194 research outputs found

    The implementation of an external quality assurance method for point- of- care tests for HIV and syphilis in Tanzania.

    Get PDF
    BACKGROUND: External quality assurance (EQA) programmes, which are routinely used in laboratories, have not been widely implemented for point-of- care tests (POCTs). A study was performed in ten health centres in Tanzania, to implement the use of dried blood spots (DBS) as an EQA method for HIV and syphilis (POCTs). METHOD: DBS samples were collected for retesting at a reference laboratory and the results compared to the POCT results obtained at the clinic. In total, 2341 DBS samples were collected from 10 rural health facilities over a period of nine months, of which 92.5% were correctly collected and spotted. RESULTS: The EQA method was easily implemented by healthcare workers under routine conditions in Northern Tanzania. For HIV, 967 out of 972 samples (99.5%) were concordant between DBS and POCT results. For syphilis, the sensitivity of syphilis tests varied between clinics with a median of 96% (25th and 75th quartile; 95-98%). The specificity of syphilis POCT was consistent compared to laboratory based test using DBS, with a median of 96% (25th and 75th quartiles; 95-98%). CONCLUSION: Overall, the quality of testing varied at clinics and EQA results can be used to identify clinics where healthcare workers require remedial training, suggesting the necessity for stringent quality assurance programmes for POC testing. As Tanzania embarks on scaling up HIV and syphilis testing, DBS can be a useful and robust tool to monitor the quality of testing performed by healthcare workers and trigger corrective action to ensure accuracy of test results

    The trade-off between accuracy and accessibility of syphilis screening assays.

    Get PDF
    The availability of rapid and sensitive methods to diagnose syphilis facilitates screening of pregnant women, which is one of the most cost-effective health interventions available. We have evaluated two screening methods in Tanzania: an enzyme immunoassay (EIA), and a point-of-care test (POCT). We evaluated the performance of each test against the Treponema pallidum particle agglutination assay (TPPA) as the reference method, and the accessibility of testing in a rural district of Tanzania. The POCT was performed in the clinic on whole blood, while the other assays were performed on plasma in the laboratory. Samples were also tested by the rapid plasma Reagin (RPR) test. With TPPA as reference assay, the sensitivity and specificity of EIA were 95.3% and 97.8%, and of the POCT were 59.6% and 99.4% respectively. The sensitivity of the POCT and EIA for active syphilis cases (TPPA positive and RPR titer ≥ 1/8) were 82% and 100% respectively. Only 15% of antenatal clinic attenders in this district visited a health facility with a laboratory capable of performing the EIA. Although it is less sensitive than EIA, its greater accessibility, and the fact that treatment can be given on the same day, means that the use of POCT would result in a higher proportion of women with syphilis receiving treatment than with the EIA in this district of Tanzania

    Dried blood spots for qPCR diagnosis of acute Bartonella bacilliformis infection.

    Get PDF
    Bartonella bacilliformis is the etiological agent of a life-threatening illness. Thin blood smear is the most common diagnostic method for acute infection in endemic areas of Peru but remains of limited value because of low sensitivity. The aim of this study was to adapt a B. bacilliformis-specific real-time polymerase chain reaction (PCR) assay for use with dried blood spots (DBS) as a sampling method and assess its performance and use for the diagnosis and surveillance of acute Bartonella infection. Only two of 65 children (3%) that participated in this study had positive blood smears for B. bacilliformis, whereas 16 (including these two) were positive by PCR performed on DBS samples (24.6%). The use of DBS in combination with B. bacilliformis-specific PCR could be a useful tool for public health in identifying and monitoring outbreaks of infection and designing control programs to reduce the burden of this life-threatening illness

    Pharmacological aspects of neonatal antidepressant withdrawal

    Get PDF
    Depression is common in reproductive age women, and continued pharmacologic treatment of depression during pregnancy may be necessary to prevent relapse, which could be harmful for both the fetus and the mother. Although data on drug safety are imperfect and incomplete, the benefits of antidepressant therapy during pregnancy generally outweigh the risks. Neonates who are exposed to antidepressant medications during gestation are at increased risk to have neonatal withdrawal syndrome, although the exact incidence of this complication is unknown because the definition of the syndrome is not clear and withdrawal reactions are probably underreported. Tricyclic antidepressant withdrawal syndrome is most likely related to muscarinergic activity and individual drug half-lives, and selective serotonin reuptake inhibitor withdrawal may be due to a decrease in available synaptic serotonin in the face of down-regulated serotonin receptors, the secondary effects of other neurotransmitters, and biological or cognitive sensitivity. Other factors that influence neonatal toxicity or withdrawal include the normal physiologic changes of pregnancy, the altered activity of CYP450 enzymes during pregnancy, drug-drug transporter (PgP and OCT3) interaction, and the presence of genetic polymorphisms in genes influencing drug metabolism. Further research is necessary

    Systematic review of the performance of HIV viral load technologies on plasma samples.

