225 research outputs found

    Electrified hydraulic power steering system in hybrid electric heavy trucks

    Get PDF
    Over the last 20 years, conventional automotive engine ancillaries have migrated from being mechanically powered to electrically powered in order to meet market demand. To adopt this trend in heavy trucks requires a higher power electrical system in order to cope with the higher loads placed upon it. Until the advent of the hybrid electric heavy truck (HET) this power infrastructure has not been available. HET's require a higher voltage system in order to reduce losses and provide adequate power and voltage levels for the traction motor. This study investigates for the first time the benefit of electrifying a hydraulic power assisted steering system in an HET. The developed electrical hydraulic power steering (EHPS), using a high-voltage traction battery, is found to drastically reduce the consumed energy over a drive cycle by optimal operation of the pump over the driving cycle. Empirical data from a prototype HET with EHPS confirms the simulation results from Dymola

    Electromagnetic Analysis of a Synchronous Reluctance Motor With Single-Tooth Windings

    Full text link

    Simplified Automatic Fault Detection in Wind Turbine Induction Generators

    Get PDF
    This paper presents a simplified automated fault detection scheme for wind turbine induction generators with rotor electrical asymmetries. Fault indicators developed in previous works have made use of the presence of significant spectral peaks in the upper sidebands of the supply frequency harmonics; however, the specific location of these peaks may shift depending on the wind turbine speed. As wind turbines tend to operate under variable speed conditions, it may be difficult to predict where these fault‐related peaks will occur. To accommodate for variable speeds and resulting shifting frequency peak locations, previous works have introduced methods to identify or track the relevant frequencies, which necessitates an additional set of processing algorithms to locate these fault‐related peaks prior to any fault analysis. In this work, a simplified method is proposed to instead bypass the issue of variable speed (and shifting frequency peaks) by introducing a set of bandpass filters that encompass the ranges in which the peaks are expected to occur. These filters are designed to capture the fault‐related spectral information to train a classifier for automatic fault detection, regardless of the specific location of the peaks. Initial experimental results show that this approach is robust against variable speeds and further shows good generalizability in being able to detect faults at speeds and conditions that were not presented during training. After training and tuning the proposed fault detection system, the system was tested on “unseen” data and yielded a high classification accuracy of 97.4%, demonstrating the efficacy of the proposed approach

    Validation of a non-contact technique for torque measurements in wind turbines using an enhanced transient FSV approach

    Get PDF
    In-service turbine monitoring is essential for maximizing the wind energy contribution to the global energy budget. Measurement of turbine shaft torque under transient wind conditions is fundamental to develop reliable condition monitoring techniques. Contact based measurements bring their own disadvantages and non-contactless measurements have many potential advantages. However, their performance needs to be validated against standard methods. This paper focuses on the development of an enhanced transient Feature Selective Validation (FSV) techniques to undertake this analysis with an emphasis on transient data processing. The nature of FSV makes it a natural technique to consider for this problem space. Open questions have existed as to how transients should be dealt with in FSV. This paper overcomes the limitations of previous approaches for step-function transient comparison and presents analytical methods to ensure the transient feature itself is considered, irrespective of how much pre- and post- transient data happens to be included

    HRTEM study of orthorhombic zirconia in MgO-PSZ

    Get PDF
    High-resolution transmission electron microscopy (HRTEM) was used to study the phase of orthorhombic ZrO2 formed in magnesia partially stabilized zirconia (MgO-PSZ) during HRTEM specimen preparation. Based on the three reported crystal structures of orthorhombic ZrO2, with the space groups Pbcm, Pbc2(1) and Pbca, here it is shown that orthorhombic ZrO2 formed in MgO-PSZ has the Pbcm structure

    Design and Validation of a Synchronous Reluctance Motor With Single Tooth Windings

    Get PDF
    This paper presents for the first time the analysis and experimental validation of a six-slot four-pole synchronous reluctance motor with nonoverlapping fractional slot-concentrated windings. The machine exhibits high torque density and efficiency due to its high fill factor coils with very short end windings, facilitated by a segmented stator and bobbin winding of the coils. These advantages are coupled with its inherent robustness and low cost. The topology is presented as a logical step forward in advancing synchronous reluctance machines that have been universally wound with a sinusoidally distributed winding. The paper presents the motor design, performance evaluation through finite element studies and validation of the electromagnetic model, and thermal specification through empirical testing. It is shown that high performance synchronous reluctance motors can be constructed with single tooth wound coils, but considerations must be given regarding torque quality and the d-q axis inductances

    Non-collinear magnetic structures: a possible cause for current induced switching

