation for all the leads measured and reconstructed leads are also shown. Detailed background, methodology and discussion can be found in the linked research article

    Biventricular pacemaker therapy improves exercise capacity in patients with non‐obstructive hypertrophic cardiomyopathy via augmented diastolic filling on exercise

    Get PDF
    Aims Treatment options for patients with non‐obstructive hypertrophic cardiomyopathy (HCM) are limited. We sought to determine whether biventricular (BiV) pacing improves exercise capacity in HCM patients, and whether this is via augmented diastolic filling. Methods and results Thirty‐one patients with symptomatic non‐obstructive HCM were enrolled. Following device implantation, patients underwent detailed assessment of exercise diastolic filling using radionuclide ventriculography in BiV and sham pacing modes. Patients then entered an 8‐month crossover study of BiV and sham pacing in random order, to assess the effect on exercise capacity [peak oxygen consumption (VO2)]. Patients were grouped on pre‐specified analysis according to whether left ventricular end‐diastolic volume increased (+LVEDV) or was unchanged/decreased (–LVEDV) with exercise at baseline. Twenty‐nine patients (20 male, mean age 55 years) completed the study. There were 14 +LVEDV patients and 15 –LVEDV patients. Baseline peak VO2 was lower in –LVEDV patients vs. +LVEDV patients (16.2 ± 0.9 vs. 19.9 ± 1.1 mL/kg/min, P = 0.04). BiV pacing significantly increased exercise ΔLVEDV (P = 0.004) and Δstroke volume (P = 0.008) in –LVEDV patients, but not in +LVEDV patients. Left ventricular ejection fraction and end‐systolic elastance did not increase with BiV pacing in either group. This translated into significantly greater improvements in exercise capacity (peak VO2 + 1.4 mL/kg/min, P = 0.03) and quality of life scores (P = 0.02) in –LVEDV patients during the crossover study. There was no effect on left ventricular mechanical dyssynchrony in either group. Conclusion Symptomatic patients with non‐obstructive HCM may benefit from BiV pacing via augmentation of diastolic filling on exercise rather than contractile improvement. This may be due to relief of diastolic ventricular interaction. Clinical Trial Registration: ClinicalTrials.gov NCT00504647

    Rationale and design of the randomized multicentre His Optimized Pacing Evaluated for Heart Failure (HOPE-HF) trial:HOPE HF Trial rationale and design

    Get PDF
    Aims In patients with heart failure and a pathologically prolonged PR interval, left ventricular (LV) filling can be improved by shortening atrioventricular delay using His‐bundle pacing. His‐bundle pacing delivers physiological ventricular activation and has been shown to improve acute haemodynamic function in this group of patients. In the HOPE‐HF (His Optimized Pacing Evaluated for Heart Failure) trial, we are investigating whether these acute haemodynamic improvements translate into improvements in exercise capacity and heart failure symptoms. Methods and results This multicentre, double‐blind, randomized, crossover study aims to randomize 160 patients with PR prolongation (≥200 ms), LV impairment (EF ≤ 40%), and either narrow QRS (≤140 ms) or right bundle branch block. All patients receive a cardiac device with leads positioned in the right atrium and the His bundle. Eligible patients also receive a defibrillator lead. Those not eligible for implantable cardioverter defibrillator have a backup pacing lead positioned in an LV branch of the coronary sinus. Patients are allocated in random order to 6 months of (i) haemodynamically optimized dual chamber His‐bundle pacing and (ii) backup pacing only, using the non‐His ventricular lead. The primary endpoint is change in exercise capacity assessed by peak oxygen uptake. Secondary endpoints include change in ejection fraction, quality of life scores, B‐type natriuretic peptide, daily patient activity levels, and safety and feasibility assessments of His‐bundle pacing. Conclusions Hope‐HF aims to determine whether correcting PR prolongation in patients with heart failure and narrow QRS or right bundle branch block using haemodynamically optimized dual chamber His‐bundle pacing improves exercise capacity and symptoms. We aim to complete recruitment by the end of 2018 and report in 2020

    When is an optimization not an optimization? Evaluation of clinical implications of information content (signal-to-noise ratio) in optimization of cardiac resynchronization therapy, and how to measure and maximize it

