74 research outputs found

    Septic Mesenteric Venous Thrombophlebitis: A Rare Complication of Acute Appendicitis

    Get PDF
    Mesenteric venous thrombophlebitis represents a very rare complication of acute appendicitis. Based on the findings of a 45-year-old patient with mesenteric venous thrombophlebitis due to acute appendicitis, we herein describe the diagnostic difficulties and therapeutic options in this uncommon disease. The treatment in our case consisted of simple appendectomy and perioperative anticoagulation therapy

    Validation of putative reference genes for gene expression studies in human hepatocellular carcinoma using real-time quantitative RT-PCR

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Reference genes, which are often referred to as housekeeping genes are frequently used to normalize mRNA levels between different samples in quantitative reverse transcription polymerase chain reaction (qRT-PCR). The selection of reference genes is critical for gene expression studies because the expression of these genes may vary among tissues or cells and may change under certain circumstances. Here, a systematic evaluation of six putative reference genes for gene expression studies in human hepatocellular carcinoma (HCC) is presented.</p> <p>Methods</p> <p>Six genes, beta-2-microglobulin (<it>B2M</it>), glyceraldehyde-3-phosphate dehydrogenase (<it>GAPDH</it>), hydroxymethyl-bilane synthase (<it>HMBS</it>), hypoxanthine phosphoribosyl-transferase 1 (<it>HPRT1</it>), succinate dehydrogenase complex, subunit A (<it>SDHA</it>) and ubiquitin C (<it>UBC</it>), with distinct functional characteristics and expression patterns were evaluated by qRT-PCR. Inhibitory substances in RNA samples were quantitatively assessed and controlled using an external RNA control. The stability of selected reference genes was analyzed using both <it>geNorm </it>and <it>NormFinder </it>software.</p> <p>Results</p> <p><it>HMBS </it>and <it>GAPDH </it>were identified as the optimal reference genes for normalizing gene expression data between paired tumoral and adjacent non-tumoral tissues derived from patients with HCC. <it>HMBS, GAPDH </it>and <it>UBC </it>were identified to be suitable for the normalization of gene expression data among tumor tissues; whereas the combination of <it>HMBS, B2M</it>, <it>SDHA </it>and <it>GAPDH </it>was suitable for normalizing gene expression data among five liver cancer cell lines, namely Hep3B, HepG2, HuH7, SK-HEP-1 and SNU-182. The determined gene stability was increased after exclusion of RNA samples containing relatively higher inhibitory substances.</p> <p>Conclusion</p> <p>Of six genes studied, <it>HMBS </it>was found to be the single best reference gene for gene expression studies in HCC. The appropriate choice of combination of more than one reference gene to improve qRT-PCR accuracy depends on the kind of liver tissues or cells under investigation. Quantitative assessment and control of qRT-PCR inhibitors using an external RNA control can reduce the variation of qRT-PCR assay and facilitate the evaluation of gene stability. Our results may facilitate the choice of reference genes for expression studies in HCC.</p

    Transplantation of Renal Allografts From Organ Donors Reactive for HCV Antibodies to HCV-Negative Recipients: Safety and Clinical Outcome

    Get PDF
    IntroductionBecause of the shortage of available organs for renal transplantation, strategies enabling the safe use of organs from donors with potential chronic infections such as hepatitis C are necessary. The aim of this study was to analyze the outcome of renal transplant donation from hepatitis C virus (HCV)-positive donors.MethodsBetween September 2002 and May 2007, 51 kidneys (34 donors) reactive for HCV antibodies were further evaluated. Six kidneys (5 donors) were transplanted to 6 recipients with known chronic HCV infection. The remaining 29 donors underwent extended virological testing. Nine donors were HCV RNA positive and thus not suitable for HCV-negative patients. Twenty donors (21 kidneys) did not have detectable HCV RNA copies and were transplanted into 21 HCV-negative recipients. Clinical outcomes focusing on safety, allograft function, and de novo HCV infection in the recipient were collected.ResultsThere were no de novo HCV infections detected in recipients who were HCV negative before transplantation. The extended virological donor screening did not have an impact on median cold ischemia time. Five-year graft survival was 75%.DiscussionOrgans from anti-HCV-reactive, nonviremic donors can be transplanted safely to HCV-negative recipients

    Neurologic complications in adult living donor liver transplant patients: an underestimated factor?

