1,680 research outputs found

    From vertex detectors to inner trackers with CMOS pixel sensors

    Full text link
    The use of CMOS Pixel Sensors (CPS) for high resolution and low material vertex detectors has been validated with the 2014 and 2015 physics runs of the STAR-PXL detector at RHIC/BNL. This opens the door to the use of CPS for inner tracking devices, with 10-100 times larger sensitive area, which require therefore a sensor design privileging power saving, response uniformity and robustness. The 350 nm CMOS technology used for the STAR-PXL sensors was considered as too poorly suited to upcoming applications like the upgraded ALICE Inner Tracking System (ITS), which requires sensors with one order of magnitude improvement on readout speed and improved radiation tolerance. This triggered the exploration of a deeper sub-micron CMOS technology, Tower-Jazz 180 nm, for the design of a CPS well adapted for the new ALICE-ITS running conditions. This paper reports the R&D results for the conception of a CPS well adapted for the ALICE-ITS.Comment: 4 pages, 4 figures, VCI 2016 conference proceeding

    A multidisciplinary expert opinion on CINV and RINV, unmet needs and practical real-life approaches

    Get PDF
    Introduction: A range of combination chemotherapy regimens are currently used in clinical practice. However, international antiemetic guidelines often only categorize the emetogenic potential of single agents rather than the emetogenicity of combination chemotherapy regimens. To manage the nausea and vomiting induced by antineoplastic combinations, guidelines suggest antiemetics that are appropriate for the component drug with the highest emetogenic potential. Furthermore, antiemetic guidelines generally do not consider the influence of other factors, including individual patient characteristics, on the emetic effects of cancer treatments. Similarly, the emetogenic potential of radiotherapy is stratified only according to the site of radiation, while other factors contributing to emetic risk are overlooked. Areas covered: An Expert Panel was convened to examine unresolved issues and summarize the current clinical research on managing nausea and vomiting associated with combination chemotherapy and radiotherapy. Expert opinion: The panel identified the incidence of nausea and vomiting induced by multi-drug combination therapies currently used to treat cancer at different anatomic sites and by radiotherapy in the presence of other risk factors. Based on these data and the clinical experience of panel members, several suggestions are made for a practical approach to prevent or manage nausea and vomiting due to chemotherapy regimens and radiation therapy

    Characterization and Performance of PADME's Cherenkov-Based Small-Angle Calorimeter

    Full text link
    The PADME experiment, at the Laboratori Nazionali di Frascati (LNF), in Italy, will search for invisible decays of the hypothetical dark photon via the process e+eγAe^+e^-\rightarrow \gamma A', where the AA' escapes detection. The dark photon mass range sensitivity in a first phase will be 1 to 24 MeV. We report here on measurement and simulation studies of the performance of the Small-Angle Calorimeter, a component of PADME's detector dedicated to rejecting 2- and 3-gamma backgrounds. The crucial requirement is a timing resolution of less than 200 ps, which is satisfied by the choice of PbF2_2 crystals and the newly released Hamamatsu R13478UV photomultiplier tubes (PMTs). We find a timing resolution of 81 ps (with double-peak separation resolution of 1.8 ns) and a single-crystal energy resolution of 5.7%/E\sqrt{E} with light yield of 2.07 photo-electrons per MeV, using 100 to 400 MeV electrons at the Beam Test Facility of LNF. We also propose the investigation of a two-PMT solution coupled to a single PbF2_2 crystal for higher-energy applications, which has potentially attractive features.Comment: 12 pages, 19 figures. v2: added section on radiation damage studie

    Sequential valproic acid/all-trans retinoic acid treatment reprograms differentiation in refractory and high risk acute myeloid leukemia.

    Get PDF
    Epigenetic alterations of chromatin due to aberrant histone deacetylase (HDAC) activity and transcriptional silencing of all-trans retinoic acid (ATRA) pathway are events linked to the pathogenesis of acute myeloid leukemia (AML) that can be targeted by specific treatments. A pilot study was carried out in eight refractory or high-risk AML patients not eligible for intensive therapy to assess the biological and therapeutic activities of the HDAC inhibitor valproic acid (VPA) used to remodel chromatin, followed by the addition of ATRA, to activate gene transcription and differentiation in leukemic cells. Hyperacetylation of histones H3 and H4 was detectable at therapeutic VPA serum levels (>or=50 microg/mL) in blood mononuclear cells from seven of eight patients. This correlated with myelomonocytic differentiation of leukemic cells as revealed by morphologic, cytochemical, immunophenotypic, and gene expression analyses. Differentiation of the leukemic clone was proven by fluorescence in situ hybridization analysis showing the cytogenetic lesion +8 or 7q- in differentiating cells. Hematologic improvement, according to established criteria for myelodysplastic syndromes, was observed in two cases. Stable disease and disease progression were observed in five and one cases, respectively. In conclusion, VPA-ATRA treatment is well tolerated and induces phenotypic changes of AML blasts through chromatin remodeling. Further studies are needed to evaluate whether VPA-ATRA treatment by reprogramming differentiation of the leukemic clone might improve the response to chemotherapy in leukemia patients