    Get PDF
    BACKGROUND: Viral load (VL) monitoring is the standard of care in developing country settings for detecting HIV treatment failure. Since 2010 the World Health Organization has recommended a phase-in approach to VL monitoring in resource-limited settings. We conducted a systematic review of the accuracy and precision of HIV VL technologies for treatment monitoring. METHODS AND FINDINGS: A search of Medline and Embase was conducted for studies evaluating the accuracy or reproducibility of commercially available HIV VL assays. 37 studies were included for review including evaluations of the Amplicor Monitor HIV-1 v1.5 (n = 25), Cobas TaqMan v2.0 (n = 11), Abbott RealTime HIV-1 (n = 23), Versant HIV-1 RNA bDNA 3.0 (n = 15), Versant HIV-1 RNA kPCR 1.0 (n = 2), ExaVir Load v3 (n = 2), and NucliSens EasyQ v2.0 (n = 1). All currently available HIV VL assays are of sufficient sensitivity to detect plasma virus levels at a lower detection limit of 1,000 copies/mL. Bias data comparing the Abbott RealTime HIV-1, TaqMan v2.0 to the Amplicor Monitor v1.5 showed a tendency of the Abbott RealTime HIV-1 to under-estimate results while the TaqMan v2.0 overestimated VL counts. Compared to the Amplicor Monitor v1.5, 2-26% and 9-70% of results from the Versant bDNA 3.0 and Abbott RealTime HIV-1 differed by greater than 0.5log10. The average intra and inter-assay variation of the Abbott RealTime HIV-1 were 2.95% (range 2.0-5.1%) and 5.44% (range 1.17-30.00%) across the range of VL counts (2log10-7log10). CONCLUSIONS: This review found that all currently available HIV VL assays are of sufficient sensitivity to detect plasma VL of 1,000 copies/mL as a threshold to initiate investigations of treatment adherence or possible treatment failure. Sources of variability between VL assays include differences in technology platform, plasma input volume, and ability to detect HIV-1 subtypes. Monitoring of individual patients should be performed on the same technology platform to ensure appropriate interpretation of changes in VL. Prospero registration # CD42013003603

    Systematic review of the use of dried blood spots for monitoring HIV viral load and for early infant diagnosis.

    Get PDF
    BACKGROUND: Dried blood spots (DBS) have been used as alternative specimens to plasma to increase access to HIV viral load (VL) monitoring and early infant diagnosis (EID) in remote settings. We systematically reviewed evidence on the performance of DBS compared to plasma for VL monitoring and EID. METHODS AND FINDINGS: Thirteen peer reviewed HIV VL publications and five HIV EID papers were included. Depending on the technology and the viral load distribution in the study population, the percentage of DBS samples that are within 0.5 log of VL in plasma ranged from 52-100%. Because the input sample volume is much smaller in a blood spot, there is a risk of false negatives with DBS. Sensitivity of DBS VL was found to be 78-100% compared to plasma at VL below 1000 copies/ml, but this increased to 100% at a threshold of 5000 copies/ml. Unlike a plasma VL test which measures only cell free HIV RNA, a DBS VL also measures proviral DNA as well as cell-associated RNA, potentially leading to false positive results when using DBS. The systematic review showed that specificity was close to 100% at DBS VL above 5000 copies/ml, and this threshold would be the most reliable for predicting true virologic failure using DBS. For early infant diagnosis, DBS has a sensitivity of 100% compared to fresh whole blood or plasma in all studies. CONCLUSIONS: Although limited data are available for EID, DBS offer a highly sensitive and specific sampling strategy to make viral load monitoring and early infant diagnosis more accessible in remote settings. A standardized approach for sampling, storing, and processing DBS samples would be essential to allow successful implementation. TRIAL REGISTRATION: PROSPERO Registration #: CRD42013003621

    Long-term surgical outcomes of congenital supravalvular aortic stenosis:a systematic review, meta-analysis and microsimulation study

    Get PDF
    OBJECTIVES: Congenital supravalvular aortic stenosis (SVAS) is a rare form of congenital outflow tract obstruction and long-term outcomes are scarcely reported. This study aims to provide an overview of outcomes after surgical repair for congenital SVAS. METHODS: A systematic review of published literature was conducted, including observational studies reporting long-term clinical outcome (&gt;2 years) after SVAS repair in children or adults considering &gt;20 patients. Early risks, late event rates and time-to-event data were pooled and entered into a microsimulation model to estimate 30-year outcomes. Life expectancy was compared to the age-, sex- and origin-matched general population. RESULTS: Twenty-three publications were included, encompassing a total of 1472 patients (13 125 patient-years; pooled mean follow-up: 9.0 (6.2) years; median follow-up: 6.3 years). Pooled mean age at surgical repair was 4.7 (5.8) years and the most commonly used surgical technique was the single-patch repair (43.6%). Pooled early mortality was 4.2% (95% confidence interval: 3.2-5.5%) and late mortality was 0.61% (95% CI: 0.45-0.83) per patient-year. Based on microsimulation, over a 30-year time horizon, it was estimated that an average patient with SVAS repair (mean age: 4.7 years) had an observed life expectancy that was 90.7% (95% credible interval: 90.0-91.6%) of expected life expectancy in the matched general population. The microsimulation-based 30-year risk of myocardial infarction was 8.1% (95% credible interval: 7.3-9.9%) and reintervention 31.3% (95% credible interval: 29.6-33.4%), of which 27.2% (95% credible interval: 25.8-29.1) due to repair dysfunction. CONCLUSIONS: After surgical repair for SVAS, 30-year survival is lower than the matched-general-population survival and the lifetime risk of reintervention is considerable. Therefore, lifelong monitoring of the cardiovascular system and in particular residual stenosis and coronary obstruction is recommended.</p
    • …
    corecore