143 research outputs found

    Capillary electrophoresis-mass spectrometry using noncovalently coated capillaries for the analysis of biopharmaceuticals

    Get PDF
    In this work, the usefulness of capillary electrophoresis–electrospray ionization time-of-flight–mass spectrometry for the analysis of biopharmaceuticals was studied. Noncovalently bound capillary coatings consisting of Polybrene-poly(vinyl sulfonic acid) or Polybrene-dextran sulfate-Polybrene were used to minimize protein and peptide adsorption, and achieve good separation efficiencies. The potential of the capillary electrophoresis-mass spectrometry (CE-MS) system to characterize degradation products was investigated by analyzing samples of the drugs, recombinant human growth hormone (rhGH) and oxytocin, which had been subjected to prolonged storage, heat exposure, and/or different pH values. Modifications could be assigned based on accurate masses as obtained with time-of-flight–mass spectrometry (TOF-MS) and migration times with respect to the parent compound. For heat-exposed rhGH, oxidations, sulfonate formation, and deamidations were observed. Oxytocin showed strong deamidation (up to 40%) upon heat exposure at low pH, whereas at medium and high pH, mainly dimer (>10%) and trisulfide formation (6–7%) occurred. Recombinant human interferon-β-1a (rhIFN-β) was used to evaluate the capability of the CE-MS method to assess glycan heterogeneity of pharmaceutical proteins. Analysis of this N-glycosylated protein revealed a cluster of resolved peaks which appeared to be caused by at least ten glycoforms differing merely in sialic acid and hexose N-acetylhexosamine composition. Based on the relative peak area (assuming an equimolar response per glycoform), a quantitative profile could be derived with the disialytated biantennary glycoform as most abundant (52%). Such a profile may be useful for in-process and quality control of rhIFN-β batches. It is concluded that the separation power provided by combined capillary electrophoresis and TOF-MS allows discrimination of highly related protein species

    Profiling of a high mannose-type N-glycosylated lipase using hydrophilic interaction chromatography-mass spectrometry

    Get PDF
    Many industrial enzymes exhibit macro- and micro-heterogeneity due to co-occurring post-translational modifications. The resulting proteoforms may have different activity and stability and, therefore, the characterization of their distributions is of interest in the development and monitoring of enzyme products. Protein glycosylation may play a critical role as it can influence the expression, physical and biochemical properties of an enzyme. We report the use of hydrophilic interaction liquid chromatography-mass spectrometry (HILIC-MS) to profile intact glycoform distributions of high mannose-type N-glycosylated proteins, using an industrially produced fungal lipase for the food industry as an example. We compared these results with conventional reversed phase LC-MS (RPLC-MS) and sodium dodecyl sulfate-polyacrylamide gel-electrophoresis (SDS-PAGE). HILIC appeared superior in resolving lipase heterogeneity, facilitating mass assignment of N-glycoforms and sequence variants. In order to understand the glycoform selectivity provided by HILIC, fractions from the four main HILIC elution bands for lipase were taken and subjected to SDS-PAGE and bottom-up proteomic analysis. These analyses enabled the identification of the most abundant glycosylation sites present in each fraction and corroborated the capacity of HILIC to separate protein glycoforms based on the number of glycosylation sites occupied. Compared to RPLC-MS, HILIC-MS reducted the sample complexity delivered to the mass spectrometer, facilitating the assignment of the masses of glycoforms and sequence variants as well as increasing the number of glycoforms detected (69 more proteoforms, 177% increase). The HILIC-MS method required relatively short analysis time (<30 min), in which over 100 glycoforms were distinguished. We suggest that HILIC(-MS) can be a valuable tool in characterizing bioengineering processes aimed at steering protein glycoform expression as well as to check the consistency of product batche

    Anionic metabolic profiling of urine from antibiotic-treated rats by capillary electrophoresis-mass spectrometry

