150 research outputs found
Feigenbaum scenario without parameters
Typically, the period-doubling bifurcations exhibited by nonlinear
dissipative systems are observed when varying systems' parameters. In contrast,
the period-doubling bifurcations considered in the current research are induced
by changing the initial conditions whereas parameter values are fixed. Thus,
the studied bifurcations can be classified as the period-doubling bifurcations
without parameters. Moreover, we show a cascade of the period-doubling
bifurcations without parameters resulting in transition to deterministic chaos.
The explored effects are demonstrated by means of numerical modelling on an
example of a modified Anishchenko-Astakhov self-oscillator where the ability to
exhibit bifurcations without parameters is associated with the properties of a
memristor. Finally, we compare the dynamics of the ideal-memristor-based
oscillator with the behaviour of a model taking into account the memristor
forgetting effect.Comment: 9 pages, 5 figure
Triple GEM Tracking Detectors for the BM@N Experiment
BM@N (Baryonic Matter at the Nuclotron) is the fixed target experiment aimed to study nuclear matter in the relativistic heavy ion collisions at the Nuclotron accelerator in JINR. The BM@N tracking system is based on Gas Electron Multipliers (GEM) detectors, mounted inside the BM@N analyzing magnet. The structure of the GEM detectors and the results of study of their characteristics are presented. The GEM detectors are integrated into the BM@N experimental setup and data acquisition system. The results of the first test of the GEM tracking system in the technical run with the deuteron beam are shortly reviewed
New insight into the low-energy He spectrum
The spectrum of He was studied by means of the He(,)He
reaction at a lab energy of 25 MeV/n and small center of mass (c.m.) angles.
Energy and angular correlations were obtained for the He decay products by
complete kinematical reconstruction. The data do not show narrow states at
1.3 and 2.4 MeV reported before for He. The lowest resonant
state of He is found at about 2 MeV with a width of 2 MeV and is
identified as . The observed angular correlation pattern is uniquely
explained by the interference of the resonance with a virtual state
(limit on the scattering length is obtained as fm), and with
the resonance at energy MeV.Comment: 5 pages, 4 figures, 2 table
10He low-lying states structure uncovered by correlations
The 0+ ground state of the 10He nucleus produced in the 3H(8He,p)10He
reaction was found at about MeV (\Gamma ~ 2 MeV) above the
three-body 8He+n+n breakup threshold. Angular correlations observed for 10He
decay products show prominent interference patterns allowing to draw
conclusions about the structure of low-energy excited states. We interpret the
observed correlations as a coherent superposition of the broad 1- state having
a maximum at energy 4-6 MeV and the 2+ state above 6 MeV, setting both on top
of the 0+ state "tail". This anomalous level ordering indicates that the
breakdown of the N=8 shell known in 12Be thus extends also to the 10He system.Comment: 5 pages, 5 figure
Three-body correlations in direct reactions: Example of Be populated in reaction
The Be continuum states were populated in the charge-exchange reaction
H(Li,Be) collecting very high statistics data ( events) on the three-body ++ correlations. The
Be excitation energy region below MeV is considered, where the
data are dominated by contributions from the and states. It is
demonstrated how the high-statistics few-body correlation data can be used to
extract detailed information on the reaction mechanism. Such a derivation is
based on the fact that highly spin-aligned states are typically populated in
the direct reactions.Comment: submitted to Physical Review
Mitoxantrone Quantification by HPLC-MS/MS in Caco-2 Culture Media
Mitoxantrone is a marker substrate of breast cancer resistance protein (BCRP). BCRP is involved in a number of pharmacokinetic drug-drug interactions. The transporter’s possible saturability makes it advisable to use low concentrations of mitoxantrone for in vitro studies. Consequently, mitoxantrone quantification requires a method with high sensitivity.The aim of the study was to develop and validate a procedure for mitoxantrone quantification in Caco-2 culture media by HPLC-MS/MS.Materials and methods. The authors used an Ultimate 3000 HPLC system and a TSQ Fortis triple quadrupole mass spectrometer by Thermo Fisher Scientific and a Selectra C18 column (4.6×100 mm, 5 μm, 100 Å) by United Chemical Technologies. The elution ran in a gradient mode with a mobile phase of 1% formic acid solution and methanol. Experimental parameters were as follows: eluent flow rate, 0.3 mL/min; separation column temperature, 35 °C; injection volume, 5 μL; ana lysis time, 10 min; approximate mitoxantrone retention time, 5.51 min. The sample preparation involved protein precipitation from the culture medium with methanol, followed by centrifugation at 13,000 g for 10 min. The detection was performed using electrospray ionisation in the positive ion mode. Detection parameters were as follows: electrospray voltage, 3700 V; sheath gas flow rate, 50 L/min; auxiliary gas flow rate, 10 L/min; sweep gas flow rate, 1 L/min; ion-transfer tube temperature, 300 °C; and evaporator temperature, 350 °C. The detection was set at mass transitions of m/z 455 to 88.2 and m/z 455 to 358.1, with the collision energy for these transitions amounting to 25 V and 18 V, respectively. The source fragmentation was at 0, and the CID gas pressure was at 2 mTorr.Results. The analytical procedure showed selectivity, high sensitivity (limit of detection, 10 nmol/L; lower limit of quantification, 50 nmol/L), accuracy, precision, and linearity in the concentration range of 50–1000 nmol/L. The authors observed no carryover or matrix effects. A simulation of real-life storage conditions demonstrated high stability of mitoxantrone samples. Thus, the analytical procedure enables preclinical evaluation of medicinal product effects on the functional activity of BCRP, based on assessing the transcellular mitoxantrone transport in the presence of a test product.Conclusion. The authors developed and validated the analytical procedure for mitoxantrone quantification in Caco-2 culture media by HPLC-MS/MS
\b{eta}-delayed three-proton decay of 31Ar
The beta decay of 31Ar, produced by fragmentation of a 36Ar beam at 880
MeV/nucleon, was investigated. Identified ions of 31Ar were stopped in a
gaseous time projection chamber with optical readout allowing to record decay
events with emission of protons. In addition to \b{eta}-delayed emission of one
and two protons we have clearly observed the beta-delayed three-proton branch.
The branching ratio for this channel in 31Ar is found to be 0.07(2)%.Comment: 5 pages, 3 figures, submitted to Physical Rev.
- …