14 research outputs found

    Randomized clinical trials of dental bleaching – Compliance with the CONSORT Statement: a systematic review

    Full text link

    Redes de atenção às urgências e emergências: pré-avaliação das Unidades de Pronto Atendimento (UPAs) em uma região metropolitana do Brasil Urgent and emergency care networks: a pre-evaluation of the First Aid Units (UPAs) in a metropolitan region of Brazil

    No full text
    OBJETIVOS: um estudo avaliativo, exploratório das UPAs na região metropolitana do Recife, no ano de 2011. MÉTODOS: considerou-se a descrição da intervenção, o delineamento do modelo lógico, o envolvimento dos interessados e a construção de perguntas avaliativas. Realizou-se abordagem de três fases interativas, utilizando, para sua operacionalização, a análise documental, entrevistas e Conferência de Consenso. O modelo lógico elaborado subsidiou a construção de matriz com critérios e indicadores, que foi submetida a um comitê de informantes-chave para obtenção do consenso. RESULTADOS: a matriz de critérios e indicadores resultante do consenso é composta de três níveis de análise (assistência à saúde, integração interistitucional e gestão) com 41 critérios e 74 indicadores avaliativos. Com base no modelo lógico, na Conferência de Consenso, na matriz de critérios/indicadores e nas considerações sistematizadas dos inte-ressados, foram elaboradas 14 perguntas avaliativas. CONCLUSÕES: as UPAs encontram-se adequadas à rea-lização de avaliações, pois se verificou que os elementos identificados no modelo lógico são condizentes com as condições que a intervenção possui para alcançar suas metas e objetivos.<br>OBJECTIVES: an exploratory evaluative study of the UPAs in a metropolitan region of Brazil in 2011. METHODS: the intervention was described, the logical model outlined, along with the involvement of stakeholders, and evaluation questions drawn up. The three interactive phases approach was carried out using document analysis, interviews and consensus conferencing. The logical model was based on building up a matrix of criteria and indicators that was submitted to a committee of key informants with a view to obtaining consensus. RESULTS: the matrix of criteria and indicators resulting from the consensus comprises three levels of analysis (health care, inter-institutional interaction and management) with 41 criteria and 74 evaluation indicators. Based on the logical model, the consensus conference, the matrix of criteria and indicators and the systematized considerations of interested parties, fourteen evaluation questions were drawn up. CONCLUSIONS: the UPAs are capable of carrying out evaluations, since it was found that the elements identified in the logical model are conducive to the conditions that the intervention requires in order to meet its aims and objectives

    Suspeita da perda auditiva por familiares Hearing loss suspected by the family

    No full text
    OBJETIVOS: caracterizar e analisar a suspeita de perda auditiva, por parte de familiares, em crianças assistidas na Associação de Pais e Amigos do Deficiente Auditivo (APADA) em Teresina-PI. MÉTODOS: estudo descritivo realizado na APADA no período de setembro a outubro de 2006, com aplicação de formulários para 14 mães e/ou responsáveis para levantamento das variáveis: identificar o familiar que suspeitou da perda auditiva na criança; o motivo que levou a suspeita; a idade da criança quando da detecção pelo familiar; a atitude da família após a descoberta da perda auditiva; a idade da criança quando ocorreu procura profissional e a orientação recebida; o tempo entre a suspeita da perda auditiva, por parte do familiar, e a confirmação profissional de diagnóstico. RESULTADOS: os dados apontam que 86% da suspeita foi percebido pelas mães. O motivo da suspeita foi pela não reação ao som por parte da criança (71%). 36% dos familiares perceberam o problema na idade de 7 a 12 meses. 79% tiveram como primeira atitude procurar o médico, 36% procuraram o profissional da saúde com até um ano de idade, 29% receberam a orientação do profissional para o uso do aparelho auditivo e tiveram a confirmação da perda auditiva de 7 meses a 1 ano de idade ou após os 4 anos. CONCLUSÃO: o diagnóstico da perda auditiva foi tardio frente a suspeita por parte dos familiares e dos profissionais de saúde e não estiveram relacionadas com os programas da triagem auditiva neonatal.<br>PURPOSE: to analyze and characterize children suspected by the family of hearing loss attended at Associação de Pais e Amigos do Deficiente Auditivo (APADA) in Teresina, PI. METHODS: a descriptive study was carried out at PFHIA from September to October 2006. Form were filled out by 14 mothers and/or the responsible adult to find the following variables: identify the family member who suspected hearing loss in the child; the reason which led to the suspicion; the age of the child when hearing loss was detected by the family member; the attitude of the family after discovering the hearing loss; the age of the child when professional help was obtained and the orientation received; the time lapse from suspicion of hearing loss by the family to professional confirmation. RESULTS: the data shows that hearing loss was suspected by the mothers in 86%. The reason for the suspicion was no reaction to sound from the child (71%). 36% of the families noticed the problem at the age of 7 to 12 months, 79% looked for medical help as their first attitude, 36% looked for a health professional before 1 year of age, 29% received the health orientation to use hearing aids and had the confirmation of hearing loss from 7 months to 1 year of age or after the age of 4. CONCLUSION: the diagnosis of hearing loss was late and discovered by members of the family and health professionals and was not related to newborn hearing screening programs

