1,568 research outputs found

    Radiation from carbon in a rocket plume mixing region with coupled convective and radiative energy fluxes and general optical thickness

    Get PDF
    Carbon radiant heat transfer from plume mixing region to base of rocket vehicl

    Computation of unsteady transonic flows through rotating and stationary cascades. 3: Acoustic far-field analysis

    Get PDF
    A small perturbation type analysis has been developed for the acoustic far field in an infinite duct extending upstream and downstream of an axial turbomachinery stage. The analysis is designed to interface with a numerical solution of the near field of the blade rows and, thereby, to provide the necessary closure condition to complete the statement of infinite duct boundary conditions for the subject problem. The present analysis differs from conventional inlet duct analyses in that a simple harmonic time dependence was not assumed, since a transient signal is generated by the numerical near-field solution and periodicity is attained only asymptotically. A description of the computer code developed to carry out the necessary convolutions numerically is included, as well as the results of a sample application using an impulsively initiated harmonic signal

    Investigation of combustion of hydrogen in a hypersonic air-stream Final report

    Get PDF
    Hydrogen fuel combustion hazard and venting problems from launch vehicles in hypersonic air flo

    Time-dependent transonic flow solutions for axial turbomachinery

    Get PDF
    Three-dimensional unsteady transonic flow through an axial turbomachine stage is described in terms of a pair of two-dimensional formulations pertaining to orthogonal surfaces, namely, a blade-to-blade surface and a hub-to-casing surface. The resulting systems of nonlinear, inviscid, compressible equations of motion are solved by an explicit finite-difference technique. The blade-to-blade program includes the periodic interaction between rotor and stator blade rows. Treatment of the boundary conditions and of the blade slipstream motion by a characteristic type procedure is discussed in detail. Harmonic analysis of the acoustic far field produced by the blade row interaction, including an arbitrary initial transient, is outlined. Results from the blade-to-blade program are compared with experimental measurements of the rotating pressure field at the tip of a high-speed fan. The hub-to-casing program determines circumferentially averaged flow properties on a meridional plane. Blade row interactions are neglected in this formulation, but the force distributions over the entire blade surface for both the rotor and stator are obtained. Results from the hub-to-casing program are compared with a relaxation method solution for a subsonic rotor. Results are also presented for a quiet fan stage which includes transonic flow in both the rotor and stator and a normal shock in the stator

    Search for Majorana neutrinos with the first two years of EXO-200 data

    Get PDF
    Many extensions of the standard model of particle physics suggest that neutrinos should be Majorana-type fermions—that is, that neutrinos are their own anti-particles—but this assumption is difficult to confirm. Observation of neutrinoless double-β decay (0νββ), a spontaneous transition that may occur in several candidate nuclei, would verify the Majorana nature of the neutrino and constrain the absolute scale of the neutrino mass spectrum. Recent searches carried out with ^(76)Ge (the GERDA experiment) and ^(136)Xe (the KamLAND-Zen and EXO (Enriched Xenon Observatory)-200 experiments) have established the lifetime of this decay to be longer than 10^(25) years, corresponding to a limit on the neutrino mass of 0.2–0.4 electronvolts. Here we report new results from EXO-200 based on a large ^(136)Xe exposure that represents an almost fourfold increase from our earlier published data sets. We have improved the detector resolution and revised the data analysis. The half-life sensitivity we obtain is 1.9 × 10^(25) years, an improvement by a factor of 2.7 on previous EXO-200 results. We find no statistically significant evidence for 0νββ decay and set a half-life limit of 1.1 × 10^(25)  years at the 90 per cent confidence level. The high sensitivity holds promise for further running of the EXO-200 detector and future 0νββ decay searches with an improved Xe-based experiment, nEXO

    Year in review 2005: Critical Care – Respirology: mechanical ventilation, infection, monitoring, and education

    Get PDF
    We summarize all original research in the field of respiratory intensive care medicine published in 2005 in Critical Care. Twenty-seven articles were grouped into the following categories and subcategories to facilitate rapid overview: mechanical ventilation (physiology, spontaneous breathing during mechanical ventilation, high frequency oscillatory ventilation, side effects of mechanical ventilation, sedation, and prone positioning); infection (pneumonia and sepsis); monitoring (ventilatory monitoring, pulmonary artery catheter and pulse oxymeter); and education (training and health outcome)
    • …
    corecore