523 research outputs found

    Background analysis and status of the ANAIS dark matter project

    Full text link
    ANAIS (Annual modulation with NaI Scintillators) is a project aiming to set up at the new facilities of the Canfranc Underground Laboratory (LSC), a large scale NaI(Tl) experiment in order to explore the DAMA/LIBRA annual modulation positive result using the same target and technique. Two 12.5 kg each NaI(Tl) crystals provided by Alpha Spectra took data at the LSC in the ANAIS-25 set-up. The comparison of the background model for the ANAIS-25 prototypes with the experimental results is presented. ANAIS crystal radiopurity goals have been achieved for Th-232 and U-238 chains, but a Pb-210 contamination out-of-equilibrium was identified, whose origin has been studied. The high light collection efficiency obtained with these prototypes allows to anticipate an energy threshold of the order of 1 keVee. A new detector, with improved performances, was received in March 2015 and very preliminary results are shown.Comment: 6 pages, 7 figure

    Preliminary results of ANAIS-25

    Get PDF
    The ANAIS (Annual Modulation with NaI(Tl) Scintillators) experiment aims at the confirmation of the DAMA/LIBRA signal using the same target and technique at the Canfranc Underground Laboratory. 250 kg of ultrapure NaI(Tl) crystals will be used as a target, divided into 20 modules, each coupled to two photomultipliers. Two NaI(Tl) crystals of 12.5 kg each, grown by Alpha Spectra from a powder having a potassium level under the limit of our analytical techniques, form the ANAIS-25 set-up. The background contributions are being carefully studied and preliminary results are presented: their natural potassium content in the bulk has been quantified, as well as the uranium and thorium radioactive chains presence in the bulk through the discrimination of the corresponding alpha events by PSA, and due to the fast commissioning, the contribution from cosmogenic activated isotopes is clearly identified and their decay observed along the first months of data taking. Following the procedures established with ANAIS-0 and previous prototypes, bulk NaI(Tl) scintillation events selection and light collection efficiency have been also studied in ANAIS-25.Comment: 4 pages, 6 Figure

    Bulk NaI(Tl) scintillation low energy events selection with the ANAIS-0 module

    Get PDF
    Dark matter particles scattering off some target nuclei are expected to deposit very small energies in form of nuclear recoils (below 100 keV). Because of the low scintillation efficiency for nuclear recoils vs. electron recoils, in most of the scintillating targets considered in the search for dark matter, the region below 10 keVee concentrates most of the expected dark matter signal. For this reason, very low energy threshold (at or below 2 keVee) and very low background are required. This is the case of the ANAIS (Annual modulation with NaI Scintillators) experiment. A good knowledge of the detector response function for real scintillation events, a good characterization of other anomalous or noise event populations contributing in that energy range, and the development of convenient filtering procedures for the latter are mandatory to achieve the required low background at such a low energy. In this work we will present the specific protocols developed to select bulk scintillation events in NaI(Tl), and its application to data obtained with the ANAIS-0 prototype. Slight differences in time constants are expected in scintillation pulses produced by nuclear or electron recoils in NaI(Tl), so in order to analyze the effect of these filtering procedures in the case of a recoil population attributable to dark matter, data from a neutron calibration have been used.Comment: 13 pages, 22 figure

    Light yield determination in large sodium iodide detectors applied in the search for dark matter

