3 research outputs found

    Measurements and Modelling of Total Ozone Columns near St. Petersburg, Russia

    Get PDF
    The observed ozone layer depletion is influenced by continuous anthropogenic activity. This fact enforced the regular ozone monitoring globally. Information on spatial-temporal variations in total ozone columns (TOCs) derived by various observational methods and models can differ significantly due to measurement and modelling errors, differences in ozone retrieval algorithms, etc. Therefore, TOC data derived by different means should be validated regularly. In the current study, we compare TOC variations observed by ground-based (Bruker IFS 125 HR, Dobson, and M-124) and satellite (OMI, TROPOMI, and IKFS-2) instruments and simulated by models (ERA5 and EAC4 re-analysis, EMAC and INM RAS—RSHU models) near St. Petersburg (Russia) between 2009 and 2020. We demonstrate that TOC variations near St. Petersburg measured by different methods are in good agreement (with correlation coefficients of 0.95–0.99). Mean differences (MDs) and standard deviations of differences (SDDs) with respect to Dobson measurements constitute 0.0–3.9% and 2.3–3.7%, respectively, which is close to the actual requirements of the quality of TOC measurements. The largest bias is observed for Bruker 125 HR (3.9%) and IKFS-2 (−2.4%) measurements, whereas M-124 filter ozonometer shows no bias. The largest SDDs are observed for satellite measurements (3.3–3.7%), the smallest—for ground-based data (2.3–2.8%). The differences between simulated and Dobson data vary significantly. ERA5 and EAC4 re-analysis data show slight negative bias (0.1–0.2%) with SDDs of 3.7–3.9%. EMAC model overestimates Dobson TOCs by 4.5% with 4.5% SDDs, whereas INM RAS-RSHU model underestimates Dobson by 1.4% with 8.6% SDDs. All datasets demonstrate the pronounced TOC seasonal cycle with the maximum in spring and minimum in autumn. Finally, for 2004–2021 period, we derived a significant positive TOC trend near St. Petersburg (~0.4 ± 0.1 DU per year) from all datasets considered

    Measurements and Modelling of Total Ozone Columns near St. Petersburg, Russia

    No full text
    The observed ozone layer depletion is influenced by continuous anthropogenic activity. This fact enforced the regular ozone monitoring globally. Information on spatial-temporal variations in total ozone columns (TOCs) derived by various observational methods and models can differ significantly due to measurement and modelling errors, differences in ozone retrieval algorithms, etc. Therefore, TOC data derived by different means should be validated regularly. In the current study, we compare TOC variations observed by ground-based (Bruker IFS 125 HR, Dobson, and M-124) and satellite (OMI, TROPOMI, and IKFS-2) instruments and simulated by models (ERA5 and EAC4 re-analysis, EMAC and INM RAS-RSHU models) near St. Petersburg (Russia) between 2009 and 2020. We demonstrate that TOC variations near St. Petersburg measured by different methods are in good agreement (with correlation coefficients of 0.95-0.99). Mean differences (MDs) and standard deviations of differences (SDDs) with respect to Dobson measurements constitute 0.0-3.9% and 2.3-3.7%, respectively, which is close to the actual requirements of the quality of TOC measurements. The largest bias is observed for Bruker 125 HR (3.9%) and IKFS-2 (-2.4%) measurements, whereas M-124 filter ozonometer shows no bias. The largest SDDs are observed for satellite measurements (3.3-3.7%), the smallest-for ground-based data (2.3-2.8%). The differences between simulated and Dobson data vary significantly. ERA5 and EAC4 re-analysis data show slight negative bias (0.1-0.2%) with SDDs of 3.7-3.9%. EMAC model overestimates Dobson TOCs by 4.5% with 4.5% SDDs, whereas INM RAS-RSHU model underestimates Dobson by 1.4% with 8.6% SDDs. All datasets demonstrate the pronounced TOC seasonal cycle with the maximum in spring and minimum in autumn. Finally, for 2004-2021 period, we derived a significant positive TOC trend near St. Petersburg (similar to 0.4 +/- 0.1 DU per year) from all datasets considered.ISSN:2072-429

    An Unprecedented Arctic Ozone Depletion Event During Spring 2020 and its Impacts Across Europe

    No full text
    International audienceThe response of the ozone column across Europe to the extreme 2020 Arctic ozone depletion was examined by analysing ground-based observations at 38 European stations. The ozone decrease at the northernmost site, Ny-Ålesund (79°N) was about 43% with respect to a climatology of more than 30 years. The magnitude of the decrease declined by about 0.7 % deg-1 moving to south to reach nearly 15% at 40°N. In addition, it was found that the variations of the ozone column at each of the selected stations in March-May were similar to those observed at Ny-Ålesund but with a delay increasing to about 20 days at mid-latitudes with a gradient of approximately 0.5 days deg-1. The distributions of reconstructed ozone column anomalies over a sector covering a large European area show decreasing ozone that started from the north at the beginning of April 2020 and spread south. Such behaviour was shown to be similar to that observed after the Arctic ozone depletion in 2011. Stratospheric dynamical patterns in March to May 2011 and during 2020 suggested that the migration of ozone-poor air masses from polar areas to the south after the vortex breakup caused the observed ozone responses. A brief survey of the ozone mass mixing ratios at three stratospheric levels showed the exceptional strength of the 2020 episode. Despite the stronger and longer-lasting Arctic ozone loss in 2020, the analysis in this work indicates a similar ozone response at latitudes below 50°N to both 2011 and 2020 phenomena
    corecore