    Get PDF
    Abstract A recently developed capillary electrophoresis (CE)-negative-ionisation mass spectrometry (MS) method was used to profile anionic metabolites in a microbial-host co-metabolism study. Urine samples from rats receiving antibiotics (penicillin G and streptomycin sulfate) for 0, 4, or 8 days were analysed. A quality control sample was measured repeatedly to monitor the performance of the applied CE-MS method. After peak alignment, relative standard deviations (RSDs) for migration time of five representative compounds were below 0.4 %, whereas RSDs for peak area were 7.9-13.5 %. Using univariate and principal component analysis of obtained urinary metabolic profiles, groups of rats receiving different antibiotic treatment could be distinguished based on 17 discriminatory compounds, of which 15 were downregulated and 2 were upregulated upon treatment. Eleven compounds remained down-or upregulated after discontinuation of the antibiotics administration, whereas a recovery effect was observed for others. Based on accurate mass, nine compounds were putatively identified; these included the microbialmammalian co-metabolites hippuric acid and indoxyl sulfate. Some discriminatory compounds were also observed by other analytical techniques, but CE-MS uniquely revealed ten metabolites modulated by antibiotic exposure, including aconitic acid and an oxocholic acid. This clearly demonstrates the added value of CE-MS for nontargeted profiling of small anionic metabolites in biological samples

    Excitons in a Photosynthetic Light-Harvesting System: A Combined Molecular Dynamics/Quantum Chemistry and Polaron Model Study

    Get PDF
    The dynamics of pigment-pigment and pigment-protein interactions in light-harvesting complexes is studied with a novel approach which combines molecular dynamics (MD) simulations with quantum chemistry (QC) calculations. The MD simulations of an LH-II complex, solvated and embedded in a lipid bilayer at physiological conditions (with total system size of 87,055 atoms) revealed a pathway of a water molecule into the B800 binding site, as well as increased dimerization within the B850 BChl ring, as compared to the dimerization found for the crystal structure. The fluctuations of pigment (B850 BChl) excitation energies, as a function of time, were determined via ab initio QC calculations based on the geometries that emerged from the MD simulations. From the results of these calculations we constructed a time-dependent Hamiltonian of the B850 exciton system from which we determined the linear absorption spectrum. Finally, a polaron model is introduced to describe quantum mechanically both the excitonic and vibrational (phonon) degrees of freedom. The exciton-phonon coupling that enters into the polaron model, and the corresponding phonon spectral function are derived from the MD/QC simulations. It is demonstrated that, in the framework of the polaron model, the absorption spectrum of the B850 excitons can be calculated from the autocorrelation function of the excitation energies of individual BChls, which is readily available from the combined MD/QC simulations. The obtained result is in good agreement with the experimentally measured absorption spectrum.Comment: REVTeX3.1, 23 pages, 13 (EPS) figures included. A high quality PDF file of the paper is available at http://www.ks.uiuc.edu/Publications/Papers/PDF/DAMJ2001/DAMJ2001.pd

    Clinical performance and radiation dosimetry of no-carrier-added vs carrier-added 123I-metaiodobenzylguanidine (MIBG) for the assessment of cardiac sympathetic nerve activity