    Get PDF
    Application of NaI(Tl) detectors in the search for galactic dark matter particles through their elastic scattering off the target nuclei is well motivated because of the long standing DAMA/LIBRA highly significant positive result on annual modulation, still requiring confirmation. For such a goal, it is mandatory to reach very low threshold in energy (at or below the keV level), very low radioactive background (at a few counts/keV/kg/day), and high detection mass (at or above the 100 kg scale). One of the most relevant technical issues is the optimization of the crystal intrinsic scintillation light yield and the efficiency of the light collecting system for large mass crystals. In the frame of the ANAIS (Annual modulation with NaI Scintillators) dark matter search project large NaI(Tl) crystals from different providers coupled to two photomultiplier tubes (PMTs) have been tested at the Canfranc Underground Laboratory. In this paper we present the estimates of the NaI(Tl) scintillation light collected using full-absorption peaks at very low energy from external and internal sources emitting gammas/electrons, and single-photoelectron events populations selected by using very low energy pulses tails. Outstanding scintillation light collection at the level of 15~photoelectrons/keV can be reported for the final design and provider chosen for ANAIS detectors. Taking into account the Quantum Efficiency of the PMT units used, the intrinsic scintillation light yield in these NaI(Tl) crystals is above 40~photoelectrons/keV for energy depositions in the range from 3 up to 25~keV. This very high light output of ANAIS crystals allows triggering below 1~keV, which is very important in order to increase the sensitivity in the direct detection of dark matter

    TP86 154. ¿Es útil el sistema de asistencia oxigenador de membrana extracorpórea en el tromboembolismo pulmonar masivo?

    Get PDF
    IntroducciónEn España, en series de autopsias se ha descubierto que la causa de muerte es un tromboembolismo pulmonar (TEP) en un 2,6%. La aparición de esta enfermedad está claramente aumentada en los pacientes oncológicos. En ocasiones las medidas clásicas del tratamiento del TEP no surgen efecto y el paciente puede fallecer; en estos casos está indicada la implantación de una asistencia cardiorrespiratoria.Material y métodosPaciente de 35 años con quimioterapia por un seminoma. Ingresa por disnea y dolor torácico con mala evolución. Se traslada a unidad de coronarias donde se diagnostica de un TEP bilateral masivo y disfunción importante ventricular derecha presentando dos episodios de parada cardiorrespiratoria. Tras las maniobras de resucitación se implanta oxigenador de membrana extracorpórea (ECMO) venoarterial que se mantiene 5 días, mientras tanto se hepariniza al paciente completamente.ResultadosEl paciente es extubado y dado de alta a los 21 días. Tras un seguimiento de 20 meses el paciente permanece vivo.ConclusiónEl sistema ECMO venoarterial es muy útil en pacientes con TEP, ya que realiza dos funciones: descargar el corazón derecho y oxigenar al paciente. Podemos heparinizar al paciente para revertir el cuadro, ya que las incisiones a nivel femoral son fácilmente controladas

    VLT spectropolarimetry of two powerful radio galaxies at z~1.4: UV continuum, emission-line properties and the nature of high-redshift dust

    Full text link
    (Abridged) Deep VLT spectropolarimetric observations are presented for two powerful radio galaxies, 0850-206 and 1303+091. These observations cover the rest-frame wavelength range ~ 1450 - 3750 A. New radio observations and continuum images of the same sources are also presented. These galaxies are the first two observed from a complete sample of nine radio sources with redshifts in the range 1.3 < z < 1.5 (selected from the equatorial sample of powerful radio sources of Best, Rottgering & Lehnert), as part of a project aimed to investigate the multi-component nature of the UV continuum in radio galaxies and any variations of the continuum properties with the radio source age. The larger radio source of the two, 0850-206, presents a high continuum fractional polarization, averaging 17% across the observed wavelength range and reaching 24% at rest-frame wavelengths of <2000 A. The smaller radio source, 1303+091, shows a lower continuum polarization, averaging 8% and rising to 11% for rest-frame wavelengths >3000 A. For both galaxies, the position angle of the electric vector is generally constant with wavelength and within ~15 degrees of perpendicular to the radio axis. Both their total flux spectra and polarized flux spectra reveal the 2200 A dust feature, and comparison with dust scattering models suggests that the composition of the dust in these galaxies is similar to that of Galactic dust. In 0850-206, scattered quasar radiation dominates the UV continuum emission, with the nebular continuum accounting for no more than ~22% and no requirement for any additional emission component such as emission from young stars. By contrast, in 1303+091, unpolarized radiation could be a major constituent of the UV continuum emission, with starlight accounting for up to ~50% and the nebular continuum accounting for ~11%.Comment: 20 pages, including 14 figures. MNRAS accepte
    corecore