    Get PDF
    Impact of variability in the measured parameter is rarely considered in designing clinical protocols for optimization of atrioventricular (AV) or interventricular (VV) delay of cardiac resynchronization therapy (CRT). In this article, we approach this question quantitatively using mathematical simulation in which the true optimum is known and examine practical implications using some real measurements. We calculated the performance of any optimization process that selects the pacing setting which maximizes an underlying signal, such as flow or pressure, in the presence of overlying random variability (noise). If signal and noise are of equal size, for a 5-choice optimization (60, 100, 140, 180, 220 ms), replicate AV delay optima are rarely identical but rather scattered with a standard deviation of 45 ms. This scatter was overwhelmingly determined (ρ = −0.975, P < 0.001) by Information Content, \documentclass[12pt]{minimal} \usepackage{amsmath} \usepackage{wasysym} \usepackage{amsfonts} \usepackage{amssymb} \usepackage{amsbsy} \usepackage{mathrsfs} \usepackage{upgreek} \setlength{\oddsidemargin}{-69pt} \begin{document}SignalSignal+Noise {\frac{\text{Signal}}{{{\text{Signal}} + {\text{Noise}}}}} \end{document}, an expression of signal-to-noise ratio. Averaging multiple replicates improves information content. In real clinical data, at resting, heart rate information content is often only 0.2–0.3; elevated pacing rates can raise information content above 0.5. Low information content (e.g. <0.5) causes gross overestimation of optimization-induced increment in VTI, high false-positive appearance of change in optimum between visits and very wide confidence intervals of individual patient optimum. AV and VV optimization by selecting the setting showing maximum cardiac function can only be accurate if information content is high. Simple steps to reduce noise such as averaging multiple replicates, or to increase signal such as increasing heart rate, can improve information content, and therefore viability, of any optimization process

    Mechanical effects of left ventricular midwall fibrosis in non-ischemic cardiomyopathy

    Get PDF
    Background: Left ventricular (LV) mid-wall fibrosis (MWF), which occurs in about a quarter of patients with non-ischemic cardiomyopathy (NICM), is associated with high risk of pump failure. The mid LV wall is the site of circumferential myocardial fibers. We sought to determine the effect of MWF on LV myocardial mechanics. Methods: Patients with NICM (n = 116; age: 62.8 ± 13.2 years; 67 % male) underwent late gadolinium enhancement cardiovascular magnetic resonance (CMR) and were categorized according to the presence (+) or absence (-) of MWF. Feature tracking (FT) CMR was used to assess myocardial deformation. Results: Despite a similar LVEF (24.3 vs 27.5 %, p = 0.20), patients with MWF (32 [24 %]) had lower global circumferential strain (εcc: -6.6 % vs -9.4 %, P = 0.004), but similar longitudinal (εll: -7.6 % vs. -9.4 %, p = 0.053) and radial (εrr: 14.6 % vs. 17.8 % p = 0.18) strain. Compared with - MWF, + MWF was associated with reduced LV systolic, circumferential strain rate (-0.38 ± 0.1 vs -0.56 ± 0.3 s-1, p = 0.005) and peak LV twist (4.65 vs. 6.31°, p = 0.004), as well as rigid LV body rotation (64 % vs 28 %, P cc: 0.34 vs. 0.46 s-1; DSRll: 0.38 vs. 0.50s-1; DSRrr: -0.55 vs. -0.75 s-1; all

    In Heart Failure Patients with Left Bundle Branch Block Single Lead MultiSpot Left Ventricular Pacing Does Not Improve Acute Hemodynamic Response To Conventional Biventricular Pacing. A Multicenter Prospective, Interventional, Non-Randomized Study.

    Get PDF
    Introduction Recent efforts to increase CRT response by multiSPOT pacing (MSP) from multiple bipols on the same left ventricular lead are still inconclusive. Aim The Left Ventricular (LV) MultiSPOTpacing for CRT (iSPOT) study compared the acute hemodynamic response of MSP pacing by using 3 electrodes on a quadripolar lead compared with conventional biventricular pacing (BiV). Methods Patients with left bundle branch block (LBBB) underwent an acute hemodynamic study to determine the %change in LV+dP/dtmax from baseline atrial pacing compared to the following configurations: BiV pacing with the LV lead in a one of lateral veins, while pacing from the distal, mid, or proximal electrode and all 3 electrodes together (i.e. MSP). All measurements were repeated 4 times at 5 different atrioventricular delays. We also measured QRS-width and individual Q-LV durations. Results Protocol was completed in 24 patients, all with LBBB (QRS width 171±20 ms) and 58% ischemic aetiology. The percentage change in LV+dP/dtmax for MSP pacing was 31.0±3.3% (Mean±SE), which was not significantly superior to any BiV pacing configuration: 28.9±3.2% (LV-distal), 28.3±2.7% (LV-mid), and 29.5±3.0% (LV-prox), respectively. Correlation between LV+dP/dtmax and either QRS-width or Q-LV ratio was poor. Conclusions In patients with LBBB MultiSPOT LV pacing demonstrated comparable improvement in contractility to best conventional BiV pacing. Optimization of atrioventricular delay is important for the best performance for both BiV and MultiSPOT pacing configurations. Trial Registration ClinicalTrials.gov NTC0188314

    Electrical modalities beyond pacing for the treatment of heart failure

    Get PDF
    In this review, we report on electrical modalities, which do not fit the definition of pacemaker, but increase cardiac performance either by direct application to the heart (e.g., post-extrasystolic potentiation or non-excitatory stimulation) or indirectly through activation of the nervous system (e.g., vagal or sympathetic activation). The physiological background of the possible mechanisms of these electrical modalities and their potential application to treat heart failure are discussed