132 research outputs found

    Neonatal critical illness and development: white matter and hippocampus alterations in school-age neonatal ECMO survivors

    Get PDF
    Aim: Examine the neurobiology of long-term neuropsychological deficits following neonatal extracorporeal membrane oxygenation (ECMO). Method: This cross-sectional study assessed white matter integrity and hippocampal volume of ECMO survivors (8-15yrs) and healthy controls (8-17yrs) using Diffusion Tensor Imaging and structural MRI, respectively. Neuropsychological outcome was evaluated in patients. Included clinical predictors of white matter integrity: age start ECMO, ECMO duration, highest oxygenation index before ECMO, highest mean airway pressure and mechanical ventilation duration. Results: Patients (n=23) had lower global fractional anisotropy than controls (n=54)(patients=.368; controls=.381; p=.02), but similar global mean diffusivity (p=.41). Patients had lower fractional anisotropy in the left cingulum bundle (patients=.345; controls=.399; p<.001) and higher mean diffusivity in a region of the left parahippocampal cingulum (patients=.916; controls=.871; p<.001). Higher global mean diffusivity predicted worse verbal memory in patients (n=17)(β=-.74, p=.01). Patients (n=23) had smaller bilateral hippocampal volume than controls (n=43)(left: p< .001; right: p< .001). In patients, this was related to worse verbal memory (left: β=.65, p=.02; right: β=.71, p=.01). Interpretation: Neonatal ECMO survivors are at risk for long-term brain alterations, which may partly explain long-term neuropsychological impairments. Neuroimaging may contribute to better risk stratification of long-term impairments

    Contemporary use of devices in chronic heart failure in the Netherlands

    Get PDF
    Aims: Despite previous surveys regarding device implantation rates in heart failure (HF), insight into the real-world management with devices is scarce. Therefore, we investigated device implantation rates in HF with reduced left ventricular ejection fraction (LVEF) in 34 Dutch centres. Methods and results: A cross-sectional outpatient registry was conducted in 6666 patients with LVEF < 50% and with information about device implantation available [74 (66–81) years of age; 64% male]. Patients were classified into conventional pacemakers (PM, n = 562), implantable cardioverter defibrillato

    Evaluation of a seven gene mutational profile as a prognostic factor in a population-based study of clear cell renal cell carcinoma

    Get PDF
    In this study, we investigate the influence of the seven genes (VHL, PBRM1, SETD2, BAP1, KDM5C, MTOR and TP53) most frequently mutated in clear cell renal cell cancer (ccRCC) on cancer-specific survival (CSS) in the prospective Netherlands Cohort Study on diet and cancer. DNA isolated from routinely archived formalin-fixed paraffin-embedded tumour blocks from 252 incident ccRCC cases was available for targeted next generation sequencing. Based on the sequencing quality and the completeness of information on clinical characteristics and follow-up, we could use 110 cases for survival analysis. The association with CSS for each mutated gene in these cases was tested using multivariable Cox proportional hazards models to estimate hazards ratios (HR) and confidence intervals (CIs), and we observed mutations in one or more of the seven genes in 64 out of 110 cases (58%). In the multivariable-adjusted analyses, mutations in VHL and PBRM1 were associated with better CSS (HRs (95% CI) 0.34 (0.13‒0.89) and 0.17 (0.04–0.66), respectively), although these results were not statistically significant after multiple testing correction. No association was observed for the other five genes, which may be attributable to limited power

    Persistent inhibition of neointimal hyperplasia after sirolimus-eluting stent implantation: long-term (up to 2 years) clinical, angiographic, and intravascular ultrasound follow-up

    Get PDF
    BACKGROUND: Early results of sirolimus-eluting stent implantation showed a nearly complete abolition of neointimal hyperplasia. The question remains, however, whether the early promising results will still be evident at long-term follow-up. The objective of our study was to evaluate the efficiency of sirolimus-eluting stent implantation for up to 2 years of follow-up. METHODS AND RESULTS: Fifteen patients with de novo coronary artery disease were treated with 18-mm sirolimus-eluting Bx-Velocity stents (Cordis) loaded with 140 microg sirolimus/cm2 metal surface area in a slow release formulation. Quantitative angiography (QCA) and intravascular ultrasound (IVUS) were performed according to standard protocol. Sirolimus-eluting stent implantation was successful in all 15 patients. During the in-hospital course, 1 patient died of cerebral hemorrhage after periprocedural administration of abciximab, and 1 patient underwent repeat stenting after 2 hours because of edge dissection that led to acute occlusion. Through 6 months and up to 2 years of follow-up, no additional events occurred. QCA analysis revea

    Direct Stenting versus Conventional Stenting in Patients with ST-Segment Elevation Myocardial Infarction—A COMPARE CRUSH Sub-Study