    Get PDF
    Purpose We hypothesized that assessment of myocardial sympathetic activity with no-carrier-added (nca) I-123-metaiodobenzylguanidine (MIBG) compared to carrier-added (ca) I-123-MIBG would lead to an improvement of clinical performance without major differences in radiation dosimetry. Methods In nine healthy volunteers, 15 min and 4 h planar thoracic scintigrams and conjugate whole-body scans were performed up to 48 h following intravenous injection of 185 MBq I-123-MIBG. The subjects were given both nca and ca I-123-MIBG. Early heart/mediastinal ratios (H/M), late H/M ratios and myocardial washout were calculated. The fraction of administered activity in ten source organs was quantified from the attenuation-corrected geometric mean counts in conjugate views. Radiation-absorbed doses were estimated with OLINDA/EXM software. Results Both early and late H/M were higher for nca I-123-MIBG (ca I-123-MIBG early H/M 2.46 +/- 0.15 vs nca I-123-MIBG 2.84 +/- 0.15, p = 0.001 and ca I-123-MIBG late H/M 2.69 +/- 0.14 vs nca I-123-MIBG 3.34 +/- 0.18, p = 0.002). Myocardial washout showed a longer retention time for nca I-123-MIBG (p <0.001). The effective dose equivalent (adult male model) for nca I-123-MIBG was similar to that for ca I-123-MIBG (0.025 +/- 0.002 mSv/MBq vs 0.026 +/- 0.002 mSv/MBq, p = 0.055, respectively). Conclusion No-carrier-added I-123-MIBG yields a higher relative myocardial uptake and is associated with a higher myocardial retention. This difference between nca I-123-MIBG and ca I-123-MIBG in myocardial uptake did not result in major differences in estimated absorbed doses. Therefore, nca I-123-MIBG is to be preferred over ca I-123-MIBG for the assessment of cardiac sympathetic activit

    Capillary electrophoresis-mass spectrometry analysis of trehalose-6-phosphate in Arabidopsis thaliana seedlings

    Get PDF
    Trehalose-6-phosphate (T6P) is an intermediate in the plant metabolic pathway that results in trehalose production. T6P has been shown to inhibit the sucrose nonfermenting-1-related protein kinase 1, which is a major regulator of metabolism. The quantitation of T6P has proven difficult due to the complexity of the plant matrix and the low abundance of T6P in plant tissues. The aim of this work was to develop a quantitation method for T6P present in Arabidopsis tissues, with capillary electrophoresis (CE) coupled to electrospray ionization-mass spectrometry (MS) with a sheath liquid (SL) interface. The CE-MS method was first optimized with respect to T6P signal intensity and separation of isomers by studying the composition of the background electrolyte (BGE) and SL. The use of triethylamine (TEA) in the BGE was favorable, providing separation of T6P from sucrose-6-phosphate and minimizing ionization suppression. Replacing ammonium acetate with TEA enhanced T6P signal intensities more than four times. The optimized method allowed quantification of T6P in plant extracts with good linearity (r2 > 0.99) within a biologically relevant concentration range. The limit of quantification was 80 nM in Arabidopsis extracts, corresponding to 33 pmol/g plant fresh weight. The CE-MS method was applied to the determination of T6P in seedlings from wild type (WT) Arabidopsis and mutants lacking the trehalase AtTRE1, tre1-1, challenged with trehalose or sorbitol. T6P accumulation in tre1-1 plants grown on sorbitol was about twice the level of T6P found in WT. CE-MS is shown to be a fast and reliable technique to analyze phosphodisaccharides for seedling extracts. The low sample volume requirement of CE and its direct MS coupling makes it an attractive alternative for anion-exchange liquid chromatography–MS

    Linear dichroism and circular dichroism in photosynthesis research

    Get PDF
    The efficiency of photosynthetic light energy conversion depends largely on the molecular architecture of the photosynthetic membranes. Linear- and circular-dichroism (LD and CD) studies have contributed significantly to our knowledge of the molecular organization of pigment systems at different levels of complexity, in pigment–protein complexes, supercomplexes, and their macroassemblies, as well as in entire membranes and membrane systems. Many examples show that LD and CD data are in good agreement with structural data; hence, these spectroscopic tools serve as the basis for linking the structure of photosynthetic pigment–protein complexes to steady-state and time-resolved spectroscopy. They are also indispensable for identifying conformations and interactions in native environments, and for monitoring reorganizations during photosynthetic functions, and are important in characterizing reconstituted and artificially constructed systems. This educational review explains, in simple terms, the basic physical principles, and theory and practice of LD and CD spectroscopies and of some related quantities in the areas of differential polarization spectroscopy and microscopy
    corecore