802 research outputs found

    THE EFFECTS OF FIELD EMITTED ELECTRONS ON RF SURFACE

    Get PDF
    The ever-growing demand for higher RF gradients has considerably increased the risk of breakdown in accelerating structures. Field emission is the most common form of RF breakdown that generates free electrons capable of inflicting irreversible damages on the RF surface. This paper presents a systematic experimental and simulation programme to understand possible sources and their influence on RF cavity operatio

    Flow rate accuracy of infusion devices within healthcare settings: a systematic review

    Get PDF
    Background: One in five patients admitted to the hospital treated with intravenous (IV) fluid therapy suffer complications due to inappropriate administration. Errors have been reported in 13-84% of the preparation and administration of IV medications. The safe delivery of IV fluids requires precise rate administration. Objectives: This systematic review aims to determine the accuracy of infusion sets and devices and examine the factors that affect the flow rate accuracy of devices. Data sources and methods: Six databases (CINAHL, MEDLINE PubMed, EMBASE, Web of Science and Cochrane Database of systematic reviews) were systematically searched. Search terms included infusion pumps, infusion devices, flow rate accuracy, fluid administration rate, gravity-led infusion set and fluid balance. Studies were included if they examined infusion devices' flow rate accuracy and drop rates for fluids or non-oncological drugs. Findings were tabulated and synthesised qualitatively. The quality of the studies was examined based on the design of the studies due to their heterogeneity. Results: Eight studies were included: Four studies were conducted on human subjects in the hospital environment; studies recruited 182 participants between the ages of 18 and 94 years. Two studies examined flow rate accuracy in recruited patients across 509 observations and 2387 drip hours. No trials prospectively assessed the accuracy of infusion pumps in the clinical domain, and no studies were reported on patient safety outcomes. Four studies examined the impact of mechanical and physiological factors on the flow rate accuracies of infusion devices. Height and back pressure simulated vibrating conditions, the viscosity of IV fluid and the positions of patients were reported to have a significant impact on infusion volume and flow rates of infusion devices. Additionally, giving sets that vary from the manufacturer's specifications are reported to increase error percent by 10-20%. Conclusion: Infusion devices are an important source of error in administering IV fluids. Yet, there needs to be more prospective trial data to support their clinical accuracy and the impact on patient outcomes. Future flow variability and accuracy studies should capture their impact on patient safety and clinical outcomes

    SAFE: A System for Extraction and Retrieval of Semantic Audio Descriptors

    Get PDF
    date-added: 2014-08-02 10:04:50 +0000 date-modified: 2014-11-26 17:42:49 +0000 keywords: semantic audio, VST plugins, data collection, ISMIR demoIn this paper, we present an overview of the Semantic Audio Feature Extraction (SAFE) Project, a system for the extraction and retrieval of semantic descriptions of musical timbre, deployed within the digital audio workstation. By embedding the data capture system into the music production workflow, we are able to maximise the return of semantically annotated music production data, whilst mit- igating against issues such as musical and environmental bias. Users of the plugins are free to submit semantic de- scriptions of their own music, whilst utilising the continually growing collaborative dataset of musical descriptors. In order to provide more contextually representative timbral transformations, the dataset is partitioned using metadata, captured within the application

    Five cases and five unusual indications for autogenic renal transplantation

    Get PDF
    Five cases of renal autotransplantation representing five different indications for the procedure are presented and discussed

    Arteriography during ex vivo renal perfusion A complication

    Get PDF
    A case of bilateral renal-cell carcinoma unsuccessfully treated with bench surgery is reported. The reason for failure was apparently the toxicity of the contrast media used during the ex vivo arteriographic studies. © 1973

    Website design: Technical, social and medical issues for self-reporting by elderly patients

    Get PDF
    There is growing interest in the use of the Internet for interacting with patients, both in terms of healthcare information provision and information gathering. In this paper we examine the issues in designing healthcare websites for elderly users. In particular this paper uses a year-long case study of the development of a web-based system for self-reporting of symptoms and quality of life with a view to examine the issues relating to website design for elderly users. The issues identified included the technical, social and medical aspects of website design for elderly users. The web-based system developed was based upon the EQ5D health-status questionnaire, a commonly used tool for patient self-reporting of quality of life, and the more specific CROQ (coronary revascularisation outcome questionnaire) questionnaire. Currently self-reporting is generally administered in the form of paper-based questionnaires to be completed in the out-patient clinic, or at home. There are a variety of issues relating to elderly users that imply that websites for elderly patients may involve different design considerations to other types of websites

    Allocating Unique Property Reference Numbers to Patient Addresses Using A Deterministic Address-Matching Algorithm: Evaluation of Accuracy, Match Rate and Bias

    Get PDF
    Conference Proceedings from International Population Data Linkage Conference 202

    Investigating the prevalence, predictors, and prognosis of suboptimal statin use early after a non-ST elevation acute coronary syndrome

    Get PDF
    BACKGROUND:High-potency statin therapy is recommended in the secondary prevention of car-diovascular disease but discontinuation, dose reduction, statin switching, and/or nonadherence occurin practice.OBJECTIVES:To determine the prevalence and predictors of deviation from high-potency statin useearly after a non-ST elevation acute coronary syndrome (NSTE-ACS) and its association with subse-quent major adverse cardiovascular events (MACE) and all-cause mortality (ACM).METHODS:A total of 1005 patients from a UK-based prospective NSTE-ACS cohort study dis-charged on high-potency statin therapy (atorvastatin 80 mg, rosuvastatin 20 mg, or 40 mg daily)were included. At 1 month, patients were divided into constant high-potency statin users, and subop-timal users incorporating statin discontinuation, dose reduction, switching statin to a lower equivalentpotency, and/or statin nonadherence. Follow-up was a median of 16 months.RESULTS:There were 156 suboptimal (w15.5%) and 849 constant statin users. Factors associatedin multivariable analysis with suboptimal statin occurrence included female sex (odds ratio 1.75, 95%confidence interval [CI] 1.14–2.68) and muscular symptoms (odds ratio 4.28, 95% CI 1.30–14.08).Suboptimal statin use was associated with increased adjusted risks of time to MACE (hazard ratio2.10, 95% CI 1.25–3.53,P5.005) and ACM (hazard ratio 2.46, 95% CI 1.38–4.39,P5.003). Sub-group analysis confirmed that the increased MACE/ACM risks were principally attributable to statindiscontinuation or nonadherence.CONCLUSIONS:Conversion to suboptimal statin use is common early after NSTE-ACS and ispartly related to muscular symptoms. Statin discontinuation or non-adherence carries an adverse prog-nosis. Interventions that preserve and enhance statin utilization could improve post NSTE-ACSoutcomes
    • …
    corecore