    Potencial evocado auditivo de tronco encefálico por via óssea em indivíduos com perda auditiva sensorioneural Brainstem auditory evoked potential in subjects with sensorineural hearing losses

    Get PDF
    OBJETIVO: caracterizar os resultados do PEATE por via óssea em indivíduos com perda auditiva sensorioneural leve, comparando esses dados com o grupo controle, formado por indivíduos audiologicamente normais. MÉTODO: a amostra foi constituída por 40 adultos, de ambos os sexos, com faixa etária de 18 a 55 anos, distribuídos em um grupo controle de 30 indivíduos com audição normal e um grupo estudo composto de 10 indivíduos com perda auditiva sensorioneural de grau leve. O PEATE foi realizado com equipamento EP15, da marca Interacoustics. O estímulo utilizado foi o clique com taxa de apresentação de 27,7/s, em um total de 2000 estímulos, com polaridade de rarefação por VA e alternada para VO e filtro passa-banda de 50Hz e 3000Hz. RESULTADOS: em indivíduos com perda sensorioneural de grau leve, não houve diferenças estatisticamente significantes entre o limiar do PEATE por via aérea e óssea, estando esses limiares equivalentes, com GAP aéreo-ósseo menor que 10dB. A latência da onda V no limiar eletrofisiológico e a 50 dBnNA foram menores que as referidas latências observadas em indivíduos com audição normal. CONCLUSÃO: foram encontrados limiares eletrofisiológicos por via óssea equivalente aos limiares obtidos por via aérea, com presença de GAP aéreo-ósseo menor que 10dBnNA. Assim a utilização do PEATE por VO fornece dados para uma caracterização mais detalhada do tipo da perda auditiva.<br>PURPOSE: to characterize the results of ABR via bone in subjects with mild sensorineural hearing loss, comparing these data with the control group made up by subjects with normal hearing. METHOD: the sample consisted of 40 adults of both genders, 18 - 55 year old, divided into a control group of 30 subjects with normal hearing and a study group made up of 10 subjects with mild sensorineural hearing loss. ABR was carried out with Interacoustics brand EP15. The stimulus was the click presentation rate of 27.7 / s, for a total of 2000 stimuli with rarefaction polarity for AC and switched to VO and band-pass filter of 50Hz and 3000Hz. RESULTS: in subjects with mild sensorineural loss, there were no statistically significant differences between the ABR threshold via air and bone, and those thresholds were equivalent, with air-bone gap of less than 10dB. The latencies of wave V in the electrophysiological threshold and 50 dBnNA were lower latencies than those noted in subjects with normal hearing. CONCLUSION: we found electrophysiological thresholds via bone equivalent to thresholds obtained via air, with the presence of air-bone gap being less than 10dBnNA. Thus, the use of VO by ABR provides data for a more-detailed characterization of the type of hearing loss

    Influência do processo de secagem sobre os principais componentes químicos do óleo essencial de tomilho

    Get PDF
    Objetivou-se, com este trabalho, avaliar o efeito da temperatura do ar de secagem sobre a qualidade do óleo essencial de folhas de tomilho. Foram empregadas diferentes temperaturas de secagem (30, 40, 50, 60, 70 ºC), em um secador com resistências elétricas. Os componentes químicos do óleo essencial, depois de realizada a secagem, foram comparados com os valores obtidos na planta in natura (testemunha). Para a extração do óleo essencial, foi empregado o método de extração com CO2 supercrítico. A identificação dos componentes químicos do óleo essencial foi realizada por cromatografia gasosa, acoplada ao espectrofotômetro de massas (CG-EM) e, para a quantificação desses componentes, empregou-se o cromatógrafo a gás, acoplado ao detector por ionização de chamas (CG-DIC). Em função dos resultados obtidos, recomenda-se ar, à temperatura de 60 ºC, para a secagem das folhas de tomilho
    corecore