1,865 research outputs found
From vertex detectors to inner trackers with CMOS pixel sensors
The use of CMOS Pixel Sensors (CPS) for high resolution and low material
vertex detectors has been validated with the 2014 and 2015 physics runs of the
STAR-PXL detector at RHIC/BNL. This opens the door to the use of CPS for inner
tracking devices, with 10-100 times larger sensitive area, which require
therefore a sensor design privileging power saving, response uniformity and
robustness. The 350 nm CMOS technology used for the STAR-PXL sensors was
considered as too poorly suited to upcoming applications like the upgraded
ALICE Inner Tracking System (ITS), which requires sensors with one order of
magnitude improvement on readout speed and improved radiation tolerance. This
triggered the exploration of a deeper sub-micron CMOS technology, Tower-Jazz
180 nm, for the design of a CPS well adapted for the new ALICE-ITS running
conditions. This paper reports the R&D results for the conception of a CPS well
adapted for the ALICE-ITS.Comment: 4 pages, 4 figures, VCI 2016 conference proceeding
Performance of the reconstruction algorithms of the FIRST experiment pixel sensors vertex detector
Hadrontherapy treatments use charged particles (e.g. protons and carbon ions) to treat tumors. During a therapeutic treatment with carbon ions, the beam undergoes nuclear fragmentation processes giving rise to significant yields of secondary charged particles. An accurate prediction of these production rates is necessary to estimate precisely the dose deposited into the tumours and the surrounding healthy tissues. Nowadays, a limited set of double differential carbon fragmentation cross-section is available. Experimental data are necessary to benchmark Monte Carlo simulations for their use in hadrontherapy. The purpose of the FIRST experiment is to study nuclear fragmentation processes of ions with kinetic energy in the range from 100 to 1000 MeV/u. Tracks are reconstructed using information from a pixel silicon detector based on the CMOS technology. The performances achieved using this device for hadrontherapy purpose are discussed. For each reconstruction step (clustering, tracking and vertexing), different methods are implemented. The algorithm performances and the accuracy on reconstructed observables are evaluated on the basis of simulated and experimental data
Characterization and Performance of PADME's Cherenkov-Based Small-Angle Calorimeter
The PADME experiment, at the Laboratori Nazionali di Frascati (LNF), in
Italy, will search for invisible decays of the hypothetical dark photon via the
process , where the escapes detection. The
dark photon mass range sensitivity in a first phase will be 1 to 24 MeV. We
report here on measurement and simulation studies of the performance of the
Small-Angle Calorimeter, a component of PADME's detector dedicated to rejecting
2- and 3-gamma backgrounds. The crucial requirement is a timing resolution of
less than 200 ps, which is satisfied by the choice of PbF crystals and the
newly released Hamamatsu R13478UV photomultiplier tubes (PMTs). We find a
timing resolution of 81 ps (with double-peak separation resolution of 1.8 ns)
and a single-crystal energy resolution of 5.7%/ with light yield of
2.07 photo-electrons per MeV, using 100 to 400 MeV electrons at the Beam Test
Facility of LNF. We also propose the investigation of a two-PMT solution
coupled to a single PbF crystal for higher-energy applications, which has
potentially attractive features.Comment: 12 pages, 19 figures. v2: added section on radiation damage studie
Measuring the hadronic cross section via radiative return
Recently it has been demonstrated that particle factories, such as DAPHNE and
PEP-II, operating at fixed center-of-mass energies, are able to measure
hadronic cross sections as a function of the hadronic system energy using the
raditive return. This paper is an experimental overview of the progress in this
aera. Preliminary results from KLOE for the process e+e- -> \rho \gamma ->
\pi+\pi-\gamma and a fit to the pion form factor are presented. Some first
results from the BABAR collaboration are also shown.Comment: Invited talk presented at RADCOR/Loops and Legs 2002, Kloster
Banz/Germany, September 8-13 2002, 6 pages, 2 Figures; v1: references added,
typos correcte
Measurement of hadronic cross section and preliminary results on the pion form factor using the radiative return at DAPHNE
In the fixed energy environment of the collider DANE, KLOE
can measure the cross section of the process hadrons as a
function of the hadronic system energy using the radiative return. At energies
below 1 GeV, is the dominating
hadronic process. We report here on the status of the analysis for the
e^{+}e^{-} \to \ppg channel, which allows to obtain a preliminary measurement
of the pion form factor using an integrated luminosity of .Comment: Invited talk at the Seventh International Workshop on Tau Lepton
Physics (TAU02-WE07), Santa Cruz, Ca, USA, Sept 2002, 9 pages, LaTeX, 9 eps
figure
Upper Limit on the eta to gamma gamma gamma Branching Ratio with the KLOE Detector
We have searched for the C-violating decay eta to gamma gamma gamma in a
sample of ~ 18 million eta mesons produced in phi to eta gamma decays,
collected with the KLOE detector at the Frascati phi-factory DAFNE. No signal
is observed and we obtain the upper limit BR(eta to gamma gamma gamma) less
equal than 1.6x10^(-5) at 90 % C.L.Comment: 8 pages, 5 figures Systematic study refined, some figures reordere
Measurement of the branching fraction for the decay KS --> pi e nu
We present a measurement of the branching ratio BR(KS --> pi e nu) performed
using the KLOE detector. KS mesons are produced in the reaction e+ e- --> phi
--> KS KL at the DAFNE collider. In a sample of about 5 million KS-tagged
events we find 624 +- 30 semileptonic KS decays. Normalizing to the KS --> pi+
pi- count in the same data sample, we obtain BR(KS --> pi e nu) = (6.91 +-
0.37) 10^-4, in agreement with the Standard Model expectation.Comment: 9 pages, 5 Encapsulated Postscript figures. Submitted to Phys. Lett.
Measurement of Gamma(phi -> eta' gamma)/Gamma(phi -> eta gamma) and the pseudoscalar mixing angle
We have measured the radiative decays phi -> eta gamma, phi ->etaprime gamma
selecting pi+ pi- gamma gamma gamma final state in a sample of about 5 times
10^7 phi mesons produced at the Frascati phi factory DAFNE. We obtain Gamma(phi
-> etaprime gamma)/Gamma(phi -> eta gamma)=(4.70 +- 0.47 +- 0.31) times 10^-3.
From this result we derive new accurate values for the branching ratio BR(phi
->etaprime gamma) = (6.10 +- 0.61 +- 0.43) times 10^-5, and the mixing angle of
pseudoscalar mesons in the flavour basis phi_P=(41.8 +1.9 -1.6) degrees.Comment: Submitted to Phys. Lett.
Study of the Decay phi --> eta pi0 gamma with the KLOE detector
In a sample of 5.3x10^7 phi-decays observed with the KLOE detector at the
Frascati phi-factory Dafne we find 605 eta pi0 gamma events with eta -->
gamma\gamma and 197 eta pi0 gamma events with eta --> pi+ pi- pi0. The decay
phi --> eta pi0 gamma is dominated by the process phi --> a0 gamma. From a fit
to the eta pi0 mass spectrum we find BR(phi --> ao(980) gamma)= (7.4 +-
0.7)x10^-5.Comment: 12 pages, 6 figures, submitted to Phys.Lett.
- …