    Full text link
    Current induced switching in Co/Cu/Co trilayers is described in terms of ab-initio determined magnetic twisting energies and corresponding sheet resistances. In viewing the twisting energy as an energy flux the characteristic time thereof is evaluated by means of the Landau-Lifshitz-Gilbert equation using ab-initio parameters. The obtained switching times are in very good agreement with available experimental data. In terms of the calculated currents, scalar quantities since a classical Ohm's law is applied, critical currents needed to switch magnetic configurations from parallel to antiparallel and vice versa can unambiguously be defined. It is found that the magnetoresistance viewed as a function of the current is essentially determined by the twisting energy as a function of the relative angle between the orientations of the magnetization in the magnetic slabs, which in turn can also explain in particular cases the fact that after having switched off the current the system remains in the switched magnetic configuration. For all ab-initio type calculations the fully relativistic Screened Korringa-Kohn-Rostoker method and the corresponding Kubo-Greenwood equation in the context of density functional theory are applied.Comment: 20 pages, 4 tables and 15 figures, submitted to PR

    Increased activity of 6-phosphogluconate dehydrogenase and glucose-6-phosphate dehydrogenase in purified cell suspensions and single cells from the uterine cervix in cervical intraepithelial neoplasia.

    Get PDF
    The activities of 6-phosphogluconate dehydrogenase and glucose-6-phosphate dehydrogenase have been measured in squamous epithelial cells of the uterine cervix from normal patients and cases of cervical intraepithelial neoplasia (CIN). A biochemical cycling method, which uses only simple equipment and is suited to routine use and to automation, was applied to cells separated by gradient centrifugation. In addition, cells were examined cytochemically, and the intensity of staining in the cytoplasm of single whole cells was measured using computerised microcytospectrophotometry. Twenty per cent of cells in samples from normal patients (n=61) showed staining intensities above an extinction of 0.15 at 540 nm, compared to 71% of cases of CIN 1 (n=14), 91% of cases of CIN 2 (n=11) and 67% of cases of CIN 3 (n=15). The cytochemical data do not allow definitive distinctions to be made between different grades of CIN whereas the biochemical assay applied to cell lysates shows convincing differences between normal samples and cases of CIN. There are no false negatives for CIN 3 (n=14) and CIN 2 (n=10) and 11% false negatives for CIN 1 (n=9) and 14% of false positives for normal cases (n=21). The results of this preliminary study with reference to automation are discussed [corrected]

    Polymorphisms in cytochrome P450 2C19 enzyme and cessation of leflunomide in patients with rheumatoid arthritis

    Get PDF
    Extent: 9p.Introduction: Rational selection of disease modifying anti-rheumatic drugs in the treatment of rheumatoid arthritis (RA) has many potential advantages, including rapid disease control, reduced long-term disability and reduced overall cost to the healthcare system. Inter-individual genetic differences are particularly attractive as markers to predict efficacy and toxicity, as they can be determined rapidly prior to drug selection. The aims of this study, therefore, were to investigate the association between differences in genes associated with the metabolism, clearance and efficacy of leflunomide with its cessation in a group of rheumatoid arthritis patients who were treated with an intensive contemporary, treat-to-target approach. Methods: This retrospective cohort study identified all individuals who received leflunomide and were enrolled in the Early Arthritis inception cohort at the Royal Adelaide Hospital between 2001 and July 2011. Inclusion criteria were age (>18) and a diagnosis of rheumatoid arthritis. Patients were excluded if a DNA sample was not available, if they withdrew from the cohort or if clinical data were insufficient. Subjects were followed for 12 months or until either another disease modifying antirheumatic drug was added or leflunomide was ceased. The following single nucleotide polymorphisms (SNPs) were determined: CYP2C19*2 (rs4244285), CYP2C19*17 (rs12248560), ABCG2 421C>A (rs2231142), CYP1A2*1F (rs762551) and DHODH 19C>A (rs3213422). The effects of variables on cessation were assessed with Cox Proportional Hazard models. Results: Thirty-three of 78 (42.3%) patients ceased leflunomide due to side effects. A linear trend between cytochrome P450 2C19 (CYP2C19) phenotype and leflunomide cessation was observed, with poor and intermediate metabolizers ceasing more frequently (adjusted Hazard Ratio = 0.432 for each incremental change in phenotype, 95% CI 0.237 to 0.790, P = 0.006). Previously observed associations between cytochrome P450 1A2 (CYP1A2) and dihydro-orotate dehydrogenase (DHODH) genotype and toxicity were not apparent, but there was a trend for ATP-binding cassette sub-family G member 2 (ABCG2) genotype to be associated with cessation due to diarrhea. Conclusions: CYP2C19 phenotype was associated with cessation due to toxicity, and since CYP2C19 intermediate and poor metabolizers have lower teriflunomide concentrations, it is likely that they have a particularly poor risk:benefit ratio when using this drug.Michael D Wiese, Matthew Schnabl, Catherine O’Doherty, Llewellyn D Spargo, Michael J Sorich, Leslie G Cleland and Susanna M Proudma
    • 

    corecore