    Get PDF
    Background: Direct stenting (DS) compared with conventional stenting (CS) after balloon predilatation may reduce distal embolization during percutaneous coronary intervention (PCI), thereby improving tissue reperfusion. In contrast, DS may increase the risk of stent underexpansion and target lesion failure. Methods:In this sub-study of the randomized COMPARE CRUSH trial (NCT03296540), we reviewed the efficacy of DS versus CS in a cohort of contemporary, pretreated ST-segment elevation myocardial infarction (STEMI) patients undergoing primary PCI. We compared DS versus CS, assessing (1) stent diameter in the culprit lesion, (2) thrombolysis in myocardial infarction (TIMI) flow in the infarct-related artery post-PCI and complete ST-segment resolution (STR) one-hour post-PCI, and (3) target lesion failure at one year. For proportional variables, propensity score weighting was applied to account for potential treatment selection bias. Results: This prespecified sub-study included 446 patients, of whom 189 (42%) were treated with DS. Stent diameters were comparable between groups (3.2 ± 0.5 vs. 3.2 ± 0.5 mm, p = 0.17). Post-PCI TIMI 3 flow and complete STR post-PCI rates were similar between groups (DS 93% vs. CS 90%, adjusted OR 1.16 [95% CI, 0.56–2.39], p = 0.69, and DS 72% vs. CS 58%, adjusted OR 1.29 [95% CI 0.77–2.16], p = 0.34, respectively). Moreover, target lesion failure rates at one year were comparable (DS 2% vs. 1%, adjusted OR 2.93 [95% CI 0.52–16.49], p = 0.22). Conclusion:In this contemporary pretreated STEMI cohort, we found no difference in early myocardial reperfusion outcomes between DS and CS. Moreover, DS seemed comparable to CS in terms of stent diameter and one-year vessel patency.</p

    Cochlear implant programming: a global survey on the state of the art

    Get PDF
    The programming of CIs is essential for good performance. However, no Good Clinical Practice guidelines exist. This paper reports on the results of an inventory of the current practice worldwide. A questionnaire was distributed to 47 CI centers. They follow 47600 recipients in 17 countries and 5 continents. The results were discussed during a debate. Sixty-two percent of the results were verified through individual interviews during the following months. Most centers (72%) participated in a cross-sectional study logging 5 consecutive fitting sessions in 5 different recipients. Data indicate that general practice starts with a single switch-on session, followed by three monthly sessions, three quarterly sessions, and then annual sessions, all containing one hour of programming and testing. The main focus lies on setting maximum and, to a lesser extent, minimum current levels per electrode. These levels are often determined on a few electrodes and then extrapolated. They are mainly based on subjective loudness perception by the CI user and, to a lesser extent, on pure tone and speech audiometry. Objective measures play a small role as indication of the global MAP profile. Other MAP parameters are rarely modified. Measurable targets are only defined for pure tone audiometry. Huge variation exists between centers on all aspects of the fitting practice

    Whole genome sequencing for USH2A-associated disease reveals several pathogenic deep-intronic variants that are amenable to splice correction

    Full text link
    A significant number of individuals with a rare disorder such as Usher syndrome (USH) and (non-)syndromic autosomal recessive retinitis pigmentosa (arRP) remain genetically unexplained. Therefore, we assessed subjects suspected of USH2A-associated disease and no or mono-allelic USH2A variants using whole genome sequencing (WGS) followed by an improved pipeline for variant interpretation to provide a conclusive diagnosis. One hundred subjects were screened using WGS to identify causative variants in USH2A or other USH/arRP-associated genes. In addition to the existing variant interpretation pipeline, a particular focus was put on assessing splice-affecting properties of variants, both in silico and in vitro. Also structural variants were extensively addressed. For variants resulting in pseudoexon inclusion, we designed and evaluated antisense oligonucleotides (AONs) using minigene splice assays and patient-derived photoreceptor precursor cells. Biallelic variants were identified in 49 of 100 subjects, including novel splice-affecting variants and structural variants, in USH2A or arRP/USH-associated genes. Thirteen variants were shown to affect USH2A pre-mRNA splicing, including four deep-intronic USH2A variants resulting in pseudoexon inclusion, which could be corrected upon AON treatment. We have shown that WGS, combined with a thorough variant interpretation pipeline focused on assessing pre-mRNA splicing defects and structural variants, is a powerful method to provide subjects with a rare genetic condition, a (likely) conclusive genetic diagnosis. This is essential for the development of future personalized treatments and for patients to be eligible for such treatments

    Development and measurement of guidelines-based quality indicators of caesarean section care in the Netherlands: A RAND-modified delphi procedure and retrospective medical chart review

    Get PDF
    Background There is an ongoing discussion on the rising CS rate worldwide. Suboptimal guideline adherence may be an important contributor to this rise. Before improvement of care can be established, optimal CS care in different settings has to be defined. This study aimed to develop and measure quality indicators to determine guideline adherence and identify target groups for improvement of care with direct effect on caesarean section (CS) rates. Method Eighteen obstetricians and midwives participated in an expert panel for systematic CS quality indicator development according to the RAND-modified Delphi method. A multi-center study was performed and medical charts of 1024 women with a CS and a stratified and weighted randomly selected group of 1036 women with a vaginal delivery were analysed. Quality indicator frequency and adherence were scored in 2060 women with a CS or vaginal delivery. Results The expert panel developed 16 indicators on planned CS and 11 indicators on unplanned CS. Indicator adherence was calculated, defined as the number of women in a specific obstetrical situation in which care was performed as recommended in both planned and unplanned CS settings. The most frequently occurring obstetrical situations with low indicator adherence were: 1) suspected fetal distress (frequency 17%, adh
    • …
    corecore