717 research outputs found

    High-bandwidth uni-traveling carrier waveguide photodetector on an InP-membrane-on-silicon platform

    Get PDF
    A uni-traveling carrier photodetector (UTC-PD), heterogeneously integrated on silicon, is demonstrated. It is fabricated in an InP-based photonic membrane bonded on a silicon wafer, using a novel double-sided processing scheme. A very high 3 dB bandwidth of beyond 67 GHz is obtained, together with a responsivity of 0.7 A/W at 1.55 ÎŒm wavelength. In addition, open eye diagrams at 54 Gb/s are observed. These results promise high speed applications using a novel full-functionality photonic platform on silicon

    Oxidation of AlInAs for current blocking in a photonic crystal laser

    Get PDF
    To make an electrically pumped photonic crystal membrane laser is a challenging task. One of the problems is how to avoid short circuiting between the p- and n-doped parts of the laser diode, when the membrane thickness is limited to 200-300nm. We propose to use the oxide of AlInAs to realize a current blocking function. In this way, based on submicron selective area re-growth, we aim for electrically injected photonic crystal lasers with high output power, small threshold currents and low power consumption. Here results are presented on the oxidation of AlInAs. The results show that it is feasible to use the oxide of AlInAs for current blocking in an InP-based membrane photonic crystal laser

    Silicon-on-insulator shortwave infrared wavelength meter with integrated photodiodes for on-chip laser monitoring

    Get PDF
    This paper demonstrates a very compact wavelength meter for on-chip laser monitoring in the shortwave infrared wavelength range based on an optimized arrayed waveguide grating (AWG) filter with an integrated photodiode array. The AWG response is designed to obtain large nearest neighbor crosstalk (i. e. large overlap) between output channels, which allows accurately measuring the wavelength of a laser under test using the centroid detection technique. The passive AWG is fabricated on a 220 nm silicon-on-insulator (SOI) platform and is combined with GaInAsSb-based photodiodes. The photodiodes are heterogeneously integrated on the output grating couplers of the AWG using DVS-BCB adhesive bonding. The complete device with AWG and detectors has a footprint of only 2 mm(2) while the measured accuracy and resolution of the detected wavelength is better than 20pm. (C)2014 Optical Society of Americ

    Design of a new ultra-small polarization converter in InGaAsP/InP membrane

    Get PDF
    The design of an ultra-small (4.1 ”m length) polarization converter in Indium phosphide (InP) membrane is presented. The device is modelled using a vectorial 2D mode solver. Simulations show strong conversion (> 94%) and low-loss operation (<0.5 dB) over a wavelength range of 200 nm. A description of a possible fabrication scheme for the device using standard InP technology is also given

    Low-optical-loss, low-resistance Ag/Ge based ohmic contacts to n-type InP for membrane based waveguide devices

    Get PDF
    We present the development of Ag/Ge based ohmic contacts to n-type InP with both low contact resistances and relatively low optical losses. A specific contact resistance as low as 1.5×10-6 O cm2 is achieved by optimizing the Ge layer thickness and annealing conditions. The use of Ge instead of metal as the first deposited layer results in a low optical absorption loss in the telecommunication wavelength range. Compared to Au based contacts, the Ag based metallization also shows considerably reduced spiking effects after annealing. Contacts with different lengths are deposited on top of InP membrane waveguides to characterize the optical loss before and after annealing. A factor of 5 reduction of the propagation loss compared to the conventional Au/Ge/Ni contact is demonstrated. This allows for much more optimized designs for membrane photonic devices

    The effects of an Internet based self-help course for reducing panic symptoms - Don't Panic Online: study protocol for a randomised controlled trial

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Internet based self-help for panic disorder (PD) has proven to be effective. However, studies so far have focussed on treating a full-blown disorder. Panic symptoms that do not meet DSM-IV criteria are more prevalent than the full-blown disorder and patients with sub-clinical panic symptoms are at risk of developing PD. This study is a randomised controlled trial aimed to evaluate an Internet based self-help intervention for sub-clinical and mild PD compared to a waiting list control group.</p> <p>Methods</p> <p>Participants with mild or sub-clinical PD (N = 128) will be recruited in the general population. Severity of panic and anxiety symptoms are the primary outcome measures. Secondary outcomes include depressive symptoms, quality of life, loss of production and health care consumption. Assessments will take place on the Internet at baseline and three months after baseline.</p> <p>Discussion</p> <p>Results will indicate the effectiveness of Internet based self-help for sub-clinical and mild PD. Strengths of this design are the external validity and the fact that it is almost completely conducted online.</p> <p>Trial registration</p> <p>Netherlands Trial Register (NTR): <a href="http://www.trialregister.nl/trialreg/admin/rctview.asp?TC=1639">NTR1639</a> The Netherlands Trial Register is part of the Dutch Cochrane Centre.</p

