237 research outputs found
Experimental demonstration of the stability of Berry's phase for a spin-1/2 particle
The geometric phase has been proposed as a candidate for noise resilient
coherent manipulation of fragile quantum systems. Since it is determined only
by the path of the quantum state, the presence of noise fluctuations affects
the geometric phase in a different way than the dynamical phase. We have
experimentally tested the robustness of Berry's geometric phase for spin-1/2
particles in a cyclically varying magnetic field. Using trapped polarized
ultra-cold neutrons it is demonstrated that the geometric phase contributions
to dephasing due to adiabatic field fluctuations vanish for long evolution
times.Comment: 4 pages, 4 figure
Improving the performance of aeroacoustic measurements beneath a turbulent boundary layer in a wake flow
Experimental measurement and subsequent numerical prediction of the excitation of at plates or car
windows beneath a turbulent boundary layer have become important for the development of novel cars and
airplanes. A wavenumber spectrum can be used to define the load on a plat caused by the pressure fluctuations on the surface. Wavenumber spectra from measurements are used to validate the numerical predictions of the acoustic and hydrodynamic portions of the pressure fluctuations. When measuring wavenumber spectra, the design of the experiment can have a large in fluence on the outcome. In this paper, the effects of both array design and the application of deconvolution algorithms on the experimental determination of the wavenumber-frequency spectrum are evaluated
An Improved Search for the Neutron Electric Dipole Moment
A permanent electric dipole moment of fundamental spin-1/2 particles violates
both parity (P) and time re- versal (T) symmetry, and hence, also charge-parity
(CP) symmetry since there is no sign of CPT-violation. The search for a neutron
electric dipole moment (nEDM) probes CP violation within and beyond the Stan-
dard Model. The experiment, set up at the Paul Scherrer Institute (PSI), an
improved, upgraded version of the apparatus which provided the current best
experimental limit, dn < 2.9E-26 ecm (90% C.L.), by the RAL/Sussex/ILL
collaboration: Baker et al., Phys. Rev. Lett. 97, 131801 (2006). In the next
two years we aim to improve the sensitivity of the apparatus to sigma(dn) =
2.6E-27 ecm corresponding to an upper limit of dn < 5E-27 ecm (95% C.L.), in
case for a null result. In parallel the collaboration works on the design of a
new apparatus to further increase the sensitivity to sigma(dn) = 2.6E-28 ecm.Comment: APS Division for particles and fields, Conference Proceedings, Two
figure
Diffraction of slow neutrons by holographic SiO_2 nanoparticle-polymer composite gratings
Diffraction experiments with holographic gratings recorded in SiO
nanoparticle-polymer composites have been carried out with slow neutrons. The
influence of parameters such as nanoparticle concentration, grating thickness
and grating spacing on the neutron-optical properties of such materials has
been tested. Decay of the grating structure along the sample depth due to
disturbance of the recording process becomes an issue at grating thicknesses of
about 100 microns and larger. This limits the achievable diffraction efficiency
for neutrons. As a solution to this problem, the Pendell\"{o}sung interference
effect in holographic gratings has been exploited to reach a diffraction
efficiency of 83% for very cold neutrons.Comment: 7 pages, 3 figures, submitted to Phys. Rev.
Synchronous Infra-Slow Oscillations Organize Ensembles of Accessory Olfactory Bulb Projection Neurons into Distinct Microcircuits
The accessory olfactory system controls social and sexual behavior. In the mouse accessory olfactory bulb, the first central stage of information processing along the accessory olfactory pathway, projection neurons (mitral cells) display infra-slow oscillatory discharge with remarkable periodicity. The physiological mechanisms that underlie this default output state, however, remain controversial. Moreover, whether such rhythmic infra-slow activity patterns exist in awake behaving mice and whether such activity reflects the functional organization of the accessory olfactory bulb circuitry remain unclear. Here, we hypothesize that mitral cell ensembles form synchronized microcircuits that subdivide the accessory olfactory bulb into segregated functional clusters. We use a miniature microscope to image the Ca2+ dynamics within the apical dendritic compartments of large mitral cell ensembles in vivo. We show that infra-slow periodic patterns of concerted neural activity, indeed, reflect the idle state of accessory olfactory bulb output in awake male and female mice. Ca2+ activity profiles are distinct and glomerulus-specific. Confocal time-lapse imaging in acute slices reveals that groups of mitral cells assemble into microcircuits that exhibit correlated Ca2+ signals. Moreover, electrophysiological profiling of synaptic connectivity indicates functional coupling between mitral cells. Our results suggest that both intrinsically rhythmogenic neurons and neurons entrained by fast synaptic drive are key elements in organizing the accessory olfactory bulb into functional microcircuits, each characterized by a distinct default pattern of infra-slow rhythmicity
Diffuse reflection of ultracold neutrons from low-roughness surfaces
We report a measurement of the reflection of ultracold neutrons from flat, large-area plates of different Fermi potential materials with low surface roughness. The results were used to test two diffuse reflection models, the well-known Lambert model and the micro-roughness model which is based on wave scattering. The Lambert model fails to reproduce the diffuse reflection data. The surface roughness b and correlation length w , obtained by fitting the micro-roughness model to the data are in the range 1 b 3 nm and 10 w 120 nm, in qualitative agreement with independent measurements using atomic force microscop
Gravitational depolarization of ultracold neutrons: comparison with data
We compare the expected effects of so-called gravitationally enhanced depolarization of ultracold neutrons to measurements carried out in a spin-precession chamber exposed to a variety of vertical magnetic-field gradients. In particular, we have investigated the dependence upon these field gradients of spin-depolarization rates and also of shifts in the measured neutron Larmor precession frequency. We find excellent qualitative agreement, with gravitationally enhanced depolarization accounting for several previously unexplained features in the data
Sensory Measurements: Coordination and Standardization
Do sensory measurements deserve the label of “measurement”? We argue that they do. They fit with an epistemological view of measurement held in current philosophy of science, and they face the same kinds of epistemological challenges as physical measurements do: the problem of coordination and the problem of standardization. These problems are addressed through the process of “epistemic iteration,” for all measurements. We also argue for distinguishing the problem of standardization from the problem of coordination. To exemplify our claims, we draw on olfactory performance tests, especially studies linking olfactory decline to neurodegenerative disorders
An Improved Neutron Electric Dipole Moment Experiment
A new measurement of the neutron EDM, using Ramsey's method of separated
oscillatory fields, is in preparation at the new high intensity source of
ultra-cold neutrons (UCN) at the Paul Scherrer Institute, Villigen, Switzerland
(PSI). The existence of a non-zero nEDM would violate both parity and time
reversal symmetry and, given the CPT theorem, might lead to a discovery of new
CP violating mechanisms. Already the current upper limit for the nEDM
(|d_n|<2.9E-26 e.cm) constrains some extensions of the Standard Model.
The new experiment aims at a two orders of magnitude reduction of the
experimental uncertainty, to be achieved mainly by (1) the higher UCN flux
provided by the new PSI source, (2) better magnetic field control with improved
magnetometry and (3) a double chamber configuration with opposite electric
field directions.
The first stage of the experiment will use an upgrade of the RAL/Sussex/ILL
group's apparatus (which has produced the current best result) moved from
Institut Laue-Langevin to PSI. The final accuracy will be achieved in a further
step with a new spectrometer, presently in the design phase.Comment: Flavor Physics & CP Violation Conference, Taipei, 200
- …