    Measurement of hadronic cross section and preliminary results on the pion form factor using the radiative return at DAPHNE

    Get PDF
    In the fixed energy environment of the e+ee^{+}e^{-} collider DAΦ\PhiNE, KLOE can measure the cross section of the process e+ee^{+}e^{-} \to hadrons as a function of the hadronic system energy using the radiative return. At energies below 1 GeV, e+eρπ+πe^{+}e^{-} \to \rho \to \pi^{+}\pi^{-} is the dominating hadronic process. We report here on the status of the analysis for the e^{+}e^{-} \to \ppg channel, which allows to obtain a preliminary measurement of the pion form factor using an integrated luminosity of 73pb1\sim73 pb^{-1}.Comment: Invited talk at the Seventh International Workshop on Tau Lepton Physics (TAU02-WE07), Santa Cruz, Ca, USA, Sept 2002, 9 pages, LaTeX, 9 eps figure

    Measurement of the leptonic decay widths of the phi-meson with the KLOE detector

    Full text link
    The phi-meson leptonic widths, Gee and Gmm, are obtained, respectively, from the e+e- forward-backward asymmetry and the muon cross section around the phi-mass energy. We find Gee=1.32⊕0.05⊕0.03 kev and sqrt(GeeGmm)= 1.320⊕0.018⊕0.017 kev. These results, compatible with Gee=Gmm, provide a precise test of lepton universality. Combining the two results gives G_lept=1.320⊕0.023 kev.Comment: 10 pages and 8 figures to be submitted to Phys.Lett.

    Measurement of the ratio Gamma(K_L -> gamma gamma)/Gamma(K_L -> pi^0 pi^0 pi^0) with the KLOE detector

    Get PDF
    We have measured the ratio R=Gamma(K_L -> gamma gamma)/ \Gamma(K_L -> 3 pi^0) using the KLOE detector. From a sample of ~ 10^9 phi-mesons produced at DAFNE, the Frascati phi-factory, we select ~ 1.6 10^8 K_L-mesons tagged by observing K_S -> pi^+ pi^- following the reaction e^+ e^- -> phi -> K_L K_S. From this sample we select 27,375 K_L -> gamma gamma events and obtain R = (2.79 \pm 0.02_{stat} \pm 0.02_{syst}) \times 10^{-3}. Using the world average value for BR(K_{L} -> 3 pi^0), we obtain BR(K_{L} -> gamma gamma) = (5.89 \pm 0.07 \pm 0.08) \times 10^{-4} where the second error is due to the uncertainty on the 3 pi^0 branching fraction.Comment: 14 page

    Upper Limit on the eta to gamma gamma gamma Branching Ratio with the KLOE Detector

    Get PDF
    We have searched for the C-violating decay eta to gamma gamma gamma in a sample of ~ 18 million eta mesons produced in phi to eta gamma decays, collected with the KLOE detector at the Frascati phi-factory DAFNE. No signal is observed and we obtain the upper limit BR(eta to gamma gamma gamma) less equal than 1.6x10^(-5) at 90 % C.L.Comment: 8 pages, 5 figures Systematic study refined, some figures reordere

    Measuring the hadronic cross section via radiative return

    Get PDF
    Recently it has been demonstrated that particle factories, such as DAPHNE and PEP-II, operating at fixed center-of-mass energies, are able to measure hadronic cross sections as a function of the hadronic system energy using the raditive return. This paper is an experimental overview of the progress in this aera. Preliminary results from KLOE for the process e+e- -> \rho \gamma -> \pi+\pi-\gamma and a fit to the pion form factor are presented. Some first results from the BABAR collaboration are also shown.Comment: Invited talk presented at RADCOR/Loops and Legs 2002, Kloster Banz/Germany, September 8-13 2002, 6 pages, 2 Figures; v1: references added, typos correcte
    corecore