    Heterologous infection and vaccination shapes immunity against SARS-CoV-2 variants

    Get PDF
    [Figure: see text].The impact of initial severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infecting strain on downstream immunity to heterologous variants of concern (VOC) is unknown. Studying a longitudinal healthcare worker cohort, we found that after three antigen exposures (infection+two vaccine doses), S1 antibody, memory B cells and heterologous neutralization of B.1.351, P.1 and B.1.617.2 plateaued, while B.1.1.7 neutralization and spike T cell responses increased. Serology using Wuhan Hu-1 spike receptor binding domain poorly predicted neutralizing immunity against VOCs. Neutralization potency against VOCs changed with heterologous virus encounter and number of antigen exposures. Neutralization potency fell differentially depending on targeted VOCs over 5-months from the second vaccine dose. Heterologous combinations of spike encountered during infection and vaccination shape subsequent cross-protection against VOC, with implications for future-proof next-generation vaccines

    Advances in small lasers

    Get PDF
    M.T.H was supported by an Australian Research council Future Fellowship research grant for this work. M.C.G. is grateful to the Scottish Funding Council (via SUPA) for financial support.Small lasers have dimensions or modes sizes close to or smaller than the wavelength of emitted light. In recent years there has been significant progress towards reducing the size and improving the characteristics of these devices. This work has been led primarily by the innovative use of new materials and cavity designs. This Review summarizes some of the latest developments, particularly in metallic and plasmonic lasers, improvements in small dielectric lasers, and the emerging area of small bio-compatible or bio-derived lasers. We examine the different approaches employed to reduce size and how they result in significant differences in the final device, particularly between metal- and dielectric-cavity lasers. We also present potential applications for the various forms of small lasers, and indicate where further developments are required.PostprintPeer reviewe

    Single-inhaler triple therapy fluticasone furoate/umeclidinium/vilanterol versus dual therapy in current and former smokers with COPD: IMPACT trial post hoc analysis.

    Get PDF
    This is the final version. Available from Elsevier via the DOI in this record. Data sharing: Anonymized individual participant data and study documents can be requested for further research from www.clinicalstudydatarequest.com.BACKGROUND: Smoking is the major risk factor for chronic obstructive pulmonary disease (COPD). In IMPACT, single-inhaler fluticasone furoate/umeclidinium/vilanterol (FF/UMEC/VI) triple therapy significantly reduced moderate/severe exacerbation rates and improved lung function and health status versus FF/VI or UMEC/VI in COPD patients. This post hoc analysis investigated trial outcomes by smoking status. METHODS: IMPACT was a double-blind, 52-week trial. Patients aged ≄40 years with symptomatic COPD and ≄1 moderate/severe exacerbation in the prior year were randomized 2:2:1 to FF/UMEC/VI 100/62.5/25 Όg, FF/VI 100/25 Όg, or UMEC/VI 62.5/25 Όg. Endpoints assessed by smoking status at screening included rate and risk of moderate/severe exacerbations, change from baseline in trough forced expiratory volume in 1 s, and St George's Respiratory Questionnaire total score at Week 52. Safety was also assessed. RESULTS: Of the 10,355 patients in the intent-to-treat population, 3,587 (35%) were current smokers. FF/UMEC/VI significantly reduced on-treatment moderate/severe exacerbation rates versus FF/VI and UMEC/VI in current (rate ratio 0.85 [95% confidence interval: 0.77-0.95]; P = 0.003 and 0.86 [0.76-0.98]; P = 0.021) and former smokers (0.85 [0.78-0.91]; P < 0.001 and 0.70 [0.64-0.77]; P < 0.001). FF/UMEC/VI significantly reduced time-to-first on-treatment moderate/severe exacerbation versus FF/VI and UMEC/VI in former smokers, and versus FF/VI in current smokers. Similar trends were seen for lung function and health status. Former smokers receiving inhaled corticosteroid-containing therapy had higher pneumonia incidence than current smokers. CONCLUSIONS: FF/UMEC/VI improved clinical outcomes versus dual therapy regardless of smoking status. Benefits of FF/UMEC/VI versus UMEC/VI were greatest in former smokers, potentially due to relative corticosteroid resistance in current smokers. CLINICAL TRIAL REGISTRATION: GSK (CTT116855/NCT02164513).GlaxoSmithKleinGlaxoSmithKlei
    • 

    corecore