    Get PDF
    Liver transplantation is the only curative treatment in patients with end-stage liver disease. Neurological complications (NC) are increasingly reported to occur in patients after cadaveric liver transplantation. This retrospective cohort study aims to evaluate the incidence and causes of NC in living donor liver transplant (LDLT) patients in our transplant center. Between August 1998 and December 2005, 121 adult LDLT patients were recruited into our study. 17% of patients experienced NC, and it occurred significantly more frequently in patients with alcoholic cirrhosis (42%) and autoimmune hepatitis (43%) as compared with patients with hepatitis B or C (9/10%, P = 0.013). The most common NC was encephalopathy (47.6%) followed by seizures (9.5%). The choice of immunosuppression by calcineurin inhibitor (Tacrolimus or Cyclosporin A) showed no significant difference in the incidence of NC (19 vs. 17%). The occurrence of NC did not influence the clinical outcome, since mortality rate, median ICU stay and length of hospital stay were similar between the two groups. Most patients who survived showed a nearly complete recovery of their NC. NCs occur in approximately 1 in 6 patients after LDLT and seem to be predominantly transient in nature, without major impact on clinical outcome

    Elevated expression of cyclooxygenase-2 is a negative prognostic factor for overall survival in intrahepatic cholangiocarcinoma

    Get PDF
    The production of prostaglandins is regulated by cyclooxygenases (COXs), which also have a role in tumour development and progression in various human malignancies, including cholangiocarcinoma. Limited information is available of the correlation of COX-2 protein expression and prognosis in intrahepatic cholangiocarcinoma (ICC). The aim of the present study was to determine the clinical significance of COX-2 expression in ICC. In addition the correlation of COX-2 expression and apoptosis/proliferation was analysed. COX-2 expression was determined immunohistochemically in 62 resected ICCs. Proliferation was assessed using Ki67-immunohistochemistry, and apoptosis was measured with the TdT-mediated dUTP nick-end-labelling technique. COX-2 was identified as an independent prognostic factor (P = 0.028) in resected ICC by survival analysis. High levels of COX-2 expression were found to be associated both with reduced apoptosis and increased proliferation of tumour cells. This study demonstrates the independent prognostic value of the COX-2 expression in resected ICC, thus, offering a potential additional adjuvant therapeutic approach with COX-2 inhibitors

    Performance of the CMS muon trigger system in proton-proton collisions at √s = 13 TeV

    Get PDF
    The muon trigger system of the CMS experiment uses a combination of hardware and software to identify events containing a muon. During Run 2 (covering 2015-2018) the LHC achieved instantaneous luminosities as high as 2 × 10 cm s while delivering proton-proton collisions at √s = 13 TeV. The challenge for the trigger system of the CMS experiment is to reduce the registered event rate from about 40 MHz to about 1 kHz. Significant improvements important for the success of the CMS physics program have been made to the muon trigger system via improved muon reconstruction and identification algorithms since the end of Run 1 and throughout the Run 2 data-taking period. The new algorithms maintain the acceptance of the muon triggers at the same or even lower rate throughout the data-taking period despite the increasing number of additional proton-proton interactions in each LHC bunch crossing. In this paper, the algorithms used in 2015 and 2016 and their improvements throughout 2017 and 2018 are described. Measurements of the CMS muon trigger performance for this data-taking period are presented, including efficiencies, transverse momentum resolution, trigger rates, and the purity of the selected muon sample. This paper focuses on the single- and double-muon triggers with the lowest sustainable transverse momentum thresholds used by CMS. The efficiency is measured in a transverse momentum range from 8 to several hundred GeV
    corecore